Knee joint cartilage injuries using magnetic resonance: advantages of using 3.0 Tesla proton density-weighted sequences

被引:0
|
作者
Crespo Villalba, Francisco Jose [1 ]
机构
[1] Univ Valencia, Hosp Clin, Serv Resonancia Magnet ERESA, Valencia, Spain
来源
IMAGEN DIAGNOSTICA | 2011年 / 2卷 / 02期
关键词
Arthrosis; Knee; Cartilage; Spatial resolution; Contrast; 3.0; Tesla;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this article is to demonstrate a method for studying knee joint cartilage to be used in a 3.0 Tesla (3.0 T) MRI device. The use of proton density-weighted sequences, with and without fat suppression, and the precise setting of the image parameters to the requisites of 3.0 T, give very high resolution images with an optimum contrast between structures, so that the elements of interest can be observed with greater accuracy. A more powerful magnetic field in uences the setting of the image parameters and provides useful advantages. (C) 2011 ACTEDI. Published by Elsevier Espana, S.L. All rights reserved.
引用
收藏
页码:53 / 58
页数:6
相关论文
共 50 条
  • [21] Cardiovascular magnetic resonance imaging of aorto-iliac and ilio-femoral vascular calcifications using proton density-weighted in-phase stack of stars
    Serhal, Ali
    Koktzoglou, Ioannis
    Aouad, Pascale
    Carr, James C.
    Giri, Shivraman
    Morcos, Omar
    Edelman, Robert R.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2018, 20
  • [22] Cardiovascular magnetic resonance imaging of aorto-iliac and ilio-femoral vascular calcifications using proton density-weighted in-phase stack of stars
    Ali Serhal
    Ioannis Koktzoglou
    Pascale Aouad
    James C. Carr
    Shivraman Giri
    Omar Morcos
    Robert R. Edelman
    Journal of Cardiovascular Magnetic Resonance, 20
  • [23] USING QUANTITATIVE MEASUREMENT OF KNEE CARTILAGE VOLUME BY 3.0T MAGNETIC RESONANCE IMAGING IN DIAGNOSING OSTEOARTHRITIS
    Zhang, B.
    Zhi, X.
    Li, R.
    Lin, J.
    OSTEOARTHRITIS AND CARTILAGE, 2016, 24 : S311 - S312
  • [24] Assessment of myocardial viability using delayed enhancement magnetic resonance imaging at 3.0 tesla
    Klumpp, Bernhard
    Fenchel, Michael
    Hoevelborn, Tobias
    Helber, Uwe
    Scheule, Albertus
    Claussen, Claus
    Miller, Stephan
    INVESTIGATIVE RADIOLOGY, 2006, 41 (09) : 661 - 667
  • [25] Differential diagnosis of neurodegenerative parkinsonism using magnetic resonance imaging at 1.5 and 3.0 Tesla
    Mueller, C.
    Tashiro, J.
    Hussl, A.
    Schocke, M.
    Scherfler, C.
    Gizewski, E.
    Poewe, W.
    Seppi, K.
    EUROPEAN JOURNAL OF NEUROLOGY, 2015, 22 : 304 - 304
  • [26] Comparison of image quality in magnetic resonance imaging of the knee at 1.5 and 3.0 Tesla using 32-channel receiver coils
    Schoth, F.
    Kraemer, N.
    Niendorf, T.
    Hohl, C.
    Gunther, R. W.
    Krombach, G. A.
    EUROPEAN RADIOLOGY, 2008, 18 (10) : 2258 - 2264
  • [27] Assessment of Islet Graft Survival Using a 3.0-Tesla Magnetic Resonance Scanner
    Jiao, Yang
    Peng, Zhi-Hai
    Xing, Tong-Hai
    Qin, Jie
    Zhong, Cui-Ping
    ANATOMICAL RECORD-ADVANCES IN INTEGRATIVE ANATOMY AND EVOLUTIONARY BIOLOGY, 2008, 291 (12): : 1684 - 1692
  • [28] Comparison of image quality in magnetic resonance imaging of the knee at 1.5 and 3.0 Tesla using 32-channel receiver coils
    F. Schoth
    N. Kraemer
    T. Niendorf
    C. Hohl
    R. W. Gunther
    G. A. Krombach
    European Radiology, 2008, 18 : 2258 - 2264
  • [29] Total Knee Arthroplasty MRI Featuring Slice-Encoding for Metal Artifact Correction: Reduction of Artifacts for STIR and Proton Density-Weighted Sequences
    Sutter, Reto
    Hodek, Roman
    Fucentese, Sandro F.
    Nittka, Mathias
    Pfirrmann, Christian W. A.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 201 (06) : 1315 - 1324
  • [30] CARTILAGE DEFECTS - DETECTABILITY USING 1.5 TESLA MAGNETIC-RESONANCE-IMAGING (MRI)
    GYLYSMORIN, V
    HAJEK, PC
    SARTORIS, DJ
    RESNICK, D
    INVESTIGATIVE RADIOLOGY, 1987, 22 (09) : S33 - S33