DOSE UNIFORMITY IN SCANNED FOCUSED ULTRASOUND HYPERTHERMIA

被引:21
|
作者
LAGENDIJK, JJW [1 ]
CREZEE, J [1 ]
HAND, JW [1 ]
机构
[1] HAMMERSMITH HOSP,ROYAL POSTGRAD MED SCH,DEPT PHYS MED,LONDON W12 0NN,ENGLAND
关键词
D O I
10.3109/02656739409012370
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Scanned focused ultrasound (SFUS) is unique amongst noninvasive methods of inducing hyperthermia in that the absorbed power (SAR) distribution may be controlled at a scale of 0.5 cm or better. This high degree of spatial control of SAR implies that differences in local tissue cooling due to heterogeneity in perfusion, variations in the density of discrete thermally significant vessels and even local cooling around single large vessels may be compensated during SFUS treatments. In this paper we calculate thermal dose distributions arising from three different SFUS techniques: (1) the high-temperature short-duration (HTSD) ultrasound technique; (2) conventional systems employing a fixed scan and fixed SAR simulated by a uniform SAR; and (3) we optimize the SAR distribution using information from angiography and thermal models. These techniques are tested in the same anatomy having discrete vessels, a non-uniform vessel density and with little, if any, preheating of the incoming blood (i.e. the worst-case situation). The application of a uniform SAR to this volume resulted in a highly nonuniform thermal dose distribution. The situation is clearly improved in HTSD hyperthermia; however, the desired accuracy of positioning within the tumour is high, and to minimize background heating the focus must be stepped slowly and preferably in a semi-random pattern through the target volume. The third technique which employs spatial control over SAR resulted in the greatest uniformity in thermal dose. However, the use of this technique requires the input of the complete three-dimensional discrete vessel network and the availability of a tested three-dimensional discrete vessel thermal model.
引用
收藏
页码:775 / 784
页数:10
相关论文
共 50 条
  • [21] Investigation of a scanned cylindrical ultrasound system for breast hyperthermia
    Ju, KC
    Tseng, LT
    Chen, YY
    Lin, WL
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (03): : 539 - 555
  • [22] THE DESIGN OF FOCUSED TRANSDUCERS FOR ULTRASOUND HYPERTHERMIA
    DICKINSON, RJ
    HAND, JW
    LEEMAN, S
    IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1983, 30 (03): : 200 - 200
  • [23] FOCUSED ULTRASOUND HYPERTHERMIA - MODELING AND CONTROL
    COOPER, DM
    KETTERER, FD
    FERRANTE, JG
    RADIATION RESEARCH, 1983, 94 (03) : 580 - 580
  • [24] USE OF FOCUSED FIELDS IN ULTRASOUND HYPERTHERMIA
    DICKINSON, RJ
    LEEMAN, S
    HAND, JW
    STRAHLENTHERAPIE, 1982, 158 (06) : 381 - 381
  • [25] FOCUSED ULTRASOUND HYPERTHERMIA - MODELING AND MEASUREMENT
    HIGGINS, PD
    ZAGZEBSKI, JA
    MADSEN, EL
    PALIWAL, BR
    FELMLEY, J
    MEDICAL PHYSICS, 1982, 9 (04) : 631 - 631
  • [26] A scanned, focused, multiple transducer ultrasonic system for localized hyperthermia treatments
    Hynynen, K.
    Roemer, R.
    Anhalt, D.
    Johnson, C.
    Xu, Z. X.
    Swindell, W.
    Cetas, T.
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2010, 26 (01) : 1 - 11
  • [27] A SCANNED, FOCUSED, MULTIPLE TRANSDUCER ULTRASONIC SYSTEM FOR LOCALIZED HYPERTHERMIA TREATMENTS
    HYNYNEN, K
    ROEMER, R
    ANHALT, D
    JOHNSON, C
    XU, ZX
    SWINDELL, W
    CETAS, T
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1987, 3 (01) : 21 - 35
  • [28] Influence of Magnetic Nanoparticles on the Focused Ultrasound Hyperthermia
    Kaczmarek, Katarzyna
    Hornowski, Tomasz
    Dobosz, Bernadeta
    Jozefczak, Arkadiusz
    MATERIALS, 2018, 11 (09)
  • [29] SPATIAL DOSE UNIFORMITY MONITOR FOR ELECTRICALLY SCANNED ION-BEAM
    NATSUAKI, N
    OHYU, K
    TOKUYAMA, T
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1978, 49 (09): : 1300 - 1304
  • [30] CLINICAL-EVALUATION OF LOCAL HYPERTHERMIA BY FOCUSED ULTRASOUND
    LELE, PP
    BERTINO, JR
    ERVIN, TJ
    FELDMAN, MI
    FREI, E
    KOWAL, CD
    BRITISH JOURNAL OF CANCER, 1982, 45 : 248 - 248