EXPERIMENTAL ANALYSIS OF MICROCHANNEL CONDENSER USING R134a AND DROP IN SUBSTITUTE HYDROCARBON MIXTURE OF R290 AND R600a

被引:0
|
作者
Bhatkar, V. W. [1 ]
Kriplani, V. M. [2 ]
Awari, G. K. [3 ]
机构
[1] RTM Nagpur Univ, GH Raisoni Coll Engn, Dept Mech Engn, Nagpur, Maharashtra, India
[2] GH Raisoni Coll Engn, Fac Mech Engn, Nagpur 440016, Maharashtra, India
[3] Tulsiramji Gaikwad Patil Coll Engn & Technol, Nagpur, Maharashtra, India
关键词
Coefficient of performance; hydrocarbon mixture; refrigerant; condenser capacity; compressor power consumption;
D O I
10.15282/ijame.10.2014.16.0167
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Microchannel condensers are widely used in automobile and household air conditioners with R134a as a refrigerant. In order to reduce the global warming potential as well as the refrigerant charge, hydrocarbon mixture of R290 and R600a (50:50 % by mass) was used as a drop in substitute to R134a in the vapour compression refrigeration system. Versatile vapour compression refrigeration system of 1 ton of refrigeration capacity was designed, developed and fabricated for testing different refrigerants. Various parameters such as ambient temperature in the condenser cabin, different condensation and evaporation temperatures, different mass flow rates of refrigerant and air can be controlled precisely in the test rig. Experiments were performed using R134a and hydrocarbon mixture of R290 and R600a (50:50 % by mass) for condensation temperature of 44 degrees C and evaporation temperature ranging from -15 to 15 degrees C. Refrigerant charge was reduced by 45 % with the hydrocarbon mixture of R290 and R600a (50: 50 % by mass) over R134a. Performance parameters such as compressor power consumption increases by 13.3 %, coefficient of performance reduced by 43 %, refrigeration capacity increased by 140.8 %, condenser capacity increased by 185.4 % and the product of overall heat transfer coefficient and surface area of condenser was increased by 243.7 % by using hydrocarbon mixture of R290 and R600a (50:50 % by mass) over R134a with the microchannel condenser at condensation temperature of 44 degrees C and evaporation temperature of 0 degrees C. It is suggested to use an environmental friendly refrigerant, hydrocarbon mixture of R290 and R600a (50: 50 % by mass) as a drop in substitute to the conventional refrigerant R134a in the automobile, household air conditioning and refrigeration systems.
引用
收藏
页码:1993 / 2002
页数:10
相关论文
共 50 条
  • [1] Research on flammability of R290/R134a, R600a/R134a and R600a/R290 refrigerant mixtures
    Cai, Dehua
    Hao, Zian
    Xu, Hao
    He, Guogeng
    International Journal of Refrigeration, 2022, 137 : 53 - 61
  • [2] Research on flammability of R290/R134a, R600a/R134a and R600a/R290 refrigerant mixtures
    Cai, Dehua
    Hao, Zian
    Xu, Hao
    He, Guogeng
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2022, 137 : 53 - 61
  • [3] Experimental investigation of R290/R600a mixture as an alternative to R134a in a domestic refrigerator
    Mohanraj, M.
    Jayaraj, S.
    Muraleedharan, C.
    Chandrasekar, P.
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2009, 48 (05) : 1036 - 1042
  • [4] Study of refrigeration system with minichannel condenser using R1234ze, R134a, R152a, R600a, R290 and mixture of R290/R600a (50/50)
    Bhatkar, Vijay
    Sur, Anirban
    Kumar, Ramesh
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART E-JOURNAL OF PROCESS MECHANICAL ENGINEERING, 2023,
  • [5] Experimental Study on the Thermal Performance of R600a, R290 and R600a/R290 Mixtures in a Retrofit R134a Refrigeration System
    Ramathe, Teboho
    Huan, Zhongjie
    Mwesigye, Aggrey
    PROCEEDINGS OF THE 13TH CONFERENCE ON THE INDUSTRIAL AND COMMERCIAL USE OF ENERGY, 2015, : 178 - 186
  • [6] Measurements of the surface tension for R290, R600a and R290/R600a mixture
    Tanaka, Katsuyuki
    Higashi, Yukihiro
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2007, 30 (08): : 1368 - 1373
  • [7] Experimental study on hydrocarbon mixture refrigerant R600a/R290 in refrigerator
    Du, YP
    Lu, J
    Chen, H
    Sun, Y
    Yin, CX
    PROCEEDINGS OF THE 3RD INTERNATIONAL SYMPOSIUM ON HEAT TRANSFER ENHANCEMENT AND ENERGY CONSERVATION, VOLS 1 AND 2, 2004, : 1054 - 1057
  • [8] EXPERIMENTAL INVESTIGATIONS ON AUTOMOBILE AIR CONDITIONERS WORKING WITH R134a AND R290/R600a AS AN ALTERNATIVE
    Kandhaswamy, Karthikeyan
    Periasamy, Somasundaram
    Mayilsamy, Sivakumar
    Thangavel, Saravanakumar
    THERMAL SCIENCE, 2017, 21 : S515 - S522
  • [9] Exergy analysis of a domestic refrigerator using eco-friendly R290/R600a refrigerant mixture as an alternative to R134a
    Saravanakumar, R.
    Selladurai, V.
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2014, 115 (01) : 933 - 940
  • [10] Exergy analysis of a domestic refrigerator using eco-friendly R290/R600a refrigerant mixture as an alternative to R134a
    R. Saravanakumar
    V. Selladurai
    Journal of Thermal Analysis and Calorimetry, 2014, 115 : 933 - 940