REGION-OF-INTEREST (ROI) MODE IN INDUSTRIAL X-RAY COMPUTED-TOMOGRAPHY

被引:0
|
作者
REIMERS, P
KETTSCHAU, A
GOEBBELS, J
机构
来源
NDT INTERNATIONAL | 1990年 / 23卷 / 05期
关键词
X-RAY; TOMOGRAPHY; REGION-OF-INTEREST; REFERENCE DATA SET;
D O I
10.1016/0963-8695(90)90001-Y
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In contrast to medical CT where ROI-methods have been discussed from the point of view of lowering the radiation burden of the patient, industrial CT can profit from ROI-methods with respect to shorter measuring and computing time. Three methods of ROI-image reconstruction are discussed, all based on the assumption of having gained the out-of-ROI data of each profile with poor resolution and precision. The experiments show that for the ROI-image no deterioration is caused by reduced data sets for the out-of-ROI range, either for coarse sampled data or lower dynamic range of the detector.
引用
收藏
页码:255 / 261
页数:7
相关论文
共 50 条
  • [1] Analysis of iterative region-of-interest image reconstruction for x-ray computed tomography
    Sidky, Emil Y.
    Kraemer, David N.
    Roth, Erin G.
    Ullberg, Christer
    Reiser, Ingrid S.
    Pan, Xiaochuan
    [J]. JOURNAL OF MEDICAL IMAGING, 2014, 1 (03)
  • [2] Region-of-interest (ROI) computed tomography: Combining dual resolution XRII images
    Chityala, R
    Hoffmann, K
    Rudin, S
    Bednarek, D
    [J]. MEDICAL PHYSICS, 2005, 32 (06) : 2056 - 2056
  • [3] CHARACTERISTICS OF A SILICON DETECTOR FOR INDUSTRIAL X-RAY COMPUTED-TOMOGRAPHY
    MIYAI, H
    KITAGUCHI, H
    KAWASAKI, S
    IZUMI, S
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 353 (1-3): : 97 - 100
  • [4] Region of interest (ROI) computed tomography
    Chityala, R
    Hoffmann, KR
    Bednarek, DR
    Rudin, S
    [J]. MEDICAL IMAGING 2004: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2004, 5368 : 534 - 541
  • [5] Region of interest reconstruction in x-ray fluorescence computed tomography
    La Riviere, Patrick J.
    Vargas, Phillip
    Xia, Dan
    Pan, Xiaochuan
    [J]. DEVELOPMENTS IN X-RAY TOMOGRAPHY VI, 2008, 7078
  • [6] A new antiscatter grid for high-resolution region-of-interest (ROI) x-ray imaging
    Yadava, G.
    Rudin, S.
    Kuhls, A.
    Bednarek, D.
    [J]. MEDICAL PHYSICS, 2007, 34 (06) : 2563 - 2563
  • [7] Truncation Correction for X-ray Phase-Contrast Region-of-Interest Tomography
    Felsner, Lina
    Kaeppler, Sebastian
    Maier, Andreas
    Riess, Christian
    [J]. IEEE TRANSACTIONS ON COMPUTATIONAL IMAGING, 2020, 6 : 625 - 639
  • [8] X-ray micro computed-tomography
    Baird, Emily
    Taylor, Gavin
    [J]. CURRENT BIOLOGY, 2017, 27 (08) : R289 - R291
  • [9] APPLIED X-RAY COMPUTED-TOMOGRAPHY
    BUYNAK, CF
    BOSSI, RH
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1995, 99 (1-4): : 772 - 774
  • [10] DEVELOPMENT OF INDUSTRIAL X-RAY COMPUTED-TOMOGRAPHY AND ITS APPLICATION TO REFRACTORIES
    AIBA, Y
    OKI, K
    NAKAMURA, S
    FUJII, M
    [J]. TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 1985, 71 (14): : 1692 - 1699