Comparison of standard mammography with digital mammography and digital infrared thermal imaging for breast cancer screening

被引:26
|
作者
Kosus, Nermin [1 ]
Kosus, Aydin [1 ]
Duran, Muzeyyen [1 ]
Simavli, Serap [1 ]
Turhan, Nilgun [1 ]
机构
[1] Fatih Univ, Fac Med, Dept Obstet & Gynecol, Ankara, Turkey
关键词
Mammography; digital mammography; digital infrared thermal imaging; breast cancer;
D O I
10.5152/jtgga.2010.24
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Breast cancer is the most common malignancy in women. Screen-film mammography (SFM) has been considered the gold standard for breast cancer screening and detection. Despite its recognized value in detecting and characterizing breast disease, mammography has important limitations and its false-negative rate ranges from 4% to 34%. Given these limitations, development of imaging modalities that would enhance, complement, or replace mammography has been a priority. Digital mammography (FFDM) and digital infrared thermal imaging (DITI) are some of these alternative modalities.
引用
收藏
页码:152 / 157
页数:6
相关论文
共 50 条
  • [41] Comparison of Breast Density Between Synthesized Versus Standard Digital Mammography
    Haider, Irfanullah
    Morgan, Matthew
    McGow, Anna
    Stein, Matthew
    Rezvani, Maryam
    Freer, Phoebe
    Hu, Nan
    Fajardo, Laurie
    Winkler, Nicole
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2018, 15 (10) : 1430 - 1436
  • [42] Screening Mammography and Digital Breast Tomosynthesis: Controversies
    Funaro, Kimberly
    Drukteinis, Jennifer
    Falcon, Shannon
    SOUTHERN MEDICAL JOURNAL, 2017, 110 (10) : 607 - 613
  • [43] Breast Cancer Screening Using Mammography, Digital Breast Tomosynthesis, and Magnetic Resonance Imaging by Breast Density
    Stout, Natasha K.
    Miglioretti, Diana L.
    Su, Yu-Ru
    Lee, Christoph I.
    Abraham, Linn
    Alagoz, Oguzhan
    de Koning, Harry J.
    Hampton, John M.
    Henderson, Louise
    Lowry, Kathryn P.
    Mandelblatt, Jeanne S.
    Onega, Tracy
    Schechter, Clyde B.
    Sprague, Brian L.
    Stein, Sarah
    Trentham-Dietz, Amy
    van Ravesteyn, Nicolien T.
    Wernli, Karen J.
    Kerlikowske, Karla
    Tosteson, Anna N. A.
    JAMA INTERNAL MEDICINE, 2024, 184 (10) : 1222 - 1231
  • [44] Comparison of the clinical performance of three digital mammography systems in a breast cancer screening programme
    Keavey, E.
    Phelan, N.
    O'Connell, A. M.
    Flanagan, F.
    O'Doherty, A.
    Larke, A.
    Connors, A. M.
    BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1016): : 1123 - 1127
  • [45] The TOMMY trial: a comparison of TOMosynthesis with digital MammographY in the UK NHS Breast Screening Programme a multicentre retrospective reading study comparing the diagnostic performance of digital breast tomosynthesis and digital mammography with digital mammography alone
    Gilbert, Fiona J.
    Tucker, Lorraine
    Gillan, Maureen G. C.
    Willsher, Paula
    Cooke, Julie
    Duncan, Karen A.
    Michell, Michael J.
    Dobson, Hilary M.
    Lim, Yit Yoong
    Purushothaman, Hema
    Strudley, Celia
    Astley, Susan M.
    Morrish, Oliver
    Young, Kenneth C.
    Duffy, Stephen W.
    HEALTH TECHNOLOGY ASSESSMENT, 2015, 19 (04) : 1 - +
  • [46] Comparison of Acquisition Parameters and Breast Dose in Digital Mammography and Screen-Film Mammography in the American College of Radiology Imaging Network Digital Mammographic Imaging Screening Trial
    Hendrick, R. Edward
    Pisano, Etta D.
    Averbukh, Alice
    Moran, Catherine
    Berns, Eric A.
    Yaffe, Martin J.
    Herman, Benjamin
    Acharyya, Suddhasatta
    Gatsonis, Constantine
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (02) : 362 - 369
  • [47] Screening Mammography Findings From One Standard Projection Only in the Era of Full-Field Digital Mammography and Digital Breast Tomosynthesis
    Cohen, Ethan O.
    Tso, Hilda H.
    Phalak, Kanchan A.
    Mayo, Ray C.
    Leung, Jessica W. T.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 211 (02) : 445 - 451
  • [48] Double reading of automated breast ultrasound with digital mammography or digital breast tomosynthesis for breast cancer screening
    Lee, Janie M.
    Partridge, Savannah C.
    Liao, Geraldine J.
    Hippe, Daniel S.
    Kim, Adrienne E.
    Lee, Christoph, I
    Rahbar, Habib
    Scheel, John R.
    Lehman, Constance D.
    CLINICAL IMAGING, 2019, 55 : 119 - 125
  • [49] Accuracy in tumor size measurements: Comparison of digital mammography, digital breast tomosynthesis and synthetic mammography
    Sendur, Halit Nahit
    Cerit, Mahi Nur
    Gultekin, Serap
    Cindil, Emetullah
    Aslan, Aydan Avdan
    Erdal, Zeynep Sezgi
    Gultekin, Isil Imge
    Teke, Furkan
    CLINICAL IMAGING, 2021, 69 : 115 - 119
  • [50] Addition of Screening Breast US to Digital Mammography and Digital Breast Tomosynthesis for Breast Cancer Screening in Women at Average Risk
    Yi, Ann
    Jang, Myoung-jin
    Yim, Dahae
    Kwon, Bo Ra
    Shin, Sung Ui
    Chang, Jung Min
    RADIOLOGY, 2021, 298 (03) : 568 - 575