CHARACTERISTICS OF A SILICON DETECTOR FOR INDUSTRIAL X-RAY COMPUTED-TOMOGRAPHY

被引:3
|
作者
MIYAI, H
KITAGUCHI, H
KAWASAKI, S
IZUMI, S
机构
[1] Energy Research Laboratory, Hitachi Ltd., Hitachi-shi, Ibaraki-ken, 319-12
关键词
D O I
10.1016/0168-9002(94)91611-X
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We have evaluated a silicon solid state detector (Si-SSD) as a detector for Industrial X-ray Computed Tomography (IXCT) from the viewpoints of sensitivity and radiation damage. The detector which we used in this work, is a diffused junction type Si-SSD (43 X 3.8 X 0.5 mm) fabricated on high purity n-type silicon. We measured pulse height distributions for narrow pencil beam Co-60 gamma rays parallelly incident to the detector. The expected deposit energy was 0.146 +/- 0.001 MeV (11.7% of the incident photon energy). The calculated pulse height distribution using the general purpose EGS4 code was confirmed to be in good agreement with the measured one. The radiation damage was evaluated using the Co-60 gamma ray source. Exposure of up to 88 kGy(Si) was achieved over a period of 20 hours, with an exposure rate of 4.4 kGy(Si)/h (36 mC/kg s). It was confirmed that the Si-SSDs could be used at least up to 88 kGy(Si) with X-rays equivalent to Co-60 gamma rays.
引用
收藏
页码:97 / 100
页数:4
相关论文
共 50 条
  • [1] RESPONSE OF SILICON DETECTOR FOR HIGH-ENERGY X-RAY COMPUTED-TOMOGRAPHY
    MIYAI, H
    KAWASAKI, S
    KITAGUCHI, H
    IZUMI, S
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (04) : 999 - 1003
  • [2] X-ray micro computed-tomography
    Baird, Emily
    Taylor, Gavin
    [J]. CURRENT BIOLOGY, 2017, 27 (08) : R289 - R291
  • [3] APPLIED X-RAY COMPUTED-TOMOGRAPHY
    BUYNAK, CF
    BOSSI, RH
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1995, 99 (1-4): : 772 - 774
  • [4] DEVELOPMENT OF INDUSTRIAL X-RAY COMPUTED-TOMOGRAPHY AND ITS APPLICATION TO REFRACTORIES
    AIBA, Y
    OKI, K
    NAKAMURA, S
    FUJII, M
    [J]. TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 1985, 71 (14): : 1692 - 1699
  • [5] DEVELOPMENT OF INDUSTRIAL X-RAY COMPUTED-TOMOGRAPHY AND ITS APPLICATION TO REFRACTORIES
    AIBA, Y
    OKI, K
    MATSUURA, S
    FUJII, M
    [J]. TRANSACTIONS OF THE IRON AND STEEL INSTITUTE OF JAPAN, 1986, 26 (03) : 236 - 243
  • [6] HIGH-ENERGY X-RAY COMPUTED-TOMOGRAPHY FOR INDUSTRIAL APPLICATIONS
    IZUMI, S
    KAMATA, S
    SATOH, K
    MIYAI, H
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (02) : 158 - 161
  • [7] Industrial X-ray computed tomography
    Pechstein, Torsten
    [J]. TM-TECHNISCHES MESSEN, 2020, 87 (02) : 79 - 80
  • [8] Industrial computed X-ray tomography
    Luthi, T
    Flisch, A
    Wyss, P
    [J]. INSIGHT, 1998, 40 (03) : 196 - 197
  • [9] TENDERING FOR AN X-RAY COMPUTED-TOMOGRAPHY SCANNER
    EDYVEAN, S
    PERRY, BJ
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1987, 60 (716): : 834 - 834
  • [10] CERAMIC SCINTILLATORS FOR X-RAY COMPUTED-TOMOGRAPHY
    GRABMAIER, BC
    ROSSNER, W
    LEPPERT, J
    [J]. PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE, 1992, 130 (02): : K183 - K187