Implementation of compensator-based intensity modulated radiotherapy with a conventional telecobalt machine using missing tissue approach

被引:0
|
作者
Tagoe, Samuel N. A. [1 ,2 ]
Mensah, Samuel Y. [2 ]
Fletcher, John J. [3 ]
机构
[1] Korle Bu Teaching Hosp, Natl Ctr Radiotherapy & Nucl Med, Accra, Ghana
[2] Univ Cape Coast, Coll Agr & Nat Sci, Sch Phys Sci, Dept Phys, Cape Coast, Ghana
[3] Univ Dev Studies, Dept Appl Phys, Navrongo Campus, Navrongo, Ghana
来源
关键词
telecobalt machine; bolus; compensator; Gafchromic film; intensity modulated;
D O I
10.2478/pjmpe-2018-0024
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: The present study aimed to generate intensity-modulated beams with compensators for a conventional telecobalt machine, based on dose distributions generated with a treatment planning system (TPS) performing forward planning, and cannot directly simulate a compensator. Materials and Methods: The following materials were selected for compensator construction: Brass, Copper and Perspex (PMMA). Boluses with varying thicknesses across the surface of a tissue-equivalent phantom were used to achieve beam intensity modulations during treatment planning with the TPS. Beam data measured for specific treatment parameters in a full scatter water phantom with a 0.125 cc cylindrical ionization chamber, with a particular compensator material in the path of beams from the telecobalt machine, and that without the compensator but the heights of water above the detector adjusted to get the same detector readings as before, were used to develop and propose a semiempirical equation for converting a bolus thickness to compensator material thickness, such that any point within the phantom would receive the planned dose. Once the dimensions of a compensator had been determined, the compensator was constructed using the cubic pile method. The treatment plans generated with the TPS were replicated on the telecobalt machine with a bolus within each beam represented with its corresponding compensator mounted on the accessory holder of the telecobalt machine. Results: Dose distributions measured in the tissue-equivalent phantom with calibrated Gafchromic EBT2 films for compensators constructed based on the proposed approach, were comparable to those of the TPS with deviation less than or equal to +/- 3% (mean of 2.29 +/- 0.61%) of the measured doses, with resultant confidence limit value of 3.21. Conclusion: The use of the proposed approach for clinical application is recommended, and could facilitate the generation of intensity-modulated beams with limited resources using the missing tissue approach rendering encouraging results.
引用
下载
收藏
页码:171 / 179
页数:9
相关论文
共 50 条
  • [1] COMPENSATOR-BASED INTENSITY MODULATED BRACHYTHERAPY
    Flynn, R.
    Kim, Y.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S60 - S61
  • [2] Compensator-Based Intensity Modulated Brachytherapy for Cervical Cancer
    Flynn, R. T.
    Kim, Y.
    Jacobson, G. M.
    Wu, X.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [3] Investigation of Intensity Modulated Compensator-Based TBI for Small Children
    Sample, S.
    Wichman, B.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [4] Implementation of the tungsten-compensator based intensity-modulated radiotherapy (IMRT)
    Lian, J
    Chang, S
    Cullip, T
    Deschesne, K
    Schreiber, E
    Gardner, W
    Potter, L
    Euliss, W
    MEDICAL PHYSICS, 2005, 32 (06) : 1973 - 1973
  • [5] EBT GAFCHROMIC™ film dosimetry in compensator-based intensity modulated radiation therapy
    Vaezzadeh, Seyedali
    Allahverdi, Mahmoud
    Nedaie, Hasan A.
    Ay, Mohammadreza
    Shirazi, Alireza
    Yarahmadi, Mehran
    MEDICAL DOSIMETRY, 2013, 38 (02) : 176 - 183
  • [6] Preliminary clinical study on brass compensator-based intensity-modulated radiation therapy
    Li, Jie
    Qi, Guohai
    Qin, Yuan
    Wang, Pei
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2018, 14 (01) : 171 - 175
  • [7] Compensator-based intensity-modulated radiotherapy in head and neck cancer: Our experience in achieving dosimetric parameters and their clinical correlation
    Nangia, S.
    Chufal, K. S.
    Arivazhagan, V.
    Srinivas, P.
    Tyagi, A.
    Ghosh, D.
    CLINICAL ONCOLOGY, 2006, 18 (06) : 485 - 492
  • [8] Electronic compensator: a method to produce intensity modulated fields for missing tissue compensation
    Malatesta, T
    Bufacchi, A
    delle Canne, S
    Marmiroli, L
    Bonanni, A
    Caspiani, O
    Guidi, C
    Leone, MV
    Tortoreto, F
    Begnozzi, L
    RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S338 - S339
  • [9] The value of EDR2 film dosimetry in compensator-based intensity modulated radiation therapy
    Srivastava, R. P.
    DeWagter, C.
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (19): : N449 - N457
  • [10] Compensator-based intensity-modulated radiation therapy for malignant pleural mesothelioma post extrapleural pneumonectomy
    Javedan, Khosrow
    Stevens, Craig W.
    Forster, Kenneth M.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2008, 9 (04): : 98 - 109