3-DIMENSIONAL STEADY-STATE MR-ANGIOGRAPHY OF THE LOWER-EXTREMITIES

被引:6
|
作者
SCHMALBROCK, P
HACKER, VA
RAO, A
机构
[1] Department of Radiology, MRI Facility, Ohio State University, Columbus, Ohio, 43210
来源
关键词
ARTERIES; EXTREMITIES; IMAGE DISPLAY; IMAGE PROCESSING; PULSE SEQUENCES; 3-DIMENSIONAL IMAGING; VASCULAR STUDIES; VEINS;
D O I
10.1002/jmri.1880040222
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Volume steady-state black-blood magnetic resonance imaging was evaluated as a method for depicting lower extremity vasculature. In steady-state imaging, flow has low signal intensity because motion destroys the coherence of transverse magnetization. To optimize image contrast, computations and measurements were obtained for the three-dimensional (3D) GRASS (gradient-recalled acquisition in the steady state) and 3D SSFP (steady-state free precession) sequences and a range of TRs and flip angles to determine optimal vessel-muscle contrast. The best results were achieved with a 3D GRASS sequence with a TR msec/TE msec of 25/5 and a flip angle of 30-degrees. Coronal images of the femoral and popliteal vessels were obtained in healthy volunteers with various fields of view and voxel sizes. Inflow of unsaturated spins from outside the image region, yielding high signal intensity, could be a potential drawback in steady-state black-blood imaging; however, problems can be avoided by using coronal acquisitions and large fields of view. Steady-state black-blood imaging depicts vessels with high accuracy and is faster and free of flow artifacts.
引用
收藏
页码:223 / 230
页数:8
相关论文
共 50 条
  • [41] IS HELICITY RELEVANT FOR LARGE-SCALE STEADY-STATE 3-DIMENSIONAL TURBULENCE
    POUQUET, A
    FOURNIER, JD
    SULEM, PL
    [J]. JOURNAL DE PHYSIQUE LETTRES, 1978, 39 (13): : L199 - L203
  • [43] Renal arteries: Comparison of steady-state free precession MR angiography and contrast-enhanced MR angiography
    Herborn, CU
    Watkins, DM
    Runge, VM
    Gendron, JM
    Montgomery, ML
    Naul, LG
    [J]. RADIOLOGY, 2006, 239 (01) : 263 - 268
  • [44] INTRACRANIAL ANEURYSMS - ENDOVASCULAR EVALUATION WITH 3-DIMENSIONAL-DISPLAY MR-ANGIOGRAPHY
    BONTOZOGLOU, NP
    SPANOS, H
    LASJAUNIAS, P
    ZARIFIS, G
    [J]. RADIOLOGY, 1995, 197 (03) : 876 - 879
  • [45] INTRACRANIAL ANEURYSMS - DIAGNOSTIC-ACCURACY OF 3-DIMENSIONAL, FOURIER-TRANSFORM, TIME-OF-FLIGHT MR-ANGIOGRAPHY
    KOROGI, Y
    TAKAHASHI, M
    MABUCHI, N
    MIKI, H
    FUJIWARA, S
    HORIKAWA, Y
    NAKAGAWA, T
    OUCHI, T
    WATABE, T
    SHIGA, H
    FURUSE, M
    [J]. RADIOLOGY, 1994, 193 (01) : 181 - 186
  • [46] ULTRASONIC ANGIOGRAPHY IN DIAGNOSTICS OF OCCLUDING DISEASES OF MAJOR ARTERIES OF LOWER-EXTREMITIES
    LAPIN, MD
    DUDKIN, BP
    DOLGIKH, VA
    VORONTSOV, VV
    [J]. VESTNIK KHIRURGII IMENI I I GREKOVA, 1988, 141 (09): : 32 - 34
  • [47] MAGNETIC-RESONANCE ANGIOGRAPHY OF THE PELVIS AND LOWER-EXTREMITIES - WORKS IN PROGRESS
    SCHIEBLER, ML
    LISTERUD, J
    HOLLAND, G
    OWEN, R
    BAUM, R
    KRESSEL, HY
    [J]. INVESTIGATIVE RADIOLOGY, 1992, 27 : S90 - S96
  • [48] RAPID 3-DIMENSIONAL ANGIOGRAPHY WITH UNDERSAMPLED MR IMAGING
    WEDEEN, VJ
    CHAO, YS
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1987, 11 (01) : 24 - 30
  • [49] 3-DIMENSIONAL TEMPERATURE DISTRIBUTION WITHIN A STEADY-STATE CROSS-FLOW ARC
    BENENSON, DM
    CENKNER, AA
    BAKER, AJ
    [J]. BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1970, 15 (03): : 414 - &
  • [50] A NOVEL 3-DIMENSIONAL PRESENTATION OF STEADY-STATE RESPONSE OF A SIMPLE DAMPED LINEAR OSCILLATOR
    BUTTERFI.R
    [J]. JOURNAL OF APPLIED MECHANICS, 1968, 35 (01): : 181 - &