STUDIES OF FIBRINOGEN BINDING TO PLATELETS BY FLOW-CYTOMETRY - AN IMPROVED METHOD FOR STUDIES OF PLATELET ACTIVATION

被引:0
|
作者
LINDAHL, TL [1 ]
FESTIN, R [1 ]
LARSSON, A [1 ]
机构
[1] UPPSALA AKAD HOSP,DEPT CLIN IMMUNOL,S-75185 UPPSALA,SWEDEN
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Platelet function is dependent upon membrane receptors and their interaction with other proteins. Platelet activation appears to cause a structural change of the glycoprotein IIb/IIIa complex that exposes the fibrinogen binding site, which subsequently binds fibrinogen. Fluorescence-activated flow cytometry (FACS) is an efficient method for studying membrane proteins. Flow cytometry gives single-cell data, allowing the detection of only a small proportion of labelled platelets in whole blood without any washing steps. One problem with this method is that the labelled antibodies and the antigen, if present in plasma, form an immune complex, which may cause false positive reactions due to interaction between mammalian IgG and Fc-gamma receptors on thc platelets. We show that immune complexes with chicken IgG do not activate human platelets. We have developed a method for measuring platelet-bound fibrinogen in whole blood and platelet-rich plasma utilising fluorescein isothiocyanate (FITC)-conjugated chicken antibodies directed towards human fibrinogen. As low as 1% activated platelets could be detected without interference from Fc-interactions.
引用
收藏
页码:221 / 225
页数:5
相关论文
共 50 条
  • [31] DETECTION OF PLATELET AUTOANTIBODIES BY FLOW-CYTOMETRY
    MACEY, MG
    MORRIS, A
    HYAM, C
    SANGSTER, J
    NEWLAND, AC
    INSTITUTE OF PHYSICS CONFERENCE SERIES, 1990, (98): : 841 - 844
  • [32] THE DETECTION OF PLATELET ALLOANTIBODIES BY FLOW-CYTOMETRY
    WORFOLK, LA
    MACPHERSON, BR
    TRANSFUSION, 1991, 31 (04) : 340 - 344
  • [33] FLOW-CYTOMETRY OF THE COMPATIBILITY OF PLATELET TRANSFUSIONS
    DITTMANN, J
    LYNEN, R
    HUMPE, A
    RIGGERT, J
    LEGLER, T
    NEUMEYER, H
    KOHLER, M
    INFUSIONSTHERAPIE UND TRANSFUSIONSMEDIZIN, 1995, 22 : 54 - 55
  • [34] HETEROGENEITY OF FIBRINOGEN RECEPTOR EXPRESSION ON PLATELETS ACTIVATED IN NORMAL PLASMA WITH ADP - ANALYSIS BY FLOW-CYTOMETRY
    JACKSON, CW
    JENNINGS, LK
    BRITISH JOURNAL OF HAEMATOLOGY, 1989, 72 (03) : 407 - 414
  • [35] THE USE OF FLOW-CYTOMETRY FOR STUDIES OF CELLULAR-DIFFERENTIATION
    SWARTZENDRUBER, DE
    MARTIN, JC
    IN VITRO-JOURNAL OF THE TISSUE CULTURE ASSOCIATION, 1983, 19 (03): : 245 - 246
  • [36] APPLICATION OF FLOW-CYTOMETRY IN STUDIES OF NUCLEAR CHROMATIN STRUCTURE
    DARZYNKIEWICZ, Z
    CYTOMETRY, 1981, 2 (02): : 95 - 95
  • [37] Blood platelet activation evaluated by flow cytometry: optimised methods for clinical studies
    Hagberg, IA
    Lyberg, T
    PLATELETS, 2000, 11 (03) : 137 - 150
  • [38] QUANTIFICATION OF PLATELET GLYCOPROTEINS AND PLATELET ANTIGENS BY FLOW-CYTOMETRY
    BOIZARD, B
    GRUEL, Y
    MIGLIERINA, R
    WAUTIER, JI
    BIOLOGY OF THE CELL, 1984, 52 (03) : A129 - A129
  • [39] THE EFFECT OF THE FIBRINOGEN RECEPTOR ANTAGONIST, GR144053, UPON FIBRINOGEN BINDING AND P-SELECTIN EXPRESSION IN HUMAN PLATELETS - ANALYSIS USING FLOW-CYTOMETRY
    GOODALL, AH
    WILSON, DJ
    LUMLEY, P
    THROMBOSIS AND HAEMOSTASIS, 1993, 69 (06) : 1071 - 1071
  • [40] CHARACTERIZATION OF CANINE PLATELET P-SELECTIN (CD-62) AND ITS UTILITY IN FLOW-CYTOMETRY PLATELET STUDIES
    YEO, EL
    GEMMELL, CH
    SUTHERLAND, DR
    SEFTON, MV
    COMPARATIVE BIOCHEMISTRY AND PHYSIOLOGY B-BIOCHEMISTRY & MOLECULAR BIOLOGY, 1993, 105 (3-4): : 625 - 636