STUDIES OF FIBRINOGEN BINDING TO PLATELETS BY FLOW-CYTOMETRY - AN IMPROVED METHOD FOR STUDIES OF PLATELET ACTIVATION

被引:0
|
作者
LINDAHL, TL [1 ]
FESTIN, R [1 ]
LARSSON, A [1 ]
机构
[1] UPPSALA AKAD HOSP,DEPT CLIN IMMUNOL,S-75185 UPPSALA,SWEDEN
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Platelet function is dependent upon membrane receptors and their interaction with other proteins. Platelet activation appears to cause a structural change of the glycoprotein IIb/IIIa complex that exposes the fibrinogen binding site, which subsequently binds fibrinogen. Fluorescence-activated flow cytometry (FACS) is an efficient method for studying membrane proteins. Flow cytometry gives single-cell data, allowing the detection of only a small proportion of labelled platelets in whole blood without any washing steps. One problem with this method is that the labelled antibodies and the antigen, if present in plasma, form an immune complex, which may cause false positive reactions due to interaction between mammalian IgG and Fc-gamma receptors on thc platelets. We show that immune complexes with chicken IgG do not activate human platelets. We have developed a method for measuring platelet-bound fibrinogen in whole blood and platelet-rich plasma utilising fluorescein isothiocyanate (FITC)-conjugated chicken antibodies directed towards human fibrinogen. As low as 1% activated platelets could be detected without interference from Fc-interactions.
引用
收藏
页码:221 / 225
页数:5
相关论文
共 50 条
  • [41] DETECTION OF PLATELET ACTIVATION WITH MONOCLONAL-ANTIBODIES AND FLOW-CYTOMETRY - CHANGES DURING PLATELET STORAGE
    FIJNHEER, R
    MODDERMAN, PW
    VELDMAN, H
    OUWEHAND, WH
    NIEUWENHUIS, HK
    ROOS, D
    DEKORTE, D
    TRANSFUSION, 1990, 30 (01) : 20 - 25
  • [42] DETECTION OF PLATELET ACTIVATION WITH MONOCLONAL-ANTIBODIES AND FLOW-CYTOMETRY - CHANGES DURING PLATELET STORAGE
    FIJNHEER, R
    MODDERMAN, PW
    VELDMAN, H
    OUWEHAND, WH
    NIEUWENHUIS, HK
    ROOS, D
    DEKORTE, D
    THROMBOSIS AND HAEMOSTASIS, 1989, 62 (01) : 264 - 264
  • [43] THE CLINICAL USE OF FLOW-CYTOMETRY FOR ASSESSING PLATELET ACTIVATION IN ACUTE CORONARY SYNDROMES
    BECKER, RC
    TRACY, RP
    BOVILL, EG
    MANN, KG
    AULT, K
    CORONARY ARTERY DISEASE, 1994, 5 (04) : 339 - 345
  • [44] COMPARISON OF BETA-THROMBOGLOBULIN, FLOW-CYTOMETRY, AND THROMBOAGGREGOMETRY TO STUDY PLATELET ACTIVATION
    MATZDORFF, AC
    KEMKESMATTHES, B
    PRALLE, H
    THROMBOSIS AND HAEMOSTASIS, 1995, 73 (06) : 997 - 997
  • [45] QUANTITATION OF PLATELET ASSOCIATED IMMUNOGLOBULIN BY FLOW-CYTOMETRY
    MACEY, MG
    MORRIS, A
    HYAM, C
    NEWLAND, AC
    BRITISH JOURNAL OF HAEMATOLOGY, 1986, 64 (04) : 827 - 828
  • [46] EVALUATION OF THE PLATELET SURFACE BY FLUORESCENCE FLOW-CYTOMETRY
    SHAFI, NQ
    ANNALS OF CLINICAL AND LABORATORY SCIENCE, 1986, 16 (04): : 331 - 331
  • [47] DISAGGREGATION OF BONE-MARROW SPICULES FOR STUDIES BY FLOW-CYTOMETRY
    SOMAN, S
    KAPLOW, LS
    ACTA PATHOLOGICA ET MICROBIOLOGICA SCANDINAVICA SECTION A-PATHOLOGY, 1981, : 59 - 62
  • [48] MEASUREMENT OF LEUKOCYTE ACTIVATION WITH FLOW-CYTOMETRY
    JOHNSON, CJ
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1994, 207 : 323 - CHED
  • [49] DNA FLOW-CYTOMETRY OF HUMAN-EPIDERMIS - METHODOLOGICAL STUDIES
    FRENTZ, G
    LARSEN, JK
    CELL AND TISSUE KINETICS, 1981, 14 (06): : 667 - 667
  • [50] FLOW-CYTOMETRY AS AN ANALYTIC AND PREPARATIVE TOOL FOR STUDIES OF NEUROENDOCRINE FUNCTION
    CAMBIER, JC
    MONROE, JG
    METHODS IN ENZYMOLOGY, 1983, 103 : 227 - 245