MEAT AGING MEASUREMENT - COMPARISON BETWEEN 2 MECHANICAL METHODS

被引:0
|
作者
LEPETIT, J
BUFFIERE, C
机构
来源
FLEISCHWIRTSCHAFT | 1995年 / 75卷 / 10期
关键词
BEEF; TENDERNESS; MYOFIBRILLAR STRUCTURE; COMPRESSION;
D O I
暂无
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
The resistance of myofibrillar structure to a 0.2 strain was measured during ageing with two compressive methods on raw meat samples from old cows Longissimus Dorsi muscles. One measurement used a 10 Hz sinusoidal compression cycle performed on the Systeme d'Analyse de 1a Texture des Aliments. The other measurement used a classical linear compression system, with a probe speed of 50 mm/min. There was a close linear relationship (r = 0.96, P < 1 %) between the maximum stresses obtained in both methods. With linear compression, for a meat sample submitted to a 0.2 strain, myofibrillar structure developed a maximum stress which was about 35 N/cm(2) when measurements were done near rigor mortis. This value decreased to about 4 N/cm(2) when meat was aged. Theses values of stresses were slightly lower than those obtained with sinusoidal compression. The two methods were as suitable for measurement of meat ageing. Nevertheless they did not give exactly the same stresses values because samples were not tested with the same strain history in both method and meat has a slight speed-dependent mechanical behaviour.
引用
收藏
页码:1234 / &
相关论文
共 50 条
  • [21] Measurement of Antioxidant Capacity of Meat and Meat Products: Methods and Applications
    Echegaray, Noemi
    Pateiro, Mirian
    Munekata, Paulo E. S.
    Lorenzo, Jose M.
    Chabani, Zakariya
    Farag, Mohamed A.
    Dominguez, Ruben
    MOLECULES, 2021, 26 (13):
  • [22] COMPARISON OF MECHANICAL COUPLING FACTOR BY 2 METHODS
    KHABBAZ, GR
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1970, 47 (1P2): : 392 - &
  • [23] A COMPARISON OF 2 METHODS OF MEASUREMENT OF THE SILENT PERIOD
    HANLEY, MR
    RUGH, JD
    DALE, RA
    HICKS, JL
    JOURNAL OF DENTAL RESEARCH, 1984, 63 : 194 - 194
  • [24] STATISTICAL COMPARISON OF 2 METHODS OF CLINICAL MEASUREMENT
    KMIOT, WA
    BRITISH JOURNAL OF SURGERY, 1990, 77 (04) : 384 - 385
  • [25] A COMPARISON OF 2 METHODS FOR MEASUREMENT OF ATMOSPHERIC NITRATES
    WIEBE, A
    ANLAUF, K
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1986, 192 : 114 - ENVR
  • [26] COMPARISON OF 2 DIFFERENT METHODS OF OTF MEASUREMENT
    YEADON, EC
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1969, 59 (04) : 501 - &
  • [27] A COMPARISON OF 2 DIFFERENT METHODS OF OTF MEASUREMENT
    YEADON, EC
    APPLIED OPTICS, 1969, 8 (12): : 2541 - &
  • [28] DISPLAY METHODS FOR VISUAL COMPARISON OF THE RESULTS OF 2 MEASUREMENT METHODS
    HARTMANN, C
    MASSART, DL
    JOURNAL OF AOAC INTERNATIONAL, 1994, 77 (05) : 1318 - 1325
  • [29] A COMPARISON OF DIFFERENT MEASUREMENT METHODS OF MECHANICAL PROPERTIES OF Al THIN FILMS
    Truhlar, Michal
    Bursikova, Vilma
    Sobota, Jaroslav
    Kruml, Tomas
    NANOCON 2014, 6TH INTERNATIONAL CONFERENCE, 2015, : 753 - 758
  • [30] NONDESTRUCTIVE EVALUATION FOR CORROSION IN AGING AIRCRAFT .2. RADIOGRAPHY, MECHANICAL IMPEDANCE AND ALTERNATIVE METHODS - COMPARISON OF TECHNIQUES
    SMITH, RA
    INSIGHT, 1995, 37 (11): : 884 - 891