PARAMETER OPTIMIZATION AND CALIBRATION OF F-19 MAGNETIC-RESONANCE-IMAGING AT 1.5 TESLA

被引:12
|
作者
GONG, B [1 ]
GILL, M [1 ]
WASHBURN, DB [1 ]
DAVENPORT, WC [1 ]
ADAMS, D [1 ]
KWOCK, L [1 ]
机构
[1] UNIV N CAROLINA,CTR MAGNET RESONANCE IMAGING,DEPT RADIOL,CB 7515 MED RES BLDG D,CHAPEL HILL,NC 27599
关键词
F-19; MRI; GADOLINIUM; FAST-FIELD ECHO;
D O I
10.1016/0730-725X(91)90103-S
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Fluorine-19 magnetic resonance imaging is limited by the fact that acquisition times are long and that high concentrations must be used in order to obtain good signal to noise. A significant improvement in signal to noise ratio may be brought about by the addition of Gd-DTPA, a paramagnetic agent which shortens T1. Images of phantoms containing trifluoroacetic acid (TFA) doped with Gd-DTPA were obtained using a standard spin echo sequence in a 1.5 T field. Interpulse times (TR and TE) and Gd-DTPA concentrations were optimized to yield maximum signal to noise ratios. The use of fast-field-echo scans to image fluorine is also demonstrated. Signal averaging successive FFE scans yields good signal to noise and resolution and may find clinical applicability in imaging areas subject to motion.
引用
收藏
页码:101 / 106
页数:6
相关论文
共 50 条
  • [1] DETECTION OF TUMORS WITH F-19 MAGNETIC-RESONANCE-IMAGING
    RATNER, AV
    MULLER, HH
    SIMPSON, BB
    JOHNSON, DE
    HURD, R
    YOUNG, SW
    INVESTIGATIVE RADIOLOGY, 1987, 22 (09) : S10 - S10
  • [2] PROTEIN MICROSPHERES FOR F-19 MAGNETIC-RESONANCE-IMAGING (MRI)
    WONG, M
    KOLBECK, KJ
    WILMES, LJ
    MAGIN, RL
    WEBB, AG
    SUSLICK, KS
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1993, 206 : 6 - FLUO
  • [3] A NEW PERFLUOROCARBON FOR USE IN F-19 MAGNETIC-RESONANCE-IMAGING AND SPECTROSCOPY
    SOTAK, CH
    HEES, PS
    HUANG, HN
    HUNG, MH
    KRESPAN, CG
    RAYNOLDS, S
    MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (02) : 188 - 195
  • [4] EXPERIMENTAL APPROACH TO USING EXTRINSIC F-19 IN MAGNETIC-RESONANCE-IMAGING
    YOSHIKAWA, K
    YAMADA, S
    SHIONO, T
    ITOH, M
    IRIGUCHI, N
    TAKIZAWA, O
    IIO, M
    INVESTIGATIVE RADIOLOGY, 1990, 25 : S46 - S47
  • [5] TECHNICAL ASPECTS ON MAGNETIC-RESONANCE-IMAGING OF THE SPINE AT 1.5 TESLA
    HOLTAS, SL
    PLEWES, DB
    SIMON, JH
    EKHOLM, S
    KIDO, DK
    UTZ, R
    ACTA RADIOLOGICA, 1987, 28 (04) : 375 - 381
  • [6] FLUORINATED PROTEINS AS NEW F-19 MAGNETIC-RESONANCE-IMAGING AND SPECTROSCOPY AGENTS
    MEHTA, VD
    KULKARNI, PV
    MASON, RP
    CONSTANTINESCU, A
    ANTICH, PP
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1992, 204 : 166 - MEDI
  • [7] FLUORINATED PROTEINS AS POTENTIAL F-19 MAGNETIC-RESONANCE-IMAGING AND SPECTROSCOPY AGENTS
    MEHTA, VD
    KULKARNI, PV
    MASON, RP
    CONSTANTINESCU, A
    ANTICH, PP
    BIOCONJUGATE CHEMISTRY, 1994, 5 (03) : 257 - 261
  • [8] ATRAUMATIC QUANTITATION OF CEREBRAL PERFUSION IN CATS BY F-19 MAGNETIC-RESONANCE-IMAGING
    BRANCH, CA
    EWING, JR
    HELPERN, JA
    ORDIDGE, RJ
    BUTT, S
    WELCH, KMA
    MAGNETIC RESONANCE IN MEDICINE, 1992, 28 (01) : 39 - 53
  • [9] MAGNETIC-RESONANCE-IMAGING (1.5 TESLA) IN PATIENTS WITH INTRACTABLE FOCAL SEIZURES
    LESSER, RP
    MODIC, MT
    WEINSTEIN, MA
    DUCHESNEAU, PM
    LUDERS, H
    DINNER, DS
    MORRIS, HH
    ESTES, M
    CHOU, SM
    HAHN, JF
    ARCHIVES OF NEUROLOGY, 1986, 43 (04) : 367 - 371
  • [10] FIBROUS DYSPLASIA - MAGNETIC-RESONANCE-IMAGING APPEARANCE AT 1.5-TESLA
    NORRIS, MA
    KAPLAN, PA
    PATHRIA, M
    GREENWAY, G
    CLINICAL IMAGING, 1990, 14 (03) : 211 - 215