NSLS X1B - AN UNDULATOR BEAMLINE FOR HIGH-RESOLUTION SOFT-X-RAY SPECTROSCOPY

被引:17
|
作者
RANDALL, KJ
EBERHARDT, W
FELDHAUS, J
ERLEBACH, W
BRADSHAW, AM
XU, Z
JOHNSON, PD
MA, Y
机构
[1] PACIFIC NW LAB, MSRC, RICHLAND, WA 99352 USA
[2] BROOKHAVEN NATL LAB, DEPT PHYS, UPTON, NY 11973 USA
[3] EXXON CORP RES LABS, FLORHAM PK, NJ 07932 USA
[4] FORSCHUNGSZENTRUM JULICH, W-5170 JULICH 1, GERMANY
关键词
D O I
10.1016/0168-9002(92)90538-F
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The X1 undulator on the X-ray ring of the NSLS at Brookhaven is an extremely bright source of soft X-ray photons. On the recently completed spectroscopy beamline X1B we have attempted to utilise the intrinsically narrow beam size and divergence to maximise the intensity throughput in a spherical grating monochromator (SGM). The high power density of the undulator radiation requires the use of water cooled mirrors, entrance slit and grating. Calculations predict that simple side cooled copper pads attached to optical elements will be sufficiently effective that resolution degradation due to thermal deformation of figure error will be negligible in the SGM design. This is confirmed by attainment of resolution superior to other SGMs and the BESSY SX700-II monochromator over the energy range 300-540 eV (C1s-1, N1s-1 and O1s-1). At a resolution comparable to the best so far obtained for the nitrogen N1s-pi* excitation (401 eV) on other monochromators we have demonstrated an intensity increase, at the sample, of more than three orders of magnitude. The design considerations upon which beamline X1B is based are highly relevant to thc construction of soft X-ray monochromators at future synchrotron radiation sources such as the ALS (Berkeley), Elettra (Trieste) and BESSYII (Berlin).
引用
收藏
页码:101 / 105
页数:5
相关论文
共 50 条
  • [21] THE HIGH-RESOLUTION PHOTOSPHERIC SOFT-X-RAY SPECTRUM OF SIRIUS-B
    PAERELS, FBS
    BLEEKER, JAM
    BRINKMAN, AC
    HEISE, J
    ASTROPHYSICAL JOURNAL, 1988, 329 (02): : 849 - 862
  • [22] HIGH-RESOLUTION SOFT-X-RAY MONOCHROMATORS OF NEW DESIGN
    BONFANTE, G
    NALETTO, G
    TONDELLO, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 291 (1-2): : 213 - 218
  • [23] THE HIGH-RESOLUTION SOFT-X-RAY SPECTRUM OF HZ 43
    PAERELS, FBS
    BLEEKER, JAM
    BRINKMAN, AC
    GRONENSCHILD, EHBM
    HEISE, J
    ASTROPHYSICAL JOURNAL, 1986, 308 (01): : 190 - 198
  • [24] CONFERENCE SUMMARY - HIGH-RESOLUTION SOFT-X-RAY OPTICS
    FRANKS, A
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1981, 316 : 211 - 213
  • [25] Soft x-ray spectroscopy undulator beamline at the Advanced Photon Source
    Randall, KJ
    Xu, ZD
    Moore, JF
    Gluskin, E
    GRATINGS AND GRATING MONOCHROMATORS FOR SYNCHROTRON RADIATION, 1997, 3150 : 189 - 194
  • [26] Beamline I311 at MAX-LAB: a VUV/soft X-ray undulator beamline for high resolution electron spectroscopy
    Nyholm, R
    Andersen, JN
    Johansson, U
    Jensen, BN
    Lindau, I
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 : 520 - 524
  • [27] A DEDICATED SOFT-X-RAY XAS BEAMLINE
    MORRISON, TI
    LIEN, NC
    SAYERS, DE
    HEALD, SM
    FARERIA, L
    SCROFANI, J
    PHYSICA B, 1989, 158 (1-3): : 330 - 331
  • [28] PERFORMANCE OF THE DRAGON SOFT-X-RAY BEAMLINE
    CHEN, CT
    SETTE, F
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07): : 1616 - 1621
  • [29] A NOVEL DESIGN FOR A HIGH-RESOLUTION SOFT-X-RAY CRYSTAL SPECTROMETER
    WATSON, LM
    NORRIS, PR
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1982, 15 (01): : 105 - 107
  • [30] SOFT-X-RAY SPECTROSCOPY
    URCH, DS
    JOURNAL DE PHYSIQUE III, 1994, 4 (09): : 1613 - 1623