NORMAL LEFT-VENTRICULAR DIMENSIONS AND FUNCTION - INTERSTUDY REPRODUCIBILITY OF MEASUREMENTS WITH CINE MR IMAGING

被引:345
|
作者
SEMELKA, RC [1 ]
TOMEI, E [1 ]
WAGNER, S [1 ]
MAYO, J [1 ]
KONDO, C [1 ]
SUZUKI, J [1 ]
CAPUTO, GR [1 ]
HIGGINS, CB [1 ]
机构
[1] UNIV CALIF SAN FRANCISCO,DEPT RADIOL,BOX 0628,C309,SAN FRANCISCO,CA 94143
关键词
Heart; ejection fraction; flow dynamics; function; MR studies; 524.1214; ventricles; volume; Magnetic resonance (MR); cine study;
D O I
10.1148/radiology.174.3.2305059
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The authors evaluated the reproducibility of measurements of ventricular dimensions obtained with cine magnetic resonance (MR) imaging performed on two occasions in 11 healthy subjects. Two reviewers analyzed the studies in a blinded fashion to determine interobserver and interstudy variability of measurements of left ventricular (LV) mass, volume, ejection fraction, and systolic wall stress. LV mass showed good reproducibility between studies, with 3.6% and 3.8% variability for LV end-systolic mass for the two observers. LV end-diastolic volume varied by 5.2% and 3.9%, and LV end-systolic volume, by 9.7% and 9.0%. Variability for LV ejection fraction was 5.0% and 4.9%. The largest interstudy variability was end-systolic wall stress, 11.1% and 13.5%, which was due mostly to changes in arterial pressure between the two studies. It is concluded that anatomic and functional measurements from cine MR images are reproducible between studies. The small interstudy variability is likely related to the fact that the measurements are derived directly from cine MR images that encompass the entire heart rather than depend on measurements of only sample images and the use of geometric models.
引用
收藏
页码:763 / 768
页数:6
相关论文
共 50 条
  • [21] REPRODUCIBILITY IN ECHOCARDIOGRAPHIC ASSESSMENT OF LEFT-VENTRICULAR DIMENSIONS IN ACUTE MI
    PRAKASH, R
    CARDIOVASCULAR MEDICINE, 1978, 3 (09): : 985 - 985
  • [22] LEFT-VENTRICULAR VOLUMES MEASURED BY MR IMAGING
    REHR, RB
    MALLOY, CR
    FILIPCHUK, NG
    PESHOCK, RM
    RADIOLOGY, 1985, 156 (03) : 717 - 719
  • [23] Normal nonuniformity of left ventricular contraction - Assessment by cine MR imaging with presaturation myocardial tagging
    Naito, H
    Arisawa, J
    Harada, K
    Yamagami, H
    Kozuka, T
    Tamura, S
    ACTA RADIOLOGICA, 1996, 37 (05) : 767 - 774
  • [24] DETERMINATION OF LEFT-VENTRICULAR VOLUME AND MASS WITH USE OF BIPHASIC SPIN-ECHO MR IMAGING - COMPARISON WITH CINE MR
    CAPUTO, GR
    SUZUKI, JI
    KONDO, C
    CHO, H
    QUAIFE, RA
    HIGGINS, CB
    PARKER, DL
    RADIOLOGY, 1990, 177 (03) : 773 - 777
  • [25] BEAT-TO-BEAT VARIATION IN ECHOCARDIOGRAPHIC MEASUREMENTS OF LEFT-VENTRICULAR DIMENSIONS AND FUNCTION
    BETT, JHN
    DRYBURGH, LG
    JOURNAL OF CLINICAL ULTRASOUND, 1981, 9 (03) : 119 - 125
  • [26] Effect of endocardial trabeculae on left ventricular measurements and measurement reproducibility at cardiovascular MR imaging
    Papavassiliu, T
    Kühl, HP
    Schröder, M
    Süselbeck, T
    Bondarenko, O
    Böhm, CK
    Beek, A
    Hofman, MMB
    van Rossum, AC
    RADIOLOGY, 2005, 236 (01) : 57 - 64
  • [27] QUANTITATIVE ASSESSMENT OF RESPONSE OF LEFT-VENTRICULAR PARAMETERS TO ANTIHYPERTENSIVE THERAPY BY USING CINE MR-IMAGING
    ALBRECHT, T
    DULCE, MC
    DULCE, KK
    WOLF, K
    RADIOLOGY, 1995, 197 : 256 - 256
  • [28] DIGITIZED ECHOCARDIOGRAPHIC MEASUREMENTS OF LEFT-VENTRICULAR FUNCTION - REPRODUCIBILITY AND PHYSIOLOGICAL FACTORS INFLUENCING THE METHOD
    DANIELSEN, R
    NORDREHAUG, JE
    VIKMO, H
    CLINICAL PHYSIOLOGY, 1987, 7 (05): : 411 - 421
  • [29] REPRODUCIBILITY OF SERIAL M-MODE AND DOPPLER ECHOCARDIOGRAPHIC RECORDINGS OF LEFT-VENTRICULAR DIMENSIONS AND FUNCTION
    OTTERSTAD, JE
    HURLEN, M
    MICHELSEN, S
    KNUTSEN, KM
    ANNALS OF CLINICAL RESEARCH, 1987, 19 (06): : 434 - 434
  • [30] LEFT-VENTRICULAR THROMBUS WITH NORMAL LEFT-VENTRICULAR FUNCTION IN ULCERATIVE-COLITIS
    CHIN, WW
    VANTOSH, A
    HECHT, SR
    BERGER, M
    AMERICAN HEART JOURNAL, 1988, 116 (02) : 562 - 563