3-DIMENSIONAL BLACK BLOOD MR-ANGIOGRAPHY OF THE LIVER DURING BREATH-HOLDING - A COMPARISON WITH 2-DIMENSIONAL TIME-OF-FLIGHT MR-ANGIOGRAPHY

被引:0
|
作者
SUTO, Y [1 ]
OHUCHI, Y [1 ]
KIMURA, T [1 ]
SHIRAKAWA, T [1 ]
MIZUUCHI, N [1 ]
TAKIZAWA, O [1 ]
YAMANE, T [1 ]
KAMBA, M [1 ]
MORIYAMA, S [1 ]
OHTA, Y [1 ]
机构
[1] SIEMENS ASAHI MED TECHNOL LTD,TOKYO,JAPAN
关键词
MR; VASCULAR STUDIES; COMPARATIVE STUDIES; 3-DIMENSIONAL; LIVER; PORTAL VEIN;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In 2-D time-of-flight MR angiography (2-D TOF MRA) of the liver, artifacts caused by respiratory motion are unavoidable. Therefore, a 3-D black blood MRA of the liver was attempted in 7 healthy volunteers, using a 3-D gradient echo sequence which allows imaging during breath holding. 2-D TOF MRA was performed as well. In all subjects, 3-D MRA allowed visualization of the trunk, 1st-, and 2nd-order branches of the portal vein without interruption. Right 3rd-order branches were visualized without interruption in 6 of 7 subjects (85%). However, with 2-D MRA, the transverse portion of the left main portal vein could not be visualized in any subject, and the periphery of the portal vein was less clear than with 3-D MRA.
引用
收藏
页码:131 / 134
页数:4
相关论文
共 50 条
  • [21] PULSATILE FLOW ARTIFACTS IN 2-DIMENSIONAL TIME-OF-FLIGHT MR-ANGIOGRAPHY - INITIAL STUDIES IN ELASTIC MODELS OF HUMAN CAROTID ARTERIES
    BUXTON, RB
    KERBER, CW
    FRANK, LR
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (04): : 625 - 636
  • [22] INTRACRANIAL VASCULAR STENOSIS AND OCCLUSION - DIAGNOSTIC-ACCURACY OF 3-DIMENSIONAL, FOURIER-TRANSFORM, TIME-OF-FLIGHT MR-ANGIOGRAPHY
    KOROGI, Y
    TAKAHASHI, M
    MABUCHI, N
    MIKI, H
    SHIGA, H
    WATABE, T
    OUCHI, T
    NAKAGAWA, T
    HORIKAWA, Y
    FUJIWARA, S
    FURUSE, M
    RADIOLOGY, 1994, 193 (01) : 187 - 193
  • [23] 3-DIMENSIONAL TIME-OFF-FLIGHT MR-ANGIOGRAPHY WITH VARIABLE TE (VARIETE) FOR FAT SIGNAL REDUCTION
    LIN, WL
    HAACKE, EM
    TKACH, JA
    MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (05) : 678 - 683
  • [24] TIME-OF-FLIGHT MR-ANGIOGRAPHY OF THE BRAIN - COMPARISON OF ACQUISITION TECHNIQUES IN HEALTHY-VOLUNTEERS
    BOSMANS, H
    MARCHAL, G
    LUKITO, G
    YICHENG, N
    WILMS, G
    LAUB, G
    BAERT, AL
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 164 (01) : 161 - 167
  • [25] CONTRAST-ENHANCED 3-DIMENSIONAL MR-ANGIOGRAPHY IN A SINGLE BREATH-HOLD - A NOVEL TECHNIQUE
    SHETTY, AN
    SHIRKHODA, A
    BIS, KG
    ALCANTARA, A
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (05) : 1290 - 1292
  • [26] 2-DIMENSIONAL CORONARY MR-ANGIOGRAPHY - ANALYSIS OF INITIAL CLINICAL-RESULTS
    DUERINCKX, AJ
    URMAN, MK
    RADIOLOGY, 1994, 193 (03) : 731 - 738
  • [27] 3-DIMENSIONAL PHASE-CONTRAST MR-ANGIOGRAPHY OF THE RENAL-ARTERIES - COMPARISON WITH AORTOGRAPHY
    GOMES, AS
    YOON, H
    FLAMM, SD
    GOODWIN, SC
    RADIOLOGY, 1995, 197 : 214 - 214
  • [28] 3-DIMENSIONAL STEADY-STATE MR-ANGIOGRAPHY OF THE LOWER-EXTREMITIES
    SCHMALBROCK, P
    HACKER, VA
    RAO, A
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (02): : 223 - 230
  • [29] SEQUENTIAL 3-DIMENSIONAL TIME-OF-FLIGHT MR-ANGIOGRAPHY OF THE CAROTID ARTERIES - VALUE OF VARIABLE EXCITATION AND POSTPROCESSING IN REDUCING VENETIAN BLIND ARTIFACT
    DING, XP
    TKACH, JA
    RUGGIERI, PR
    MASARYK, TJ
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (03) : 683 - 688
  • [30] MOYAMOYA DISEASE - DIAGNOSIS WITH 3-DIMENSIONAL TIME-OF-FLIGHT MR ANGIOGRAPHY
    YAMADA, I
    MATSUSHIMA, Y
    SUZUKI, S
    RADIOLOGY, 1992, 184 (03) : 773 - 778