ATRAUMATIC QUANTITATION OF CEREBRAL PERFUSION IN CATS BY F-19 MAGNETIC-RESONANCE-IMAGING

被引:9
|
作者
BRANCH, CA
EWING, JR
HELPERN, JA
ORDIDGE, RJ
BUTT, S
WELCH, KMA
机构
[1] Center for Stroke Research, Department of Neurology, Henry Ford Hospital, Detroit, Michigan
关键词
D O I
10.1002/mrm.1910280105
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We have noninvasively produced low‐resolution, quantitative nuclear magnetic resonance images of cerebral blood flow in 2‐ml voxels in eight cats. Typical signal‐to‐noise of 4 to 1 was obtained in cerebral voxels in 16.5‐s epochs. Mean flow during normocapnia (paCO2 = 39 ± 4 mm Hg) and hypercapnia (paCO2 = 62 ± 4 mm Hg) was 53 ± 20 ml/100 gmin and 140 ± 36 ml/100 g‐min, respectively. Fast flows in normocapnia were 94 ± 13 and 182 ± 39 ml/100 g‐min in hypercapnia. These results suggest that an atraumatic quantitative imaging assessment of cerebral perfusion may be possible in humans using these techniques.© 1992 Academic Press,Inc. Copyright © 1992 Wiley‐Liss, Inc., A Wiley Company
引用
收藏
页码:39 / 53
页数:15
相关论文
共 50 条
  • [1] DETECTION OF TUMORS WITH F-19 MAGNETIC-RESONANCE-IMAGING
    RATNER, AV
    MULLER, HH
    SIMPSON, BB
    JOHNSON, DE
    HURD, R
    YOUNG, SW
    INVESTIGATIVE RADIOLOGY, 1987, 22 (09) : S10 - S10
  • [2] PROTEIN MICROSPHERES FOR F-19 MAGNETIC-RESONANCE-IMAGING (MRI)
    WONG, M
    KOLBECK, KJ
    WILMES, LJ
    MAGIN, RL
    WEBB, AG
    SUSLICK, KS
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1993, 206 : 6 - FLUO
  • [3] PERFUSION DIFFUSION QUANTITATION WITH MAGNETIC-RESONANCE-IMAGING
    PICKENS, DR
    INVESTIGATIVE RADIOLOGY, 1992, 27 : S12 - S17
  • [4] USE OF F-19 MAGNETIC-RESONANCE-IMAGING TO MEASURE LOCAL CEREBRAL BLOOD-VOLUME
    LU, DF
    JOSEPH, PM
    GREENBERG, JH
    LIN, R
    MUKHERJI, B
    SLOVITER, HA
    MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (02) : 179 - 187
  • [5] A NEW PERFLUOROCARBON FOR USE IN F-19 MAGNETIC-RESONANCE-IMAGING AND SPECTROSCOPY
    SOTAK, CH
    HEES, PS
    HUANG, HN
    HUNG, MH
    KRESPAN, CG
    RAYNOLDS, S
    MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (02) : 188 - 195
  • [6] EXPERIMENTAL APPROACH TO USING EXTRINSIC F-19 IN MAGNETIC-RESONANCE-IMAGING
    YOSHIKAWA, K
    YAMADA, S
    SHIONO, T
    ITOH, M
    IRIGUCHI, N
    TAKIZAWA, O
    IIO, M
    INVESTIGATIVE RADIOLOGY, 1990, 25 : S46 - S47
  • [7] F-19 MAGNETIC-RESONANCE-IMAGING OF CEREBRAL BLOOD-FLOW WITH 0.4-CC RESOLUTION
    PEKAR, J
    LIGETI, L
    SINNWELL, T
    MOONEN, CTW
    FRANK, JA
    MCLAUGHLIN, AC
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1994, 14 (04): : 656 - 663
  • [8] FLUORINATED PROTEINS AS NEW F-19 MAGNETIC-RESONANCE-IMAGING AND SPECTROSCOPY AGENTS
    MEHTA, VD
    KULKARNI, PV
    MASON, RP
    CONSTANTINESCU, A
    ANTICH, PP
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1992, 204 : 166 - MEDI
  • [9] FLUORINATED PROTEINS AS POTENTIAL F-19 MAGNETIC-RESONANCE-IMAGING AND SPECTROSCOPY AGENTS
    MEHTA, VD
    KULKARNI, PV
    MASON, RP
    CONSTANTINESCU, A
    ANTICH, PP
    BIOCONJUGATE CHEMISTRY, 1994, 5 (03) : 257 - 261
  • [10] PARAMETER OPTIMIZATION AND CALIBRATION OF F-19 MAGNETIC-RESONANCE-IMAGING AT 1.5 TESLA
    GONG, B
    GILL, M
    WASHBURN, DB
    DAVENPORT, WC
    ADAMS, D
    KWOCK, L
    MAGNETIC RESONANCE IMAGING, 1991, 9 (01) : 101 - 106