A NEW METHOD FOR THE RAPID-DETERMINATION OF IONIZED MG-2+ IN WHOLE-BLOOD, SERUM AND PLASMA

被引:0
|
作者
ALTURA, BT
SHIREY, TL
YOUNG, CC
HITI, J
DELLORFANO, K
HANDWERKER, SM
ALTURA, BM
机构
[1] NOVA BIOMED CORP, WALTHAM, MA USA
[2] BOOTH MEM MED CTR, DEPT OBSTET & GYNECOL, FLUSHING, NY USA
关键词
D O I
暂无
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
A novel ion selective electrode (ISE) for ionized magnesium (IMg2+) in whole blood (WB), plasma (PL) and serum (S) has now been designed and characterized in normal human subjects, diseased and pregnant subjects. Using this ISE on various levels of aqueous Mg2+ solutions (0.1-3.0mM), mean Mg2+ values are within 94.6 and 99.2% of their targets. The linearity of the ISE (0.1-3.OmM) in aqueous solution and human PL and S ranges between 92.0 and 99.3%. The ISE is highly selective for IMg2+, yielding measurements in less than 2 min, and exhibiting no or negligible effects from physiologic concentrations of Ca2+,Na+, K+ or H+. Ligand binding studies indicate that pathophysiologic concentrations of most smaller molecular weight anions fail to interfere with IMg2+ measurements in aqueous solution, PL or S. Likewise, pathophysiologic concentrations of heavy metals or lipids do not interfere with measurements for IMg2+. Comparison of healthy, normal WB, PL and S IMg2+, using the ISE, with measurements of ultrafilterable Mg by atomic absorption spectroscopy (AAS) are excellent. The mean value for IMg2+ in normal WB, PL and S is 0.58-0.60mM (range = 0.53-0.67mM). Compared to total Mg (TMg) (0. 75-0.96mM) and ICa2+ (1.10-1.30mM), IMg2+ is held in a narrow, tight range, representing 71% of TMg. Preliminary studies on plasma and serum IMg2+ during open heart surgery and term pregnancy demonstrate significant abnormalities in IMg2+ and % IMg2+. The new ISE for IMg2+ should prove invaluable and revolutionary in studies of Mg metabolism in both healthy and diseased states.
引用
收藏
页码:297 / 304
页数:8
相关论文
共 50 条
  • [21] RAPID-DETERMINATION OF 5-HYDROXYTRYPTAMINE IN WHOLE-BLOOD BY LIQUID-CHROMATOGRAPHY WITH FLUOROMETRIC DETECTION
    TRAIFFORT, E
    HUBERT, P
    TAYEB, N
    AYMARD, N
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 571 (1-2): : 231 - 234
  • [22] Ionized calcium: Whole blood, plasma or serum?
    Krahn, John
    Lou, Huiquan
    CLINICAL LABORATORY, 2008, 54 (5-6) : 185 - 189
  • [23] A NEW METHOD FOR THE RAPID-DETERMINATION OF AMANITA TOXINS IN THE URINE AND PLASMA
    FREI, W
    ANDRES, R
    GAUTSCHI, K
    VONDERSCHMITT, D
    SCHWEIZERISCHE MEDIZINISCHE WOCHENSCHRIFT, 1986, 116 (26) : 892 - 893
  • [24] IONIZED CALCIUM (CA2+) ELECTROMETRIC MEASUREMENT IN WHOLE-BLOOD AND PLASMA
    SACHS, C
    BOURDEAU, AM
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1972, 29 : 253 - &
  • [25] AUTOMATIC-MEASUREMENT OF SODIUM, POTASSIUM AND IONIZED CALCIUM IN MICROSAMPLES OF WHOLE-BLOOD, SERUM AND PLASMA
    MARSONER, HJ
    RITTER, C
    STRUTZ, W
    HARNONCOURT, K
    JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1981, 19 (08): : 762 - 763
  • [26] THE DIRECT DETERMINATION OF MERCURY IN WHOLE-BLOOD AND SERUM
    ROBINSON, JW
    SKELLY, EM
    SPECTROSCOPY LETTERS, 1983, 16 (01) : 59 - 76
  • [27] NEW HEMOLYTIC METHOD FOR DETERMINATION OF ANTISTREPTOLYSIN O IN WHOLE-BLOOD
    RICCI, A
    BERTI, B
    MOAURO, C
    PORRO, M
    NERI, P
    TARLI, P
    JOURNAL OF CLINICAL MICROBIOLOGY, 1978, 8 (03) : 263 - 267
  • [28] RAPID-DETERMINATION OF GOLD IN WHOLE-BLOOD OF ARTHRITIS PATIENTS USING FLAMELESS ATOMIC-ABSORPTION SPECTROPHOTOMETRY
    BARRETT, MJ
    DEFRIES, R
    HENDERSON, WM
    JOURNAL OF PHARMACEUTICAL SCIENCES, 1978, 67 (09) : 1332 - 1334
  • [29] METHOD FOR DETERMINATION OF TOTAL FLUORINE CONTENT OF WHOLE-BLOOD, SERUM-PLASMA, AND OTHER BIOLOGICAL SAMPLES
    BELISLE, J
    HAGEN, DF
    ANALYTICAL BIOCHEMISTRY, 1978, 87 (02) : 545 - 555
  • [30] METHOD FOR DETERMINATION OF PLATELET AND PLASMA MONOAMINE-OXIDASE IN WHOLE-BLOOD
    MARSHALL, EF
    CAMPBELL, IC
    BIOCHEMICAL PHARMACOLOGY, 1977, 26 (04) : 353 - 354