Experimental investigation on the performance of chilled-water air conditioning unit using alumina nanofluids

被引:27
|
作者
Ahmed, M. Salem [1 ]
Hady, Mohamed R. Abdel [2 ]
Abdallah, G. [3 ]
机构
[1] Sohag Univ, Fac Ind Educ, Sohag, Egypt
[2] Sch Dar Slaam Tech, Sohag, Egypt
[3] Helwan Univ, Fac Ind Educ, Cairo, Egypt
关键词
Nanofluids; Alumina; Chilled water; Air conditioning; Nanotechnology; COP;
D O I
10.1016/j.tsep.2017.07.002
中图分类号
O414.1 [热力学];
学科分类号
摘要
One of the important contributions to the application of nanotechnology is the nanofluids technique in which will be become a good alternative to the conventional heat transfer medium. This is done by addition of nanoparticles of high thermal conductivity to the base fluid of the low thermal conductivity. In the present paper, the performance of chilled-water air conditioning unit with and without alumina nanofluids has been experimentally investigated. The first method technique was used to prepare Al2O3-water nanofluids. Al2O3 nanoparticles was added with water in the cooling tank through using different concentrations by weight varies from 0.1, 0.2, 0.3, and 1% wt. and the alumina nanofluids have been continuously supplied to the cooling coil. The experiments have been performed under operation conditions include a variation of flow rate of chilled water/alumina nanofluids and the air through the cooling coil. The experimental results have been shown a less time is achieved to obtain the desired child fluid temperature for all the different concentrations of nanofluids (Al2O3-water) compared with pure water. Also, the results revealed a reduction of the power consumption and increasing the cooling capacity which in turn increasing the COP by about 5%, and 17% for alumina nanoparticles concentration 0.1, and 1% by weight respectively. (C) 2017 Published by Elsevier Ltd.
引用
收藏
页码:589 / 596
页数:8
相关论文
共 50 条
  • [1] Design of a chilled-water storage unit for solar air-conditioning
    Serag-Eldin, M. A.
    [J]. INTERNATIONAL JOURNAL OF SUSTAINABLE ENERGY, 2013, 32 (05) : 385 - 405
  • [2] Experimental investigation of a stratified chilled-water thermal storage system
    Karim, M. A.
    [J]. APPLIED THERMAL ENGINEERING, 2011, 31 (11-12) : 1853 - 1860
  • [3] Effect of hybrid and single nanofluids on the performance characteristics of chilled water air conditioning system
    Ahmed, M. Salem
    Elsaid, Ashraf Mimi
    [J]. APPLIED THERMAL ENGINEERING, 2019, 163
  • [4] A Virtual Chilled-Water Flow Meter Development at Air Handling Unit Level
    Swamy, Atul
    Song, Li
    Wang, Gang
    [J]. ASHRAE TRANSACTIONS 2012, VOL 118, PT 1, 2012, 118 : 1013 - 1020
  • [5] Energy-saving Technique Targeting Chilled-water Air Conditioning Equipment in Data Centers
    Nakata, Tatsuya
    Kaneko, Shinichiro
    Yoshii, Ari
    Sekiguchi, Keisuke
    Yanagi, Masahide
    [J]. 2014 IEEE 36TH INTERNATIONAL TELECOMMUNICATIONS ENERGY CONFERENCE (INTELEC), 2014,
  • [7] Parametric investigation of a chilled water district cooling unit using mono and hybrid nanofluids
    Eric C. Okonkwo
    Tareq Al-Ansari
    [J]. Scientific Reports, 11
  • [8] Parametric investigation of a chilled water district cooling unit using mono and hybrid nanofluids
    Okonkwo, Eric C.
    Al-Ansari, Tareq
    [J]. SCIENTIFIC REPORTS, 2021, 11 (01)
  • [9] Experimental study on desiccant evaporative combined chilled air/chilled water air conditioning systems
    Chen, Liu
    Deng, Wenjie
    Chu, Yujie
    [J]. APPLIED THERMAL ENGINEERING, 2021, 199
  • [10] Performance Monitoring of Chilled-Water Distribution Systems Using HVAC-Cx
    Ferretti, Natascha Milesi
    Galler, Michael A.
    Bushby, Steven T.
    [J]. ASHRAE TRANSACTIONS 2017, VOL 123, PT 2, 2017, 123 : 53 - 63