MEAT AGING MEASUREMENT - COMPARISON BETWEEN 2 MECHANICAL METHODS

被引:0
|
作者
LEPETIT, J
BUFFIERE, C
机构
来源
FLEISCHWIRTSCHAFT | 1995年 / 75卷 / 10期
关键词
BEEF; TENDERNESS; MYOFIBRILLAR STRUCTURE; COMPRESSION;
D O I
暂无
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
The resistance of myofibrillar structure to a 0.2 strain was measured during ageing with two compressive methods on raw meat samples from old cows Longissimus Dorsi muscles. One measurement used a 10 Hz sinusoidal compression cycle performed on the Systeme d'Analyse de 1a Texture des Aliments. The other measurement used a classical linear compression system, with a probe speed of 50 mm/min. There was a close linear relationship (r = 0.96, P < 1 %) between the maximum stresses obtained in both methods. With linear compression, for a meat sample submitted to a 0.2 strain, myofibrillar structure developed a maximum stress which was about 35 N/cm(2) when measurements were done near rigor mortis. This value decreased to about 4 N/cm(2) when meat was aged. Theses values of stresses were slightly lower than those obtained with sinusoidal compression. The two methods were as suitable for measurement of meat ageing. Nevertheless they did not give exactly the same stresses values because samples were not tested with the same strain history in both method and meat has a slight speed-dependent mechanical behaviour.
引用
收藏
页码:1234 / &
相关论文
共 50 条
  • [42] COMPARISON OF 2 INVITRO AND 2 INVIVO METHODS FOR THE MEASUREMENT OF IRRITANCY
    STERZEL, W
    BARTNIK, FG
    MATTHIES, W
    KASTNER, W
    KUNSTLER, K
    TOXICOLOGY IN VITRO, 1990, 4 (4-5) : 698 - 701
  • [43] COMPARISON OF METHODS OF MAKING MECHANICAL PULP .2.
    BLECHSCHMIDT, J
    ZELLSTOFF UND PAPIER, 1975, 24 (12): : 367 - 370
  • [44] Measurement of the mechanical properties of the skin using the suction test - Comparison between three methods: geometric, Timoshenko and finite elements
    Khatyr, F
    Imberdis, C
    Varchon, D
    Lagarde, JM
    Josse, G
    SKIN RESEARCH AND TECHNOLOGY, 2006, 12 (01) : 24 - 31
  • [45] MEASUREMENT OF PLASMA DIGOXIN CONCENTRATION - COMPARISON OF 2 METHODS
    LADER, S
    BYE, A
    MARSDEN, P
    EUROPEAN JOURNAL OF CLINICAL PHARMACOLOGY, 1972, 5 (01) : 22 - &
  • [46] COMPARISON OF 2 MEASUREMENT METHODS FOR DETERMINATION OF ROTATIONAL MOBILITIES
    VANBAKEL, JG
    GERRETSEN, E
    ENGINEERING FOR ENVIRONMENTAL NOISE CONTROL, VOLS 1 AND 2: INTER-NOISE 89, 1989, : 535 - 538
  • [47] A COMPARISON OF 2 METHODS OF MEASUREMENT OF GASTRIC EMPTYING TIME
    CHERNISH, SM
    YOUNG, EB
    ROSENAK, BD
    REDMAN, CE
    AMERICAN JOURNAL OF DIGESTIVE DISEASES, 1967, 12 (08): : 761 - &
  • [48] COMPARISON OF 2 METHODS OF STRAIGHT LEG RAISE MEASUREMENT
    ROSEJACOBS, R
    GILBERTI, NC
    PHYSICAL THERAPY, 1985, 65 (05): : 716 - 716
  • [49] MEASUREMENT OF MYOCARDIAL INFARCT SIZE - COMPARISON OF 2 METHODS
    NORRIS, RM
    SMITH, HJ
    WHITLOCK, RM
    BARRATTB.C
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF MEDICINE, 1974, 4 (05): : 528 - 528
  • [50] COMPARISON OF 2 METHODS FOR MEASUREMENT OF THE MODAL POWER DISTRIBUTION
    AREFEV, EY
    BAMBULEVICH, KE
    GOLUB, MA
    KARPEEV, SV
    SISAKYAN, IN
    SOIFER, VA
    KVANTOVAYA ELEKTRONIKA, 1988, 15 (12): : 2467 - 2470