A FUNDAMENTAL LIMIT ON TIMING PERFORMANCE WITH SCINTILLATION DETECTORS

被引:21
|
作者
CLINTHORNE, NH [1 ]
PETRICK, NA [1 ]
ROGERS, WL [1 ]
HERO, AO [1 ]
机构
[1] UNIV MICHIGAN,DEPT ELECT ENGN & COMP SCI,ANN ARBOR,MI 48109
关键词
D O I
10.1109/23.106694
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A new lower bound on the mean-squared error of post-detection γ-ray time-of-flight estimators has been derived. Previously, the Cramer-Rao bound has been applied, but for nearly exponentially decaying scintillation pulses it gives an extremely optimistic picture of the achievable performance, depending critically on the dark current and photomultiplier characteristics. The new bound has been derived under the assumption that excited states in the scintillator leading to the emission of scintillation photons have an exponential lifetime density. The bound is a function of the mean state lifetime, the spectrum of energy deposited, and the energy conversion efficiency of the scintillator, and is exact for the observation of a mono-exponentially decaying photo-electron rate at the first dynode of the PMT given the γ-ray arrival time. Copyright © 1990 by The Institute of Electrical and Electronics Engineers, Inc.
引用
收藏
页码:658 / 663
页数:6
相关论文
共 50 条
  • [31] Energy resolution improvement of NaI(Tl) scintillation detectors by means of a timing discrimination method
    Celiktas, C.
    Ermis, E. E.
    Bayburt, M.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2012, 293 (01) : 377 - 382
  • [32] Energy resolution improvement of NaI(Tl) scintillation detectors by means of a timing discrimination method
    C. Celiktas
    E. E. Ermis
    M. Bayburt
    Journal of Radioanalytical and Nuclear Chemistry, 2012, 293 : 377 - 382
  • [33] A discussion of the fundamental limit of performance of an electron microscope
    Hillier, J
    PHYSICAL REVIEW, 1941, 60 (10): : 743 - 745
  • [34] Measurement of coincidence timing resolution of scintillation detectors compared to semiconductor detectors to image three-photon positron annihilation
    Abuelhia, E.
    Alzimami, K.
    Alkhorayef, M.
    Podolyak, Z.
    Spyrou, N. M.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2008, 278 (03) : 767 - 771
  • [35] Measurement of coincidence timing resolution of scintillation detectors compared to semiconductor detectors to image three-photon positron annihilation
    E. Abuelhia
    K. Alzimami
    M. Alkhorayef
    Z. Podolyák
    N. M. Spyrou
    Journal of Radioanalytical and Nuclear Chemistry, 2008, 278 : 767 - 771
  • [36] ON STABILITY OF SCINTILLATION DETECTORS
    ABRAHAMSON, H
    BRANDT, R
    GULLQUIST, R
    STRANDELL, T
    JOURNAL OF NUCLEAR MEDICINE, 1981, 22 (09) : 824 - 826
  • [37] RESONANCE SCINTILLATION DETECTORS
    DOLENKO, AV
    EGIAZARO.BG
    RAIKHMAN, EM
    PRIBORY I TEKHNIKA EKSPERIMENTA, 1974, (01): : 58 - 60
  • [38] IONIZATION SCINTILLATION DETECTORS
    POLICARPO, AJPL
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 196 (01): : 53 - 62
  • [39] FUNDAMENTAL MECHANISMS DETERMINING THE PERFORMANCE OF GAS PROPORTIONAL DETECTORS
    SVENSSON, A
    ALLAN, RJ
    BORDAS, J
    HUGHES, EA
    LEWIS, R
    MANT, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1994, 88 (04): : 465 - 469
  • [40] Generation-Recombination Noise: The Fundamental Sensitivity Limit for Kinetic Inductance Detectors
    P. J. de Visser
    J. J. A. Baselmans
    P. Diener
    S. J. C. Yates
    A. Endo
    T. M. Klapwijk
    Journal of Low Temperature Physics, 2012, 167 : 335 - 340