Effect of endocardial trabeculae on left ventricular measurements and measurement reproducibility at cardiovascular MR imaging

被引:162
|
作者
Papavassiliu, T
Kühl, HP
Schröder, M
Süselbeck, T
Bondarenko, O
Böhm, CK
Beek, A
Hofman, MMB
van Rossum, AC
机构
[1] Univ Hosp Mannheim, Med Clin 1, D-68167 Mannheim, Germany
[2] Univ Hosp Mannheim, Dept Radiol, D-68167 Mannheim, Germany
[3] Vrije Univ Amsterdam, Ctr Med, Dept Cardiol, Amsterdam, Netherlands
关键词
D O I
10.1148/radiol.2353040601
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To prospectively assess the effect of including or excluding endocardial trabeculae in left ventricular (LV) measurements and the reproducibility of these measurements at cine cardiovascular magnetic resonance (MR) imaging with true fast imaging with steady-state precession (FISP). MATERIALS AND METHODS: The study was approved by the local ethics committee, and each subject gave informed consent before participating. Twenty healthy subjects and 20 consecutive patients underwent 1.5-T cardiovascular MR imaging. Seven to 12 short-axis views encompassing the entire LV were acquired by using true FISP. Endocardial and epicardial contours were traced manually. The data sets in each patient were analyzed twice: with inclusion of endocardial trabeculae in the LV cavity volume and with exclusion of endocardial trabeculae from the cavity volume. On the basis of these two contour sets, the end-diastolic (ED) and endsystolic (ES) LV volumes, ejection fraction (EF), and LV mass were calculated. Additionally, interobserver and interexamination reproducibility was assessed by using Bland-Altman analysis. RESULTS: Compared with exclusion of trabeculae, inclusion of trabeculae in the LV cavity volume resulted in significantly larger ED and ES LV volumes (mean differences, 21 mL +/- 11 [standard deviation] and 19 mL +/- 33, respectively; P <.001) and lower EFs (mean difference, -2% +/- 2; P <.001). The calculated LV mass was significantly smaller with inclusion than with exclusion of trabeculae (mean difference, -21 g +/- 12; P <.001), All interobserver and interexamination limits of agreement based on inclusion of trabeculae, except those for EF measurements, were superior to those based on exclusion of trabeculae. At measurement reproducibility comparisons, differences in interobserver ED LV volume and LV mass and interexamination LV mass were statistically significant, favoring the inclusion of trabeculae in the LV cavity volume. CONCLUSION: Trabeculae significantly affect quantifications of LV volume and mass. The superior reproducibility of LV measurements with the inclusion of endocardial trabeculae in the cavity volume favors this tracing algorithm for clinical use. ((c)) RSNA, 2005.
引用
收藏
页码:57 / 64
页数:8
相关论文
共 50 条
  • [1] Operator induced variability in cardiovascular MR: left ventricular measurements and their reproducibility
    Danilouchkine, MG
    Westenberg, JJM
    de Roos, A
    Reiber, JHC
    Lelieveldt, BPF
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2005, 7 (02) : 447 - 457
  • [2] Left ventricular mass measured by magnetic resonance imaging: effect of endocardial trabeculae on the observed wall thickness
    Marcus, JT
    Kuijer, JPA
    Goette, MJW
    Van Rossum, AC
    Heethaar, RM
    EUROPEAN HEART JOURNAL, 2000, 21 : 572 - 572
  • [3] Effect of Papillary Muscles and Trabeculae on Left Ventricular Measurement Using Cardiovascular Magnetic Resonance Imaging in Patients with Hypertrophic Cardiomyopathy
    Park, Eun-Ah
    Lee, Whal
    Kim, Hyung-Kwan
    Chung, Jin Wook
    KOREAN JOURNAL OF RADIOLOGY, 2015, 16 (01) : 4 - 12
  • [4] NORMAL LEFT-VENTRICULAR DIMENSIONS AND FUNCTION - INTERSTUDY REPRODUCIBILITY OF MEASUREMENTS WITH CINE MR IMAGING
    SEMELKA, RC
    TOMEI, E
    WAGNER, S
    MAYO, J
    KONDO, C
    SUZUKI, J
    CAPUTO, GR
    HIGGINS, CB
    RADIOLOGY, 1990, 174 (03) : 763 - 768
  • [5] Breath-hold FLASH and FISP cardiovascular MR imaging: Left ventricular volume differences and reproducibility
    Moon, JCC
    Lorenz, CH
    Francis, JM
    Smith, GC
    Pennell, DJ
    RADIOLOGY, 2002, 223 (03) : 789 - 797
  • [6] Cardiovascular magnetic resonance: interstudy reproducibility of measurements of left ventricular function in children
    Jennifer A Bryant
    Keith M Godfrey
    Mark A Hanson
    Sheila Barton
    Charles R Peebles
    Journal of Cardiovascular Magnetic Resonance, 13 (Suppl 1)
  • [7] Left ventricular spherical remodeling and apical myocardial relaxation: Cardiovascular MR imaging measurement of myocardial segments
    Tumkosit, Monravee
    Martin, Carla G.
    Bayram, Ersin
    Morgan, Timothy M.
    Lane, Kimberly S.
    Rerkpattanapipat, Pairoj
    Hamilton, Craig A.
    Link, Kerry M.
    Hundley, W. Gregory
    RADIOLOGY, 2007, 244 (02) : 411 - 418
  • [8] LEFT-VENTRICULAR MEASUREMENTS WITH CINE AND SPIN-ECHO MR IMAGING - A STUDY OF REPRODUCIBILITY WITH VARIANCE COMPONENT ANALYSIS
    PATTYNAMA, PMT
    LAMB, HJ
    VANDERVELDE, EA
    VANDERWALL, EE
    DEROOS, A
    RADIOLOGY, 1993, 187 (01) : 261 - 268
  • [9] Effect of Dual-Source Radiofrequency Transmission on Left Ventricular Measurements and Measurement Reproducibility at 3.0 T Cardiac MR Imaging: Comparison with Conventional Single-Source Transmission Reference
    Li, Chunhai
    Liu, Bo
    Meng, Hong
    Wang, Guangbin
    Wang, Cuiyan
    Jia, Haipeng
    ACADEMIC RADIOLOGY, 2019, 26 (05) : E56 - E66
  • [10] REPRODUCIBILITY OF ECHOCARDIOGRAPHIC LEFT-VENTRICULAR MEASUREMENTS
    WALLERSON, DC
    DEVEREUX, RB
    HYPERTENSION, 1987, 9 (02) : 6 - 18