Effect of endocardial trabeculae on left ventricular measurements and measurement reproducibility at cardiovascular MR imaging

被引:162
|
作者
Papavassiliu, T
Kühl, HP
Schröder, M
Süselbeck, T
Bondarenko, O
Böhm, CK
Beek, A
Hofman, MMB
van Rossum, AC
机构
[1] Univ Hosp Mannheim, Med Clin 1, D-68167 Mannheim, Germany
[2] Univ Hosp Mannheim, Dept Radiol, D-68167 Mannheim, Germany
[3] Vrije Univ Amsterdam, Ctr Med, Dept Cardiol, Amsterdam, Netherlands
关键词
D O I
10.1148/radiol.2353040601
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To prospectively assess the effect of including or excluding endocardial trabeculae in left ventricular (LV) measurements and the reproducibility of these measurements at cine cardiovascular magnetic resonance (MR) imaging with true fast imaging with steady-state precession (FISP). MATERIALS AND METHODS: The study was approved by the local ethics committee, and each subject gave informed consent before participating. Twenty healthy subjects and 20 consecutive patients underwent 1.5-T cardiovascular MR imaging. Seven to 12 short-axis views encompassing the entire LV were acquired by using true FISP. Endocardial and epicardial contours were traced manually. The data sets in each patient were analyzed twice: with inclusion of endocardial trabeculae in the LV cavity volume and with exclusion of endocardial trabeculae from the cavity volume. On the basis of these two contour sets, the end-diastolic (ED) and endsystolic (ES) LV volumes, ejection fraction (EF), and LV mass were calculated. Additionally, interobserver and interexamination reproducibility was assessed by using Bland-Altman analysis. RESULTS: Compared with exclusion of trabeculae, inclusion of trabeculae in the LV cavity volume resulted in significantly larger ED and ES LV volumes (mean differences, 21 mL +/- 11 [standard deviation] and 19 mL +/- 33, respectively; P <.001) and lower EFs (mean difference, -2% +/- 2; P <.001). The calculated LV mass was significantly smaller with inclusion than with exclusion of trabeculae (mean difference, -21 g +/- 12; P <.001), All interobserver and interexamination limits of agreement based on inclusion of trabeculae, except those for EF measurements, were superior to those based on exclusion of trabeculae. At measurement reproducibility comparisons, differences in interobserver ED LV volume and LV mass and interexamination LV mass were statistically significant, favoring the inclusion of trabeculae in the LV cavity volume. CONCLUSION: Trabeculae significantly affect quantifications of LV volume and mass. The superior reproducibility of LV measurements with the inclusion of endocardial trabeculae in the cavity volume favors this tracing algorithm for clinical use. ((c)) RSNA, 2005.
引用
收藏
页码:57 / 64
页数:8
相关论文
共 50 条
  • [21] Reproducibility of left and right ventricular mass measurements with cardiac CT
    Schwarz, Florian
    Takx, Richard
    Schoepf, U. Joseph
    Lee, Yeong Shyan
    Ruzsics, Balazs
    Gassner, Eva Maria
    Chiaramida, Salvatore
    Henzler, Thomas
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2011, 5 (05) : 317 - 324
  • [22] Left ventricular ejection fraction measurement using cardiovascular magnetic resonance imaging in patients with post-myocardial infarction: assessment of reproducibility by a cardiovascular radiologist and a trained technologist
    Tumkosit, Monravee
    Detphirattanamongkhol, Juthamas
    Kuadwongsa, Achara
    Srimahachota, Suphot
    Kitsukjit, Weeranuch
    Wangsuphachart, Somjai
    ASIAN BIOMEDICINE, 2011, 5 (04) : 543 - 548
  • [23] Effect of temporal resolution on the estimation of left ventricular function by cardiac MR imaging
    Inoue, Y
    Nomura, Y
    Nakaoka, T
    Watanabe, M
    Kiryu, S
    Okubo, T
    Ohtomo, K
    MAGNETIC RESONANCE IMAGING, 2005, 23 (05) : 641 - 645
  • [24] Inter-study reproducibility of left ventricular structure and function in heart failure patients with cine MR imaging
    Panse, PM
    Muehling, O
    Zenovich, A
    Panse, N
    Seethamraju, R
    Huang, YM
    Swingen, C
    Jerosch-Herold, M
    Wilke, N
    Anand, I
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (02) : 207A - 207A
  • [25] A study on reproducibility and validation of the measurement of left ventricular ejection fraction
    Esquerre, JP
    MEDECINE NUCLEAIRE, 1997, 21 (02): : 98 - 102
  • [26] Cardiovascular imaging of a giant left ventricular aneurysm
    Sousa da Silva, Gustavo Lima
    da Silva Carvalheiro, Catarina Alexandra
    Cardoso, Pedro Pinto
    Abreu Arruda Pereira, Ricardo Joao
    Pereira Nobre, Angelo Lucas
    Gomes de Almeida, Ana Maria
    REVISTA PORTUGUESA DE CARDIOLOGIA, 2015, 34 (7-8) : 501 - 503
  • [27] Measurement of regional aortic compliance by MR imaging: A study of reproducibility
    Forbat, SM
    Mohiaddin, RH
    Yang, GZ
    Firmin, DN
    Underwood, SR
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (06): : 635 - 639
  • [28] MEASUREMENT OF RIGHT AND LEFT-VENTRICULAR VOLUMES IN HEALTHY-INDIVIDUALS WITH CINE MR IMAGING
    SECHTEM, U
    PFLUGFELDER, PW
    GOULD, RG
    CASSIDY, MM
    HIGGINS, CB
    RADIOLOGY, 1987, 163 (03) : 697 - 702
  • [29] MR imaging of isolated left ventricular apical hypoplasia
    Carlos Marin
    Maria Luisa Sanchez
    Enrique Maroto
    Silvia Ossaba
    Yolanda Ruiz
    Juan I. Zabala
    Pediatric Radiology, 2007, 37 : 703 - 705
  • [30] MR imaging of isolated left ventricular apical hypoplasia
    Marin, Carlos
    Sanchez, Maria Luisa
    Maroto, Enrique
    Ossaba, Silvia
    Ruiz, Yolanda
    Zabala, Juan I.
    PEDIATRIC RADIOLOGY, 2007, 37 (07) : 703 - 705