TIME-RESOLVED FLUOROMETRY - PRINCIPLES AND APPLICATIONS IN CLINICAL-CHEMISTRY

被引:0
|
作者
GAILLARD, O
KAPEL, N
GALLI, J
DELATTRE, J
MEILLET, D
机构
[1] HOP LA PITIE SALPETRIERE, INSERM, U134, NEUROIMMUNOL LAB, PARIS 13, FRANCE
[2] HOP LA PITIE SALPETRIERE, BIOCHIM LAB, PARIS 13, FRANCE
[3] HOP BICHAT CLAUDE BERNARD, PARASITOL ORIENTAT COPROL LAB, F-75005 PARIS, FRANCE
[4] FAC MED & PHARM BESANCON, PARASITOL & MYCOL LAB, F-25030 BESANCON, FRANCE
关键词
TIME-RESOLVED IMMUNOFLUOROMETRIC ASSAY; EUROPIUM;
D O I
暂无
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Time-resolved fluorometric assay is based on lanthanide fluorescence. This time-resolved fluorescence has a narrow-band emission line whose wavelength differs from that of emission-pulsed light and has a long decay-time. These characteristics make it possible to avoid background interference from sample constituents (protein, light-scattering particles, etc). Europium and its chelates are the most commonly used lanthanides. The europium-labeling of antigens or antibodies is followed by immunoassay. In the final step, fluorescence is measured, after enhancement, as counts per second. This assay has several advantages, including a wide working range, high sensitivity and good practicability. The method has widespread applications in the field of immunoassays in both clinical and research laboratories. The use of non-radioactive europium-labelled probes and the development of simultaneous multiple tests are possible future orientations.
引用
收藏
页码:751 / 755
页数:5
相关论文
共 50 条
  • [21] HLA typing assays based on time-resolved fluorometry detection
    Sjöroos, M
    Ilonen, J
    Seppälä, J
    Blomberg, K
    [J]. TISSUE ANTIGENS, 2002, 59 : 77 - 78
  • [22] TIME-RESOLVED FLUOROMETRY AS A SENSITIVE METHOD IN THE QUANTIFICATION OF HYBRIDIZED DNA
    SODERLUND, H
    SYVANEN, AC
    LAAKSONEN, M
    RANKI, M
    [J]. DNA-A JOURNAL OF MOLECULAR & CELLULAR BIOLOGY, 1986, 5 (01): : 90 - 90
  • [23] Sensitive bioaffinity assays with individual microparticles and time-resolved fluorometry
    Lovgren, T
    Heinonen, P
    Lehtinen, P
    Hakala, H
    Heinola, J
    Harju, R
    Takalo, H
    Mukkala, VM
    Schmid, R
    Lonnberg, H
    Pettersson, K
    Iitia, A
    [J]. CLINICAL CHEMISTRY, 1997, 43 (10) : 1937 - 1943
  • [24] SENSITIVE DETECTION OF GENES BY SANDWICH HYBRIDIZATION AND TIME-RESOLVED FLUOROMETRY
    DAHLEN, P
    SYVANEN, AC
    HURSKAINEN, P
    KWIATKOWSKI, M
    SUND, C
    YLIKOSKI, J
    SODERLUND, H
    LOVGREN, T
    [J]. MOLECULAR AND CELLULAR PROBES, 1987, 1 (02) : 159 - 168
  • [25] Application of time-resolved fluorometry to immunoassays for bovine reproductive hormones
    Kaneko, Hiroyuki
    Hasegawa, Yoshihisa
    [J]. ANIMAL SCIENCE JOURNAL, 2007, 78 (01) : 7 - 15
  • [26] ULTRA-SENSITIVE MONITORING OF ENZYMES BY TIME-RESOLVED FLUOROMETRY
    LYTLE, FE
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1990, 199 : 61 - ENVR
  • [27] PRINCIPLES OF INSTRUMENT AND EQUIPMENT EVALUATION IN CLINICAL-CHEMISTRY
    HAECKEL, R
    [J]. PTB-MITTEILUNGEN, 1980, 90 (03): : 187 - 192
  • [28] MICROCOMPUTER APPLICATIONS TO PROBLEMS IN CLINICAL-CHEMISTRY
    BOWIE, LJ
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1985, 190 (SEP): : 19 - ANL
  • [29] ENZYME THERMISTOR APPLICATIONS IN CLINICAL-CHEMISTRY
    DANIELSSON, B
    MATTIASSON, B
    MOSBACH, K
    [J]. SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1977, 37 : 89 - 89