Soft x-ray spectroscopy undulator beamline at the Advanced Photon Source

被引:0
|
作者
Randall, KJ
Xu, ZD
Moore, JF
Gluskin, E
机构
关键词
D O I
10.1117/12.292732
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Construction of the high-resolution soft x-ray spectroscopy undulator beamline, 2ID-C, at the Advanced Photon Source (APS) has been completed. The beamline, one of two soft x-ray beamlines at the APS, will cover the photon energy range from 500 to 3000 eV, with a maximum resolving power between 7,000 and 14,000. The optical design is based on a spherical grating monochromator (SGM) giving both high resolution and high flux throughput. Photon flux is calculated to be approximately 10(12)-10(13) photons per second with a beam size of approximately 1 x 1 mm(2) at the sample.
引用
收藏
页码:189 / 194
页数:6
相关论文
共 50 条
  • [1] Characterization of the X-ray coherence properties of an undulator beamline at the Advanced Photon Source
    Ju, Guangxu
    Highland, Matthew J.
    Thompson, Carol
    Eastman, Jeffrey A.
    Fuoss, Paul H.
    Zhou, Hua
    Dejus, Roger
    Stephenson, G. Brian
    JOURNAL OF SYNCHROTRON RADIATION, 2018, 25 : 1036 - 1047
  • [2] Optical design of the Short Pulse Soft X-ray Spectroscopy beamline at the Advanced Photon Source
    Reininger, R.
    Keavney, D. J.
    Borland, M.
    Young, L.
    JOURNAL OF SYNCHROTRON RADIATION, 2013, 20 : 654 - 659
  • [3] UNDULATOR SOURCE BEAMLINE FOR SOFT X-RAY IMAGING.
    Rarback, H.
    Krinsky, S.
    Mortazavi, P.
    Shu, D.
    Kirz, J.
    Jacobsen, C.
    Howells, M.
    Nuclear instruments and methods in physics research, 1985, A246 (1-3): : 159 - 162
  • [4] Commissioning of the Soft X-ray Undulator Beamline at the Siam Photon Laboratory
    Nakajima, Hideki
    Chaichuay, Sarunyu
    Sudmuang, Porntip
    Rattanasuporn, Surachet
    Jenpiyapong, Watcharapon
    Supruangnet, Ratchadaporn
    Chanlek, Narong
    Songsiriritthigul, Prayoon
    PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI2015), 2016, 1741
  • [5] Soft x-ray undulator for the Siam Photon Source
    Rugmai, S.
    Dasri, T.
    Prawanta, S.
    Siriwattanapaitoon, S.
    Kwankasem, A.
    Sooksrimuang, V.
    Chachai, W.
    Suradet, N.
    Juthong, N.
    Tancharakorn, S.
    SYNCHROTRON RADIATION INSTRUMENTATION, PTS 1 AND 2, 2007, 879 : 335 - +
  • [6] Characterization of soft X-ray undulator for the Siam Photon Source
    Dasri, T.
    Siriwattanapaitoon, S.
    Chachai, W.
    Rugmai, S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 582 (01): : 40 - 42
  • [7] A soft X-ray undulator beamline at the advanced light source with circular and variable linear polarization for the spectroscopy and microscopy of magnetic materials
    Young, AT
    Arenholz, E
    Feng, J
    Padmore, H
    Marks, S
    Schlueter, R
    Hoyer, E
    Kelez, N
    Steier, C
    SURFACE REVIEW AND LETTERS, 2002, 9 (01) : 549 - 554
  • [8] AN UNDULATOR SOURCE BEAMLINE FOR SOFT-X-RAY IMAGING
    RARBACK, H
    KRINSKY, S
    MORTAZAVI, P
    SHU, D
    KIRZ, J
    JACOBSEN, C
    HOWELLS, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 246 (1-3): : 159 - 162
  • [9] MULTIPLE STATION BEAMLINE AT AN UNDULATOR X-RAY SOURCE
    ALSNIELSEN, J
    FREUND, AK
    GRUBEL, G
    LINDERHOLM, J
    NIELSEN, M
    DELRIO, MS
    SELLSCHOP, JPF
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1994, 94 (03): : 306 - 318
  • [10] SOFT-X-RAY MICROSCOPE AT THE UNDULATOR BEAMLINE OF THE PHOTON FACTORY
    KAGOSHIMA, Y
    AOKI, S
    KAKUCHI, M
    SEKIMOTO, M
    MAEZAWA, H
    HYODO, K
    ANDO, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07): : 2448 - 2451