TISSUE-GROWTH INTO POROUS-COATED ACETABULAR COMPONENTS IN 42 PATIENTS - EFFECTS OF ADJUNCT FIXATION

被引:0
|
作者
COOK, SD
THOMAS, KA
BARRACK, RL
WHITECLOUD, TS
机构
关键词
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Histologic examination was performed on 42 uncemented, porous-coated acetabular components removed for reasons not related to fixation. Included were 20 devices that had fixed pegs or spikes to aid in initial fixation and 22 devices that used screws through the component. The diagnoses and patient ages at insertion, times in situ, and reasons for removal were comparable for the two groups. Bone ingrowth was observed in 28 of the 42 acetabular components (67%). Of the 20 components with pegs or spikes, nine had no bone ingrowth, six had minimal bone ingrowth, four had moderate ingrowth, and one had extensive bone ingrowth. Of the 22 components with screws, five had no bone ingrowth, six had minimal bone ingrowth, six had moderate bone ingrowth, and five had extensive bone ingrowth. Two of the devices with screws also had external threads on the metallic shell; neither had any bone ingrowth, and the two accounted for two of the five devices having no bone ingrowth in this group. Bone ingrowth occurred more frequently, in greater amounts and was more evenly distributed anatomically in cups using screws for initial adjunct fixation. Roentgenographic and clinical findings were unreliable in predicting ingrowth of bone.
引用
收藏
页码:163 / 170
页数:8
相关论文
共 33 条
  • [21] The Harris-Galante porous-coated acetabular component with screw fixation - An average ten-year follow-up study
    Clohisy, JC
    Harris, WH
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (01): : 66 - 73
  • [22] Analysis of temporal wear patterns of porous-coated acetabular components: Distinguishing between true wear and so-called bedding-in
    Sychterz, CJ
    Engh, CA
    Yang, A
    Engh, CA
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (06): : 821 - 830
  • [23] Analysis of Migration of Press-Fit Porous-Coated Acetabular Components With Medial Lucencies Using Ein-Bild-Roentegen-Analyse
    Sadeghi, Cameron
    Gibson, Anthony G.
    Ries, Michael D.
    JOURNAL OF ARTHROPLASTY, 2012, 27 (07): : 1354 - 1357
  • [24] THE HARRIS-GALANTE POROUS-COATED ACETABULAR COMPONENT WITH SCREW FIXATION - RADIOGRAPHIC ANALYSIS OF 83 PRIMARY HIP REPLACEMENTS AT A MINIMUM OF 5 YEARS
    SCHMALZRIED, TP
    HARRIS, WH
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (08): : 1130 - 1139
  • [25] Medial protrusio technique for placement of a porous-coated, hemispherical acetabular component without cement in a total hip arthroplasty in patients who have acetabular dysplasia
    Dorr, LD
    Tawakkol, S
    Moorthy, M
    Long, W
    Wan, ZN
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (01): : 83 - 92
  • [26] Cemented tibial component fixation performs better than cementless fixation -: A randomized radiostereometric study comparing porous-coated, hydroxyapatite-coated and cemented tibial components over 5 years
    Carlsson, Å
    Björkman, A
    Besjakov, J
    Önsten, I
    ACTA ORTHOPAEDICA, 2005, 76 (03) : 362 - 369
  • [27] BONE INGROWTH AND WEAR DEBRIS IN WELL-FIXED CEMENTLESS POROUS-COATED TIBIAL COMPONENTS REMOVED FROM PATIENTS
    SUMNER, DR
    KIENAPFEL, H
    JACOBS, JJ
    URBAN, RM
    TURNER, TM
    GALANTE, JO
    JOURNAL OF ARTHROPLASTY, 1995, 10 (02): : 157 - 167
  • [28] Cemented polyethylene and cementless porous-coated acetabular components have similar outcomes at a mean of seven years after total hip replacement A PROSPECTIVE RANDOMISED STUDY
    Angadi, D. S.
    Brown, S.
    Crawfurd, E. J. P.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2012, 94B (12): : 1604 - 1610
  • [29] Midterm Results of a Contemporary, Porous-Coated Acetabular System in Patients Undergoing Primary Total Hip Replacement for Degenerative Hip Disease: A Prospective, Multicenter Study
    Wilson, Ian R.
    Turgeon, Thomas R.
    Gascoyne, Trevor C.
    Della Valle, Craig J.
    McCalden, Richard W.
    JOURNAL OF ARTHROPLASTY, 2020, 35 (07): : 1862 - 1867
  • [30] The use of bilobed porous-coated acetabular components without structural bone graft for type III acetabular defects in revision total hip arthroplasty - A prospective study with a minimum 2-year follow-up
    Moskal, JT
    Shen, FH
    JOURNAL OF ARTHROPLASTY, 2004, 19 (07): : 867 - 873