EXPERIMENTAL ANALYSIS OF MICROCHANNEL CONDENSER USING R134a AND DROP IN SUBSTITUTE HYDROCARBON MIXTURE OF R290 AND R600a

被引:0
|
作者
Bhatkar, V. W. [1 ]
Kriplani, V. M. [2 ]
Awari, G. K. [3 ]
机构
[1] RTM Nagpur Univ, GH Raisoni Coll Engn, Dept Mech Engn, Nagpur, Maharashtra, India
[2] GH Raisoni Coll Engn, Fac Mech Engn, Nagpur 440016, Maharashtra, India
[3] Tulsiramji Gaikwad Patil Coll Engn & Technol, Nagpur, Maharashtra, India
关键词
Coefficient of performance; hydrocarbon mixture; refrigerant; condenser capacity; compressor power consumption;
D O I
10.15282/ijame.10.2014.16.0167
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Microchannel condensers are widely used in automobile and household air conditioners with R134a as a refrigerant. In order to reduce the global warming potential as well as the refrigerant charge, hydrocarbon mixture of R290 and R600a (50:50 % by mass) was used as a drop in substitute to R134a in the vapour compression refrigeration system. Versatile vapour compression refrigeration system of 1 ton of refrigeration capacity was designed, developed and fabricated for testing different refrigerants. Various parameters such as ambient temperature in the condenser cabin, different condensation and evaporation temperatures, different mass flow rates of refrigerant and air can be controlled precisely in the test rig. Experiments were performed using R134a and hydrocarbon mixture of R290 and R600a (50:50 % by mass) for condensation temperature of 44 degrees C and evaporation temperature ranging from -15 to 15 degrees C. Refrigerant charge was reduced by 45 % with the hydrocarbon mixture of R290 and R600a (50: 50 % by mass) over R134a. Performance parameters such as compressor power consumption increases by 13.3 %, coefficient of performance reduced by 43 %, refrigeration capacity increased by 140.8 %, condenser capacity increased by 185.4 % and the product of overall heat transfer coefficient and surface area of condenser was increased by 243.7 % by using hydrocarbon mixture of R290 and R600a (50:50 % by mass) over R134a with the microchannel condenser at condensation temperature of 44 degrees C and evaporation temperature of 0 degrees C. It is suggested to use an environmental friendly refrigerant, hydrocarbon mixture of R290 and R600a (50: 50 % by mass) as a drop in substitute to the conventional refrigerant R134a in the automobile, household air conditioning and refrigeration systems.
引用
收藏
页码:1993 / 2002
页数:10
相关论文
共 50 条
  • [21] Performance evaluation of a vapor injection refrigeration system using mixture refrigerant R290/R600a
    Hallak d'Angelo, Jose Vicente
    Aute, Vikrant
    Radermacher, Reinhard
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2016, 65 : 194 - 208
  • [22] Development of Statistical Models for Predicting Performance of R12, R134a and R290/R600 Mixture Refrigerants using Design of Experiments
    Mani, K.
    Selladurai, V.
    Murugan, N.
    INTERNATIONAL JOURNAL OF THERMODYNAMICS, 2013, 16 (01) : 43 - 53
  • [23] An approximate model of a multilayer wire-on-tube condenser operating with R134a and R600a: Experimental validation and parametric analysis
    Belman-Flores, J. M.
    Heredia-Aricapa, Y.
    Garcia-Pabon, Juan J.
    Gallegos-Munoz, A.
    Serrano-Arellano, J.
    Perez-Reguera, C. Gutierrez
    CASE STUDIES IN THERMAL ENGINEERING, 2021, 25
  • [24] Experimental comparison of R290 and R600a and prediction of performance with machine learning algorithms
    Pektezel, Oguzhan
    Acar, Halil Ibrahim
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2023, 29 (05) : 508 - 522
  • [25] Experimental study of R290/R600a mixtures in vapor compression refrigeration system
    Ozsipahi, Mustafa
    Kose, Haluk Anil
    Kerpicci, Husnu
    Gunes, Hasan
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2022, 133 : 247 - 258
  • [26] COMPARATIVE EXERGY ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING R134A AND R290
    Soni, Shubham
    Ali, Mohammad
    Chandra, P. Sharat
    Khare, Ashutosh
    Jain, Abhi
    ADVANCES AND APPLICATIONS IN MATHEMATICAL SCIENCES, 2020, 20 (01): : 113 - 121
  • [27] Thermodynamic analysis on a modified ejector expansion refrigeration cycle with zeotropic mixture (R290/R600a) for freezers
    Yan, Gang
    Bai, Tao
    Yu, Jianlin
    ENERGY, 2016, 95 : 144 - 154
  • [28] 中高温热泵混合工质R13I1/R290/R600a替代R134a的理论研究
    向璨
    常华伟
    段晨
    文科
    舒水明
    太阳能学报, 2018, 39 (10) : 2760 - 2766
  • [29] Energy performance evaluation of R1234yf, R1234ze(E), R600a, R290 and R152a as low-GWP R134a alternatives
    Sanchez, D.
    Cabello, R.
    Llopis, R.
    Arauzo, I.
    Catalan-Gil, J.
    Torrella, E.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2017, 74 : 269 - 282
  • [30] Experimental investigation of R600a as a drop-in replacement for R134a in a VCRS-based magnetized water chiller
    Deshmukh, Rahul G.
    Zanwar, Dinesh R.
    Joshi, Sandeep S.
    Joshi, Yogesh G.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART E-JOURNAL OF PROCESS MECHANICAL ENGINEERING, 2025,