EVALUATION OF OXYGEN-SATURATION MONITORING BY PULSE OXIMETRY IN NEONATES IN THE DELIVERY SYSTEM

被引:65
|
作者
DIMICH, I
SINGH, PP
ADELL, A
HENDLER, M
SONNENKLAR, N
JHAVERI, M
机构
[1] MT SINAI MED SCH,DEPT ANESTHESIOL,NEW YORK,NY
[2] CITY HOSP CTR,ELMHURST,NY 11373
关键词
ANESTHESIA; -; OBSTETRICAL; NEONATES; MEASUREMENT TECHNIQUES - OXIMETERS; MONITORING; OXYGEN; OXYGEN - BLOOD LEVELS; MEASUREMENT;
D O I
10.1007/BF03008616
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The pulse oximeter was evaluated for use in neonates in the delivery room. One hundred neonates, delivered vaginally or by Caesarean section with general or epidural anaesthesia, were studied. After delivery, pulse oximetry probes were placed simultaneously on the ulnar side of the right hand and on the right Achilles tendon to determine whether there was a difference in arterial oxygenation (SpO2). Measurements of SpO2 were taken at 1, 5, 10 min, and 24 hr after delivery. At one and five minutes, SpO2 recorded from the right hand was higher than that recorded from the lower extremities (71.9% +/- 6.5% vs 63.4% +/- 4.3% and 83.3% +/- 4.2% vs 76% +/- 4.1%, mean +/- SD, respectively). At ten minutes these differences diminished, and had almost completely disappeared after 24 hr. These results can be explained by the presence of R-L shunting at the ductus arteriosus level, producing reduced SaO2 in the lower extremities. Oxygen saturation did not differ between neonates delivered vaginally or by Caesarean section, regardless of the presence or type of anaesthesia. We concluded that neonates remain relatively desaturated in the immediate postpartum period and that the SpO2 obtained from the right hand is a better index of neonatal oxygenation than that obtained from the heel.
引用
收藏
页码:985 / 988
页数:4
相关论文
共 50 条
  • [31] COMPARISON OF OXYGEN-SATURATION BY PULSE OXIMETER AND ARTERIAL BLOOD-GAS CO-OXIMETRY
    BERLIN, SL
    CRAPO, RO
    JENSEN, RL
    [J]. CLINICAL RESEARCH, 1989, 37 (01): : A163 - A163
  • [32] Reflectance pulse oximetry from core body in neonates and infants: Comparison to arterial blood oxygen saturation and to transmission pulse oximetry
    Kugelman A.
    Wasserman Y.
    Mor F.
    Goldinov L.
    Geller Y.
    Bader D.
    [J]. Journal of Perinatology, 2004, 24 (6) : 366 - 371
  • [33] JUGULAR VENOUS OXYGEN-SATURATION MONITORING
    CRUZ, J
    [J]. JOURNAL OF NEUROSURGERY, 1992, 77 (01) : 162 - 163
  • [34] AMBULATORY MONITORING OF ARTERIAL OXYGEN-SATURATION
    DECKER, MJ
    HOEKJE, PL
    STROHL, KP
    [J]. CHEST, 1989, 95 (04) : 717 - 722
  • [35] OXYGEN-SATURATION MONITORING DURING ENDOSCOPY
    STEFFES, CP
    SUGAWA, C
    WILSON, RF
    HAYWARD, SR
    [J]. SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1990, 4 (03): : 175 - 178
  • [36] MONITORING ARTERIAL OXYGEN-SATURATION IN THE NEONATE
    DECKARDT, R
    SCHNEIDER, KTM
    GRAEFF, H
    [J]. JOURNAL OF PERINATAL MEDICINE, 1987, 15 (04) : 357 - 360
  • [37] OXYGEN-SATURATION MONITORING DURING ENDOSCOPY
    STEFFES, CP
    SUGAWA, C
    WILSON, RF
    HAYWARD, SR
    NAKAMURA, R
    [J]. GASTROINTESTINAL ENDOSCOPY, 1989, 35 (02) : 191 - 191
  • [38] OXYGEN-SATURATION IN PREMATURE NEONATES WITH BRONCHOPULMONARY DYSPLASIA IN A HAMMOCK
    ZANARDO, V
    TREVISANUTO, D
    DANI, C
    BOTTOS, M
    GUGLIELMI, A
    CANTARUTTI, F
    [J]. BIOLOGY OF THE NEONATE, 1995, 67 (01): : 54 - 58
  • [39] PULSE OXIMETRY FAILS TO ACCURATELY DETECT LOW-LEVELS OF ARTERIAL HEMOGLOBIN OXYGEN-SATURATION IN DOGS
    SIDI, A
    RUSH, W
    GRAVENSTEIN, N
    RUIZ, B
    PAULUS, DA
    DAVIS, RF
    [J]. JOURNAL OF CLINICAL MONITORING, 1987, 3 (04): : 257 - 262
  • [40] PULSE OXIMETRY USED FOR DOCUMENTING OXYGEN-SATURATION AND RIGHT-TO-LEFT SHUNTING IMMEDIATELY AFTER BIRTH
    MEIERSTAUSS, P
    BUCHER, HU
    HURLIMANN, R
    KONIG, V
    HUCH, R
    [J]. EUROPEAN JOURNAL OF PEDIATRICS, 1990, 149 (12) : 851 - 855