ABSOLUTE SENSITIVITY OF X-RAY IMAGE CONVERTER IN THE RANGE OF 7-20 KEV

被引:0
|
作者
DOLBNYA, IP [1 ]
KNYAZEV, BA [1 ]
SIMONOV, VP [1 ]
FELDMAN, GG [1 ]
机构
[1] ALL UNION OPT PHYS MEASUREMENT RES INST,MOSCOW,USSR
关键词
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The authors measure the absolute spectral sensitivity of an x-ray image converter (XIC) with a beryllium window and a microchannel plate as a converting and amplifying element in the energy range of x-ray quanta of 7 to 20 keV. The measurements are performed in the synchrotron-radiation channel of the VEPP-3M accumulator of the Institute of Nuclear Physics of the Siberian Division of the Academy of Sciences of the USSR. It is shown that in the indicated energy range the ratio of the number of photons in the blue region of the spectrum at the exit from the XIC to the number of x-ray quanta at the entrance increases from 1200 to 2200 photons per quantum. The sensitivity variation over the working field of the XIC is studied.
引用
收藏
页码:950 / 952
页数:3
相关论文
共 50 条
  • [21] Measurement of absolute x-ray intensities and absolute sensitivity of x-ray film with a Geiger-Muller counter
    Locher, GL
    LeGalley, DP
    PHYSICAL REVIEW, 1934, 46 (12): : 1047 - 1051
  • [22] X-RAY FLUX FROM CENTAURUS X-2 IN ENERGY RANGE 2-20-KEV
    RAO, UR
    CHITNIS, EV
    PRAKASAR.AS
    JAYANTHI, UB
    ASTROPHYSICAL JOURNAL, 1969, 157 (2P2): : L127 - &
  • [23] HARD X-RAY-DETECTOR WITH AN MCP IMAGE INTENSIFIER WORKING IN THE 100 KEV 1 MEV X-RAY RANGE
    VEAUX, J
    CAVAILLER, C
    GEX, JP
    HAUDUCOEUR, A
    HYVERNAGE, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1991, 62 (06): : 1562 - 1567
  • [24] A Medium-Range-Energy X-Ray Source Based on an Image Converter Tube
    Andreev, S., V
    Vorobiev, N. S.
    Mikhal'kov, Yu M.
    Smirnov, A., V
    Shashkov, E., V
    Tur'yanskii, A. G.
    Senkov, V. M.
    Pirshin, I., V
    Fishman, R., I
    Giga, S. S.
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2021, 64 (02) : 264 - 269
  • [25] A Medium-Range-Energy X-Ray Source Based on an Image Converter Tube
    S. V. Andreev
    N. S. Vorobiev
    Yu. M. Mikhal’kov
    A. V. Smirnov
    E. V. Shashkov
    A. G. Tur’yanskii
    V. M. Senkov
    I. V. Pirshin
    R. I. Fishman
    S. S. Giga
    Instruments and Experimental Techniques, 2021, 64 : 264 - 269
  • [26] Absolute responsivity of silicon photodiodes in the x-ray range
    Krumrey, M
    Büermann, L
    Hoffmann, M
    Müller, P
    Scholze, F
    Ulm, G
    SYNCHROTRON RADIATION INSTRUMENTATION, 2004, 705 : 861 - 864
  • [27] Monochromatic focusing of subpicosecond x-ray pulses in the keV range
    Missalla, T
    Uschmann, I
    Förster, E
    Jenke, G
    von der Linde, D
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (02): : 1288 - 1299
  • [28] X-RAY SPECTROMETER IN RANGE 5-200 KEV
    STRACHAN, JD
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1976, 21 (05): : 852 - 852
  • [29] Sensitivity degradation of X-ray diodes in 2 to 6 keV
    Wu G.
    Wu J.
    Qiu A.
    Wang L.
    Lü M.
    Qiu M.
    Cong P.
    Zheng L.
    Cui M.
    Zhao Y.
    Qiangjiguang Yu Lizishu/High Power Laser and Particle Beams, 2010, 22 (06): : 1285 - 1290
  • [30] 2-20-KEV X-RAY SKY BACKGROUND
    BOLDT, EA
    DESAI, UD
    HOLT, SS
    SERLEMITSOS, PJ
    NATURE, 1969, 224 (5220) : 677 - +