EXPERIMENTAL ANALYSIS OF MICROCHANNEL CONDENSER USING R134a AND DROP IN SUBSTITUTE HYDROCARBON MIXTURE OF R290 AND R600a

被引:0
|
作者
Bhatkar, V. W. [1 ]
Kriplani, V. M. [2 ]
Awari, G. K. [3 ]
机构
[1] RTM Nagpur Univ, GH Raisoni Coll Engn, Dept Mech Engn, Nagpur, Maharashtra, India
[2] GH Raisoni Coll Engn, Fac Mech Engn, Nagpur 440016, Maharashtra, India
[3] Tulsiramji Gaikwad Patil Coll Engn & Technol, Nagpur, Maharashtra, India
关键词
Coefficient of performance; hydrocarbon mixture; refrigerant; condenser capacity; compressor power consumption;
D O I
10.15282/ijame.10.2014.16.0167
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Microchannel condensers are widely used in automobile and household air conditioners with R134a as a refrigerant. In order to reduce the global warming potential as well as the refrigerant charge, hydrocarbon mixture of R290 and R600a (50:50 % by mass) was used as a drop in substitute to R134a in the vapour compression refrigeration system. Versatile vapour compression refrigeration system of 1 ton of refrigeration capacity was designed, developed and fabricated for testing different refrigerants. Various parameters such as ambient temperature in the condenser cabin, different condensation and evaporation temperatures, different mass flow rates of refrigerant and air can be controlled precisely in the test rig. Experiments were performed using R134a and hydrocarbon mixture of R290 and R600a (50:50 % by mass) for condensation temperature of 44 degrees C and evaporation temperature ranging from -15 to 15 degrees C. Refrigerant charge was reduced by 45 % with the hydrocarbon mixture of R290 and R600a (50: 50 % by mass) over R134a. Performance parameters such as compressor power consumption increases by 13.3 %, coefficient of performance reduced by 43 %, refrigeration capacity increased by 140.8 %, condenser capacity increased by 185.4 % and the product of overall heat transfer coefficient and surface area of condenser was increased by 243.7 % by using hydrocarbon mixture of R290 and R600a (50:50 % by mass) over R134a with the microchannel condenser at condensation temperature of 44 degrees C and evaporation temperature of 0 degrees C. It is suggested to use an environmental friendly refrigerant, hydrocarbon mixture of R290 and R600a (50: 50 % by mass) as a drop in substitute to the conventional refrigerant R134a in the automobile, household air conditioning and refrigeration systems.
引用
收藏
页码:1993 / 2002
页数:10
相关论文
共 50 条
  • [31] Experimental study of R290 replacement R134a in cold storage air conditioning system
    Zheng, Huifan
    Tian, Guoji
    Zhao, Yahui
    Jin, Chao
    Ju, Fujun
    Wang, Congmin
    CASE STUDIES IN THERMAL ENGINEERING, 2022, 36
  • [32] SECOND LAW ANALYSIS OF AN ENVIRONMENTALLY FRIENDLY R290/R600/R600a MIXTURE IN A WATER-COOLED HEAT PUMP UNIT
    Menlik, Tayfun
    Ozcan, Hasan
    Arcaklioglu, Erol
    ISI BILIMI VE TEKNIGI DERGISI-JOURNAL OF THERMAL SCIENCE AND TECHNOLOGY, 2014, 34 (02) : 19 - 28
  • [33] Energy comparison based on experimental results of a cascade refrigeration system pairing R744 with R134a, R1234ze(E) and the natural refrigerants R290, R1270, R600a
    Cabello, R.
    Andreu-Nacher, A.
    Sandhez, D.
    Llopis, R.
    Vidan-Falomir, F.
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 148 : 131 - 142
  • [34] EXPERIMENTAL INVESTIGATION OF R600a/TIO2 AS A DROP-IN REPLACEMENT FOR R134a IN A HOUSEHOLD REFRIGERATION SYSTEM
    Babarinde, T. O.
    Akinlabi, S. A.
    Madyira, D. M.
    4TH THERMAL AND FLUIDS ENGINEERING CONFERENCE, ASTFE 2019, 2019,
  • [35] Exergy analysis and optimization of R600a as a replacement of R134a in a domestic refrigerator system
    Joybari, Mahmood Mastani
    Hatamipour, Mohammad Sadegh
    Rahimi, Amir
    Modarres, Fatemeh Ghadiri
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2013, 36 (04): : 1233 - 1242
  • [36] PVTx properties in the gas phase for binary R290/R134a system
    Qi, Yingxia
    Zhang, Hua
    Liu, Yefeng
    Wu, Weidong
    Chen, Xi
    Yang, Xi
    JOURNAL OF CHEMICAL THERMODYNAMICS, 2014, 70 : 111 - 121
  • [37] Thermodynamics studies on VCRS using refrigerant blends of R290, R600A, and R1234ZE
    Ravi, Govarthanan
    Adhimoulame, Kalaisselvane
    MULTISCALE AND MULTIDISCIPLINARY MODELING EXPERIMENTS AND DESIGN, 2024, 7 (05) : 4807 - 4818
  • [38] Lubricity evaluation of oil-refrigerant mixtures with R134a and R290
    Gorny, Kasper
    Stachowiak, Arkadiusz
    Tyczewski, Przemystaw
    Zwierzycki, Wieslaw
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2016, 69 : 261 - 271
  • [39] Performance evaluation of a fin-and-tube evaporator with R407C/R290/R600a refrigerant mixture
    Raj, M. H.
    Lal, D. M.
    INTERNATIONAL JOURNAL OF AMBIENT ENERGY, 2010, 31 (01) : 33 - 46
  • [40] Performance evaluation on an internal auto-cascade refrigeration cycle with mixture refrigerant R290/R600a
    Yan, Gang
    Hu, Hui
    Yu, Jianlin
    APPLIED THERMAL ENGINEERING, 2015, 75 : 994 - 1000