DOSE UNIFORMITY IN SCANNED FOCUSED ULTRASOUND HYPERTHERMIA

被引:21
|
作者
LAGENDIJK, JJW [1 ]
CREZEE, J [1 ]
HAND, JW [1 ]
机构
[1] HAMMERSMITH HOSP,ROYAL POSTGRAD MED SCH,DEPT PHYS MED,LONDON W12 0NN,ENGLAND
关键词
D O I
10.3109/02656739409012370
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Scanned focused ultrasound (SFUS) is unique amongst noninvasive methods of inducing hyperthermia in that the absorbed power (SAR) distribution may be controlled at a scale of 0.5 cm or better. This high degree of spatial control of SAR implies that differences in local tissue cooling due to heterogeneity in perfusion, variations in the density of discrete thermally significant vessels and even local cooling around single large vessels may be compensated during SFUS treatments. In this paper we calculate thermal dose distributions arising from three different SFUS techniques: (1) the high-temperature short-duration (HTSD) ultrasound technique; (2) conventional systems employing a fixed scan and fixed SAR simulated by a uniform SAR; and (3) we optimize the SAR distribution using information from angiography and thermal models. These techniques are tested in the same anatomy having discrete vessels, a non-uniform vessel density and with little, if any, preheating of the incoming blood (i.e. the worst-case situation). The application of a uniform SAR to this volume resulted in a highly nonuniform thermal dose distribution. The situation is clearly improved in HTSD hyperthermia; however, the desired accuracy of positioning within the tumour is high, and to minimize background heating the focus must be stepped slowly and preferably in a semi-random pattern through the target volume. The third technique which employs spatial control over SAR resulted in the greatest uniformity in thermal dose. However, the use of this technique requires the input of the complete three-dimensional discrete vessel network and the availability of a tested three-dimensional discrete vessel thermal model.
引用
收藏
页码:775 / 784
页数:10
相关论文
共 50 条
  • [1] FOCUSED, SCANNED ULTRASOUND FOR LOCAL HYPERTHERMIA
    HYNYNEN, K
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1985, 32 (10) : 877 - 877
  • [2] Control of scanned, focused ultrasound hyperthermia treatments
    Lin, Win-Li
    Wang, C.Y.
    Shieh, M.J.
    Biomedical Engineering - Applications, Basis and Communications, 1992, 4 (06): : 618 - 625
  • [3] NONLINEAR ABSORPTION DURING SCANNED FOCUSED ULTRASOUND HYPERTHERMIA
    HYNYNEN, K
    ROEMER, RB
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1986, 33 (01) : 107 - 107
  • [4] OPTIMIZATION OF TEMPERATURE DISTRIBUTIONS IN SCANNED, FOCUSED ULTRASOUND HYPERTHERMIA
    LIN, WL
    ROEMER, RB
    MOROS, EG
    HYNYNEN, K
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1992, 8 (01) : 61 - 78
  • [6] SCANNED FOCUSED ULTRASOUND HYPERTHERMIA - INITIAL CLINICAL-RESULTS
    SHIMM, DS
    HYNYNEN, KH
    ANHALT, DP
    ROEMER, RB
    CASSADY, JR
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1988, 15 (05): : 1203 - 1208
  • [7] EARLY EXPERIENCE OF A COMMERCIAL SCANNED FOCUSED ULTRASOUND HYPERTHERMIA SYSTEM
    HAND, JW
    VERNON, CC
    PRIOR, MV
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1992, 8 (05) : 587 - 607
  • [8] HYPERTHERMIA TREATMENT OF BRAIN-TUMORS USING SCANNED, FOCUSED ULTRASOUND
    ROEMER, RB
    HYNYNEN, K
    TOBIAS, J
    FLEISHER, A
    GUTHKELCH, AN
    TOBIAS, J
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1987, 3 (06) : 588 - 588
  • [9] MULTIPOINT FEEDBACK-CONTROL SYSTEM FOR SCANNED, FOCUSED ULTRASOUND HYPERTHERMIA
    JOHNSON, C
    KRESS, R
    ROEMER, R
    HYNYNEN, K
    PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (06): : 781 - 786
  • [10] DEVELOPMENT OF SCANNED FOCUSED ULTRASOUND HYPERTHERMIA - CLINICAL-RESPONSE EVALUATION
    HARARI, PM
    HYNYNEN, KH
    ROEMER, RB
    ANHALT, DP
    SHIMM, DS
    STEA, B
    CASSADY, JR
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (03): : 831 - 840