A METHOD FOR DETERMINING SKIN DOSE IN BETA-GAMMA MIXED FIELDS USING THICK THERMOLUMINESCENT DETECTORS

被引:0
|
作者
SAHRE, P
机构
关键词
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
For determining the skin dose in beta-gamma fields of unknown composition, thin detectors or combined dosimetric systems containing thick detectors are normally used. In this paper the complete use of the depth-dose and distribution in a thick, homogeneous TL detector is proposed and investigated theoretically and experimentally. The method is based on the migration of a temperature front through the detector yielding a special glow curve. The shape of the glow curve and its location depends on the depth-dose distribution. The computer-aided unfolding of the glow curve using the superposition of standard glow curves is described. The results obtained are the skin dose in an eligible depth (less than the thickness of the detector) and the radiation components at the point of exposure. The method was tested by using several simulated mixed radiation fields. The results are presented.
引用
收藏
页码:139 / 143
页数:5
相关论文
共 50 条
  • [1] Application of Bayesian statistics for radiation dose assessment in mixed beta-gamma fields
    I. Słonecka
    J. Krasowska
    Z. Baranowska
    K. W. Fornalski
    Radiation and Environmental Biophysics, 2021, 60 : 257 - 265
  • [2] Application of Bayesian statistics for radiation dose assessment in mixed beta-gamma fields
    Slonecka, I.
    Krasowska, J.
    Baranowska, Z.
    Fornalski, K. W.
    RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2021, 60 (02) : 257 - 265
  • [3] A COMPUTERIZED METHOD FOR DISCRIMINATION OF BETA-DOSE AND GAMMA-DOSE IN A THICK THERMOLUMINESCENT DOSIMETER
    SAHRE, P
    KERNENERGIE, 1983, 26 (09): : 374 - 377
  • [4] DOSE MEASUREMENT OF MIXED BETA AND GAMMA FIELDS OF A HOMOGENEOUSLY DISTRIBUTED ISOTOPE USING POWDER AND SOLID THERMOLUMINESCENT DOSEMETERS
    SHERMAN, AA
    RUDIN, S
    MCDOUGAL.RS
    PHYSICS IN MEDICINE AND BIOLOGY, 1970, 15 (02): : 376 - &
  • [5] SURVEY INSTRUMENT FOR MIXED BETA-GAMMA RADIATION-FIELDS
    HAJNAL, F
    MCLAUGHLIN, JE
    HEALTH PHYSICS, 1977, 33 (06): : 664 - 664
  • [6] Novel beta-gamma coincidence measurements using phoswich detectors
    Ely, JH
    Aalseth, CE
    McIntyre, JI
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2005, 263 (01) : 245 - 250
  • [7] Novel beta-gamma coincidence measurements using phoswich detectors
    J. H. Ely
    C. E. Aalseth
    J. I. McIntyre
    Journal of Radioanalytical and Nuclear Chemistry, 2005, 263 : 245 - 250
  • [8] SKIN BETA-DOSE ASSESSMENT WITH ULTRA-THIN THERMOLUMINESCENT DETECTORS
    DAROSA, LAR
    CALDAS, LVE
    PHYSICS IN MEDICINE AND BIOLOGY, 1986, 31 (06): : 677 - 682
  • [9] MEASUREMENT OF SKIN DOSE FROM LOW ENERGY BETA AND GAMMA RADIATION USING THERMOLUMINESCENT DISCS
    MARSHALL, M
    DOCHERTY, J
    PHYSICS IN MEDICINE AND BIOLOGY, 1971, 16 (03): : 503 - &
  • [10] Comparison of two extremity dosemeters based on LiF:Mg,Cu,P thin detectors for mixed beta-gamma fields
    Ginjaume, M.
    Perez, S.
    Ortega, X.
    Duch, M. A.
    RADIATION PROTECTION DOSIMETRY, 2006, 120 (1-4) : 316 - 320