ABSOLUTE SENSITIVITY OF X-RAY IMAGE CONVERTER IN THE RANGE OF 7-20 KEV

被引:0
|
作者
DOLBNYA, IP [1 ]
KNYAZEV, BA [1 ]
SIMONOV, VP [1 ]
FELDMAN, GG [1 ]
机构
[1] ALL UNION OPT PHYS MEASUREMENT RES INST,MOSCOW,USSR
关键词
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The authors measure the absolute spectral sensitivity of an x-ray image converter (XIC) with a beryllium window and a microchannel plate as a converting and amplifying element in the energy range of x-ray quanta of 7 to 20 keV. The measurements are performed in the synchrotron-radiation channel of the VEPP-3M accumulator of the Institute of Nuclear Physics of the Siberian Division of the Academy of Sciences of the USSR. It is shown that in the indicated energy range the ratio of the number of photons in the blue region of the spectrum at the exit from the XIC to the number of x-ray quanta at the entrance increases from 1200 to 2200 photons per quantum. The sensitivity variation over the working field of the XIC is studied.
引用
收藏
页码:950 / 952
页数:3
相关论文
共 50 条
  • [31] A portable Compton spectrometer for clinical X-ray beams in the energy range 20-150 keV
    Vieira, A. A.
    Linke, A.
    Yoshimura, E. M.
    Terini, R. A.
    Herdade, S. B.
    APPLIED RADIATION AND ISOTOPES, 2011, 69 (02) : 350 - 357
  • [32] BALLOON OBSERVATION OF X-RAY SOURCES IN CYGNUS REGION IN ENERGY RANGE 20-130 KEV
    BLEEKER, JAM
    BURGER, JJ
    DEERENBE.AJ
    SCHEEPMA.A
    SWANENBU.BN
    TANAKA, Y
    ASTROPHYSICAL JOURNAL, 1967, 147 (01): : 391 - &
  • [33] SOLEX:: a tunable monochromatic X-ray source in the 1-20 keV energy range for metrology
    Bonnelle, C
    Jonnard, P
    André, JM
    Avila, A
    Laporte, D
    Ringuenet, H
    Lépy, MC
    Plagnard, J
    Ferreux, L
    Protas, JC
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 516 (2-3): : 594 - 601
  • [34] X-RAY SUVEY OF NORTHERN SKY OBSERVATION OF SPECTRA IN ENERGY RANGE FROM 20 TO 100 KEV
    LEWIN, WHG
    CLARK, GW
    SMITH, WB
    ASTRONOMICAL JOURNAL, 1967, 72 (07): : 812 - &
  • [35] Efficiency calibrations of cylindrically bent transmission crystals in the 20 to 80 keV x-ray energy range
    Szabo, Csilla I.
    Feldman, Uri
    Seltzer, Stephen
    Hudson, Lawrence T.
    O'Brien, Michelle
    Park, Hye-Sook
    Seely, John F.
    OPTICS LETTERS, 2011, 36 (08) : 1335 - 1337
  • [36] Numerical simulation of X-ray image converter tube
    Chen T.
    Hu X.
    Liu S.
    Qiangjiguang Yu Lizishu/High Power Laser and Particle Beams, 2010, 22 (11): : 2593 - 2595
  • [37] Absolute measurements of x-ray backlighter sources at energies above 10 keV
    Maddox, B. R.
    Park, H. S.
    Remington, B. A.
    Chen, C.
    Chen, S.
    Prisbrey, S. T.
    Comley, A.
    Back, C. A.
    Szabo, C.
    Seely, J. F.
    Feldman, U.
    Hudson, L. T.
    Seltzer, S.
    Haugh, M. J.
    Ali, Z.
    PHYSICS OF PLASMAS, 2011, 18 (05)
  • [38] X-ray spectroscopy and calibrations in the 50 eV to 60 keV range
    Seely, JF
    Hudson, LT
    Weaver, JL
    Holland, GE
    Boyer, CN
    PENETRATING RADIATION SYSTEMS AND APPLICATIONS IV, 2002, 4786 : 183 - 188
  • [39] Instrumental aspects of x-ray microbeams in the range above 1 keV
    Dhez, P
    Chevallier, P
    Lucatorto, TB
    Tarrio, C
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (04): : 1907 - 1920
  • [40] X-ray spectroscopy and calibrations in the 50 eV to 60 keV range
    Seely, J
    Feldman, U
    Weaver, J
    Hudson, L
    ADVANCED DIAGNOSTICS FOR MAGNETIC AND INERTIAL FUSION, 2002, : 245 - 248