EVALUATION OF OXYGEN-SATURATION MONITORING BY PULSE OXIMETRY IN NEONATES IN THE DELIVERY SYSTEM

被引:65
|
作者
DIMICH, I
SINGH, PP
ADELL, A
HENDLER, M
SONNENKLAR, N
JHAVERI, M
机构
[1] MT SINAI MED SCH,DEPT ANESTHESIOL,NEW YORK,NY
[2] CITY HOSP CTR,ELMHURST,NY 11373
关键词
ANESTHESIA; -; OBSTETRICAL; NEONATES; MEASUREMENT TECHNIQUES - OXIMETERS; MONITORING; OXYGEN; OXYGEN - BLOOD LEVELS; MEASUREMENT;
D O I
10.1007/BF03008616
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The pulse oximeter was evaluated for use in neonates in the delivery room. One hundred neonates, delivered vaginally or by Caesarean section with general or epidural anaesthesia, were studied. After delivery, pulse oximetry probes were placed simultaneously on the ulnar side of the right hand and on the right Achilles tendon to determine whether there was a difference in arterial oxygenation (SpO2). Measurements of SpO2 were taken at 1, 5, 10 min, and 24 hr after delivery. At one and five minutes, SpO2 recorded from the right hand was higher than that recorded from the lower extremities (71.9% +/- 6.5% vs 63.4% +/- 4.3% and 83.3% +/- 4.2% vs 76% +/- 4.1%, mean +/- SD, respectively). At ten minutes these differences diminished, and had almost completely disappeared after 24 hr. These results can be explained by the presence of R-L shunting at the ductus arteriosus level, producing reduced SaO2 in the lower extremities. Oxygen saturation did not differ between neonates delivered vaginally or by Caesarean section, regardless of the presence or type of anaesthesia. We concluded that neonates remain relatively desaturated in the immediate postpartum period and that the SpO2 obtained from the right hand is a better index of neonatal oxygenation than that obtained from the heel.
引用
收藏
页码:985 / 988
页数:4
相关论文
共 50 条
  • [41] Meta-analysis of arterial oxygen saturation monitoring by pulse oximetry in adults
    Jensen, LA
    Onyskiw, JE
    Prasad, NGN
    HEART & LUNG, 1998, 27 (06): : 387 - 408
  • [42] PULSE OXIMETRY IN SICK PREMATURE-INFANTS AND THE EFFECTS OF PHOTOTHERAPY AND RADIANT WARMERS ON THE OXYGEN-SATURATION READOUT
    ZUBROW, AB
    HENDERSON, GW
    IMAIZUMI, SO
    PLEASURE, JR
    AMERICAN JOURNAL OF PERINATOLOGY, 1990, 7 (01) : 75 - 78
  • [43] Novel Pulse Oximetry Sonifications for Neonatal Oxygen Saturation Monitoring: A Laboratory Study
    Hinckfuss, Kelly
    Sanderson, Penelope
    Loeb, Robert G.
    Liley, Helen G.
    Liu, David
    HUMAN FACTORS, 2016, 58 (02) : 344 - 359
  • [44] Pulse Oximetry Overestimates Oxygen Saturation in COPD
    Amalakanti, Sridhar
    Pentakota, Mohan Rao
    RESPIRATORY CARE, 2016, 61 (04) : 423 - 427
  • [45] Oxygen Saturation in Pulse Oximetry in Hemoglobin Anomalies
    Zur, B.
    Bagci, S.
    Ludwig, M.
    Stoffel-Wagner, B.
    KLINISCHE PADIATRIE, 2012, 224 (04): : 259 - 265
  • [46] Effect of exchange blood transfusion on oxygen saturation of neonates with severe neonatal jaundice by pulse oximetry
    Shakur, Abubakar Muhammed
    Garba, Nuhu Abubakar
    Ahmadu, Ibrahim
    Apollos, Daniel
    Wada, Aminu
    Abdullahil, Safiya Garba
    Mohammed, Abdulsalam
    Asani, Mustafa O.
    Aliyu, Ibrahim
    JOURNAL OF ACUTE DISEASE, 2021, 10 (03) : 112 - 116
  • [47] CHARACTERISATION OF OXYGEN SATURATION IN HEALTHY SLEEPING NEONATES USING HIGH TEMPORAL RESOLUTION PULSE OXIMETRY
    Mason, D. G.
    Parsley, C. L.
    Wilson, S. J.
    Dakin, C. J.
    SLEEP, 2010, 33 : A316 - A317
  • [48] CONTINUOUS MONITORING OF CEREBRAL HEMOGLOBIN OXYGEN-SATURATION
    BROWN, RW
    INTERNATIONAL ANESTHESIOLOGY CLINICS, 1993, 31 (03) : 141 - 158
  • [49] POSTOPERATIVE MIXED VENOUS OXYGEN-SATURATION MONITORING
    BARON, JF
    BENSOUDA, A
    CORIAT, P
    ACP-APPLIED CARDIOPULMONARY PATHOPHYSIOLOGY, 1988, 2 (04): : 327 - 332
  • [50] MONITORING OF CENTRAL VENOUS OXYGEN-SATURATION VERSUS MIXED VENOUS OXYGEN-SATURATION IN CRITICALLY ILL PATIENTS
    MARTIN, C
    AUFFRAY, JP
    BADETTI, C
    PERRIN, G
    PAPAZIAN, L
    GOUIN, F
    INTENSIVE CARE MEDICINE, 1992, 18 (02) : 101 - 104