Accuracy in tumor size measurements: Comparison of digital mammography, digital breast tomosynthesis and synthetic mammography

被引:2
|
作者
Sendur, Halit Nahit [1 ]
Cerit, Mahi Nur [1 ]
Gultekin, Serap [1 ]
Cindil, Emetullah [1 ]
Aslan, Aydan Avdan [1 ]
Erdal, Zeynep Sezgi [1 ]
Gultekin, Isil Imge [1 ]
Teke, Furkan [1 ]
机构
[1] Gazi Univ, Fac Med, Dept Radiol, Mevlana Bulvari 29, TR-06560 Ankara, Turkey
关键词
Digital mammography; Digital breast tomosynthesis; Synthetic mammography; Tumor size; Accuracy; DIAGNOSTIC-ACCURACY; PREOPERATIVE ASSESSMENT; SONOGRAPHY; PREDICTION; DENSITY; MRI;
D O I
10.1016/j.clinimag.2020.07.004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The aim of this study was to assess the accuracy of digital mammography (DM), digital breast tomosynthesis (DBT) and synthetic mammography (SM) in tumor size measurements compared with histological tumor sizes. Materials and methods: 71 breast cancer patients who underwent DM and DBT acquisitions simultaneously were included in this study. One radiologist with 8 years of experience in breast imaging measured tumor sizes independently in three separate sessions which include DM, DBT and SM images, respectively. The correlations between the measured tumor sizes on each imaging technique and histological sizes were analyzed using Spearman correlation test. The patients were categorized into two subgroups according to assigned breast density categories (dense and non-dense), and histological tumor sizes (<= 2 cm and > 2 cm). To assess the agreement levels between the measured tumor sizes and histological sizes Bland-Altman analyses were performed for each imaging technique. Results: The mean of histological size of tumors was 23.85 16.57 mm (median: 20). The means of measured tumor sizes were 21.21 +/- 13.59 mm (median: 19), 21.52 +/- 13.42 mm (median: 19) and 18.97 +/- 11.21 mm (median: 17) in DM, DBT and SM, respectively. The Spearman correlation values with histologic sizes were 0.814 (P < 0.001), 0.887 (P < 0.001), and 0.852 (P < 0.001) for DM, DBT and SM, respectively. In subgroup analyses, the correlation values showed decrement for tumors 2 cm in size compared to tumors <= 2 cm in size. Conclusion: DBT provides the most accurate tumor size measurements among mammographic imaging techniques and if mammography will be used in tumor size measurements, DBT should be preferred.
引用
收藏
页码:115 / 119
页数:5
相关论文
共 50 条
  • [1] Breast tomosynthesis and digital mammography: a comparison of diagnostic accuracy
    Svahn, T. M.
    Chakraborty, D. P.
    Ikeda, D.
    Zackrisson, S.
    Do, Y.
    Mattsson, S.
    Andersson, I.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1019): : E1074 - E1082
  • [2] Microcalcifications Detected at Screening Mammography: Synthetic Mammography and Digital Breast Tomosynthesis versus Digital Mammography
    Lai, Yi-Chen
    Ray, Kimberly M.
    Lee, Amie Y.
    Hayward, Jessica H.
    Freimanis, Rita I.
    Lobach, Iryna V.
    Joe, Bonnie N.
    [J]. RADIOLOGY, 2018, 289 (03) : 630 - 638
  • [3] Breast Cancer Screening via Digital Mammography, Synthetic Mammography, and Tomosynthesis
    Cohen, Ethan O.
    Weaver, Olena O.
    Tso, Hilda H.
    Gerlach, Karen E.
    Leung, Jessica W. T.
    [J]. AMERICAN JOURNAL OF PREVENTIVE MEDICINE, 2020, 58 (03) : 470 - 472
  • [4] Digital Mammography and Digital Breast Tomosynthesis
    Moseley, Tanya W.
    [J]. CLINICAL OBSTETRICS AND GYNECOLOGY, 2016, 59 (02): : 362 - 379
  • [5] A comparison of the accuracy of film-screen mammography, full-field digital mammography, and digital breast tomosynthesis
    Michell, M. J.
    Iqbal, A.
    Wasan, R. K.
    Evans, D. R.
    Peacock, C.
    Lawinski, C. P.
    Douiri, A.
    Wilson, R.
    Whelehan, P.
    [J]. CLINICAL RADIOLOGY, 2012, 67 (10) : 976 - 981
  • [6] Breast tomosynthesis: Accuracy of tumor measurement compared with digital mammography and ultrasonography
    Fornvik, Daniel
    Zackrisson, Sophia
    Ljungberg, Otto
    Svahn, Tony
    Timberg, Pontus
    Tingberg, Anders
    Andersson, Ingvar
    [J]. ACTA RADIOLOGICA, 2010, 51 (03) : 240 - 247
  • [7] Comparison of Tomosynthesis Plus Digital Mammography and Digital Mammography Alone for Breast Cancer Screening
    Haas, Brian M.
    Kalra, Vivek
    Geisel, Jaime
    Raghu, Madhavi
    Durand, Melissa
    Philpotts, Liane E.
    [J]. RADIOLOGY, 2013, 269 (03) : 694 - 700
  • [8] Comparison of synthetic and digital mammography with digital breast tomosynthesis or alone for the detection and classification of microcalcifications
    Choi, Ji Soo
    Han, Boo-Kyung
    Ko, Eun Young
    Kim, Ga Ram
    Ko, Eun Sook
    Park, Ko Woon
    [J]. EUROPEAN RADIOLOGY, 2019, 29 (01) : 319 - 329
  • [9] Comparison of synthetic and digital mammography with digital breast tomosynthesis or alone for the detection and classification of microcalcifications
    Ji Soo Choi
    Boo-Kyung Han
    Eun Young Ko
    Ga Ram Kim
    Eun Sook Ko
    Ko Woon Park
    [J]. European Radiology, 2019, 29 : 319 - 329
  • [10] Advancing synthetic mammography for stationary digital breast tomosynthesis
    Puett, Connor
    Inscoe, Christina
    Lu, Jianping
    Lee, Yueh
    Zhou, Otto
    [J]. MEDICAL IMAGING 2020: PHYSICS OF MEDICAL IMAGING, 2020, 11312