A METHOD FOR DETERMINING SKIN DOSE IN BETA-GAMMA MIXED FIELDS USING THICK THERMOLUMINESCENT DETECTORS

被引:0
|
作者
SAHRE, P
机构
关键词
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
For determining the skin dose in beta-gamma fields of unknown composition, thin detectors or combined dosimetric systems containing thick detectors are normally used. In this paper the complete use of the depth-dose and distribution in a thick, homogeneous TL detector is proposed and investigated theoretically and experimentally. The method is based on the migration of a temperature front through the detector yielding a special glow curve. The shape of the glow curve and its location depends on the depth-dose distribution. The computer-aided unfolding of the glow curve using the superposition of standard glow curves is described. The results obtained are the skin dose in an eligible depth (less than the thickness of the detector) and the radiation components at the point of exposure. The method was tested by using several simulated mixed radiation fields. The results are presented.
引用
收藏
页码:139 / 143
页数:5
相关论文
共 50 条
  • [21] Method for calculating radon activity and radon rejection using a beta-gamma detector
    Mayer, Michael F.
    Cooper, Matthew W.
    Ely, James H.
    Hayes, James C.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2022, 331 (12) : 5027 - 5032
  • [22] Absolute efficiency calibration of gas beta-gamma detectors using nuclear reactor irradiated radioxenon sources
    McIntyre, Justin I.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2014, 248
  • [24] ABSOLUTE MEASUREMENTS OF RADIOACTIVITY USING 4PI BETA-GAMMA COINCIDENCE METHOD
    WOOD, M
    PHYSICS IN MEDICINE AND BIOLOGY, 1970, 15 (01): : 133 - &
  • [25] MEASUREMENT OF THE DOSE AVERAGED LET IN MIXED PARTICLE FIELDS USING ALANINE DETECTORS
    Herrmann, R.
    Greilich, S.
    Jaekel, O.
    Palmans, H.
    Sharpe, P.
    Bassler, N.
    RADIOTHERAPY AND ONCOLOGY, 2012, 102 : S149 - S149
  • [26] A COMPUTER-AIDED METHOD FOR DISCRIMINATING BETWEEN BETA-DOSES AND GAMMA-DOSES IN A THICK THERMOLUMINESCENT DOSIMETER
    ROSSBANDER, W
    SAHRE, P
    ACTA PHYSICA HUNGARICA, 1986, 59 (1-2) : 177 - 180
  • [27] Dose reassessment by using PTTL method in MTS-N (LiF:Mg, Ti) thermoluminescent detectors
    Budzanowski, M.
    Sas-Bieniarz, A.
    Bilski, P.
    Bubak, A.
    Kopec, R.
    RADIATION MEASUREMENTS, 2013, 56 : 389 - 392
  • [28] METHOD OF DIRECT DETERMINATION OF THE DOSE AND THE DOSE EQUIVALENT OF THE MIXED N-GAMMA RADIATION BY MEANS OF SCINTILLATION DETECTORS
    SABOL, J
    KUBALEK, J
    JADERNA ENERGIE, 1981, 27 (02): : 51 - 55
  • [29] Single channel beta-gamma coincidence system for radioxenon measurement using well-type HPGe and plastic scintillator detectors
    Xie, Feng
    Jiang, Wengang
    Li, Xuesong
    He, Xiaobing
    Zhang, Jiamei
    Yu, Gongshuo
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 729 : 900 - 904
  • [30] Method for determination of gamma and neutron dose components in mixed radiation fields using a high-pressure recombination chamber
    Zielczynski, M.
    Gryzinski, M. A.
    Golnik, N.
    RADIATION PROTECTION DOSIMETRY, 2007, 126 (1-4) : 306 - 309