Optical design of the Short Pulse Soft X-ray Spectroscopy beamline at the Advanced Photon Source

被引:2
|
作者
Reininger, R. [1 ]
Keavney, D. J. [1 ]
Borland, M. [1 ]
Young, L. [1 ]
机构
[1] Argonne Natl Lab, Adv Photon Source, Argonne, IL 60439 USA
关键词
picosecond X-ray pulses; soft X-ray beamline; time-resolved spectroscopy; VLS grating; SYNCHROTRON-RADIATION;
D O I
10.1107/S0909049513013149
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The Short Pulse X-ray facility planned for the Advanced Photon Source (APS) upgrade will provide two sectors with photon beams having picosecond pulse duration. The Short Pulse Soft X-ray Spectroscopy (SPSXS) beamline will cover the 150-2000 eV energy range using an APS bending magnet. SPSXS is designed to take full advantage of this new timing capability in addition to providing circular polarized radiation. Since the correlation between time and electron momentum is in the vertical plane, the monochromator disperses in the horizontal plane. The beamline is designed to maximize flux and preserve the time resolution by minimizing the number of optical components. The optical design allows the pulse duration to be varied from 1.5 to 100 ps full width at half-maximum (FWHM) without affecting the energy resolution, and the resolution to be changed with minimal effect on the pulse duration. More than 10(9) photons s(-1) will reach the sample with a resolving power of 2000 and a pulse duration of similar to 2 ps for photon energies between 150 and 1750 eV. The spot size expected at the sample position will vary with pulse duration and exit slit opening. At 900 eV and at a resolving power of 2000 the spot will be similar to 10 mm x 10 mu m with a pulse duration of 2.3 ps FWHM.
引用
收藏
页码:654 / 659
页数:6
相关论文
共 50 条
  • [1] Soft x-ray spectroscopy undulator beamline at the Advanced Photon Source
    Randall, KJ
    Xu, ZD
    Moore, JF
    Gluskin, E
    GRATINGS AND GRATING MONOCHROMATORS FOR SYNCHROTRON RADIATION, 1997, 3150 : 189 - 194
  • [2] Optical design of the short pulse x-ray imaging and microscopy time-angle correlated diffraction beamline at the Advanced Photon Source
    Reininger, R.
    Dufresne, E. M.
    Borland, M.
    Beno, M. A.
    Young, L.
    Kim, K. -J.
    Evans, P. G.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2013, 84 (05):
  • [3] Design of the Soft X-ray Tomography Beamline at Taiwan Photon Source
    Su, Yi-Jr
    Fu, Huang-Wen
    Chung, Shih-Chun
    Fung, Hok-Sum
    Liu, Din-Goa
    Huang, Liang-Jen
    Yan, Hong-Yi
    Chou, Yu-Ching
    Yin, Gung-Chian
    Lai, Lee-Jene
    PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI2015), 2016, 1741
  • [4] A short-pulse X-ray beamline for spectroscopy and scattering
    Reininger, R.
    Dufresne, E. M.
    Borland, M.
    Beno, M. A.
    Young, L.
    Evans, P. G.
    JOURNAL OF SYNCHROTRON RADIATION, 2014, 21 : 1194 - 1199
  • [5] Optical design of micro-focus X-ray photon correlation spectroscopy beamline at Shenzhen Light Source
    Lei, Tao
    Tan, Yonggen
    Zhang, Zheng
    Chen, Siyuan
    Feng, Jun
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2023, 1048
  • [6] Design of the X-ray Nanoprobe Beamline at the Taiwan Photon Source
    Chang, S. H.
    Yin, G. C.
    Wang, D. J.
    Chang, C. H.
    Juang, J. M.
    Huang, L. J.
    Liu, C. Y.
    Chang, C. F.
    Chu, C. H.
    Tang, M. T.
    11TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI 2012), 2013, 425
  • [7] Soft X-ray microscopy and spectroscopy at the molecular environmental science beamline at the Advanced Light Source
    Bluhm, H
    Andersson, K
    Araki, T
    Benzerara, K
    Brown, GE
    Dynes, JJ
    Ghosal, S
    Gilles, MK
    Hansen, HC
    Hemminger, JC
    Hitchcock, AP
    Ketteler, G
    Kilcoyne, ALD
    Kneedler, E
    Lawrence, JR
    Leppard, GG
    Majzlan, J
    Mun, BS
    Myneni, SCB
    Nilsson, A
    Ogasawara, H
    Ogletree, DF
    Pecher, K
    Salmeron, M
    Shuh, DK
    Tonner, B
    Tyliszczak, T
    Warwick, T
    Yoon, TH
    JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA, 2006, 150 (2-3) : 86 - 104
  • [8] Photon flux measurement of the soft X-ray beamline in Hefei Light Source
    Zhang, Y.X.
    Jiang, S.P.
    Zhang, X.Y.
    Wei, D.Y.
    Xu, S.G.
    He Jishu/Nuclear Techniques, 2001, 24 (07):
  • [9] Beamline Spectroscopy of Integrated Circuits With Hard X-Ray Transition Edge Sensors at the Advanced Photon Source
    Guruswamy, Tejas
    Gades, Lisa
    Miceli, Antonino
    Patel, Umeshkumar
    Quaranta, Orlando
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2021, 31 (05)
  • [10] Short X-ray pulse generation using deflecting cavities at the Advanced Photon Source
    Sajaev, V.
    Borland, M.
    Chae, Y. -C.
    Decker, G.
    Dejus, R.
    Emery, L.
    Harkay, K.
    Nassiri, A.
    Shastri, S.
    Waldschmidt, G.
    Yang, B.
    Anfinrud, P.
    Dolgashev, V.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 582 (01): : 57 - 59