3-DIMENSIONAL STEADY-STATE MR-ANGIOGRAPHY OF THE LOWER-EXTREMITIES

被引:6
|
作者
SCHMALBROCK, P
HACKER, VA
RAO, A
机构
[1] Department of Radiology, MRI Facility, Ohio State University, Columbus, Ohio, 43210
来源
关键词
ARTERIES; EXTREMITIES; IMAGE DISPLAY; IMAGE PROCESSING; PULSE SEQUENCES; 3-DIMENSIONAL IMAGING; VASCULAR STUDIES; VEINS;
D O I
10.1002/jmri.1880040222
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Volume steady-state black-blood magnetic resonance imaging was evaluated as a method for depicting lower extremity vasculature. In steady-state imaging, flow has low signal intensity because motion destroys the coherence of transverse magnetization. To optimize image contrast, computations and measurements were obtained for the three-dimensional (3D) GRASS (gradient-recalled acquisition in the steady state) and 3D SSFP (steady-state free precession) sequences and a range of TRs and flip angles to determine optimal vessel-muscle contrast. The best results were achieved with a 3D GRASS sequence with a TR msec/TE msec of 25/5 and a flip angle of 30-degrees. Coronal images of the femoral and popliteal vessels were obtained in healthy volunteers with various fields of view and voxel sizes. Inflow of unsaturated spins from outside the image region, yielding high signal intensity, could be a potential drawback in steady-state black-blood imaging; however, problems can be avoided by using coronal acquisitions and large fields of view. Steady-state black-blood imaging depicts vessels with high accuracy and is faster and free of flow artifacts.
引用
收藏
页码:223 / 230
页数:8
相关论文
共 50 条
  • [1] LOWER-EXTREMITIES - MR-ANGIOGRAPHY WITH A UNILATERAL TELESCOPIC PHASED-ARRAY COIL
    KOJIMA, KY
    SZUMOWSKI, J
    SHELEY, RC
    QUINN, SF
    [J]. RADIOLOGY, 1995, 196 (03) : 871 - 875
  • [2] MR-ANGIOGRAPHY VERSUS CONVENTIONAL X-RAY ANGIOGRAPHY IN THE LOWER-EXTREMITIES - EVERYONE WINS
    BORRELLO, JA
    [J]. RADIOLOGY, 1993, 187 (03) : 615 - 617
  • [3] VESSEL ENHANCEMENT FILTERING IN 3-DIMENSIONAL MR-ANGIOGRAPHY
    DU, YP
    PARKER, DL
    DAVIS, WL
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (02): : 151 - 157
  • [4] VESSEL ENHANCEMENT FILTERING IN 3-DIMENSIONAL MR-ANGIOGRAPHY
    DU, YPP
    PARKER, DL
    DAVIS, WL
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (03): : 353 - 359
  • [5] MR GATED SUBTRACTION ANGIOGRAPHY - EVALUATION OF LOWER-EXTREMITIES
    MEULI, RA
    WEDEEN, VJ
    GELLER, SC
    EDELMAN, RR
    FRANK, LR
    BRADY, TJ
    ROSEN, BR
    [J]. RADIOLOGY, 1986, 159 (02) : 411 - 418
  • [6] NONLINEAR EXCITATION PROFILES FOR 3-DIMENSIONAL INFLOW MR-ANGIOGRAPHY
    NAGELE, T
    KLOSE, U
    GRODD, W
    NUSSLIN, F
    VOIGT, K
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (04): : 416 - 420
  • [7] 3-DIMENSIONAL MR OF THE INNER-EAR WITH STEADY-STATE FREE PRECESSION
    GUIRADO, CR
    MARTINEZ, P
    ROIG, R
    MIROSA, F
    SALMERON, J
    FLORENSA, F
    ROGER, M
    BARRAGAN, Y
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 1995, 16 (09) : 1909 - 1913
  • [8] DYNAMIC CONTRAST-ENHANCED SUBTRACTION MR-ANGIOGRAPHY OF THE LOWER-EXTREMITIES - INITIAL EVALUATION WITH A MULTISECTION 2-DIMENSIONAL TIME-OF-FLIGHT SEQUENCE
    ADAMIS, MK
    LI, W
    WIELOPOLSKI, PA
    KIM, D
    SAX, EJ
    KENT, KC
    EDELMAN, RR
    [J]. RADIOLOGY, 1995, 196 (03) : 689 - 695
  • [9] 3-DIMENSIONAL STEADY-STATE MAGNETIC RECONNECTION
    JARDINE, M
    [J]. JOURNAL OF PLASMA PHYSICS, 1994, 51 : 399 - 422
  • [10] ACETAZOLAMIDE CHALLENGE FOR 3-DIMENSIONAL TIME-OF-FLIGHT MR-ANGIOGRAPHY OF THE BRAIN
    MANDAI, K
    SUEYOSHI, K
    FUKUNAGA, R
    NUKADA, M
    OHTANI, F
    ARAKI, Y
    TSUKAGUCHI, I
    ABE, H
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 1994, 15 (04) : 659 - 665