Measurement of the thermal conductivity of argon using hot-wire type thermal diffusion columns

被引:31
|
作者
Saxena, V. K. [1 ]
Saxena, S. C.
机构
[1] Univ Rajasthan, Dept Phys, Jaipur 302004, Rajasthan, India
[2] Purdue Univ, Thermophys Properties Res Ctr, Lafayette, IN USA
[3] Univ Saugar, Dept Pharm, Sagar, India
关键词
D O I
10.1016/0009-2614(68)80144-7
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Hot wire type of thermal diffusion columns have been used to determine thermal conductivity of argon. Convection. temperature jump and end conduction are established experimentally to be small. The new data taken in the range 350 to 1500 degrees K are correlated by 10(5)lambda = 1.355 + 1.091 x 10(-2)T - 1.876 x 10(-6)T(2). Here the thermal conductivity, lambda is in cal cm(-1) sec(-1) deg(-1) and temperature, T. in degrees K. It is found that the new X values agree with all the existing data and theory well within the estimated total uncertainty of +/- 2% of our measurement.
引用
收藏
页码:44 / 46
页数:3
相关论文
共 50 条
  • [21] MEASUREMENT OF THE THERMAL-CONDUCTIVITY OF GASES BY THE TRANSIENT HOT-WIRE METHOD
    JOHNS, AI
    SCOTT, AC
    WATSON, JTR
    FERGUSON, D
    CLIFFORD, AA
    [J]. PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 1988, 325 (1585): : 295 - 356
  • [22] PERFORMANCE OF A HOT-WIRE THERMAL DIFFUSION COLUMN
    CORBETT, JW
    WATSON, WW
    [J]. PHYSICAL REVIEW, 1956, 101 (02): : 519 - 522
  • [23] Further examination of the transient hot-wire method for the simultaneous measurement of thermal conductivity and thermal diffusivity
    Watanabe, H
    [J]. METROLOGIA, 2002, 39 (01) : 65 - 81
  • [24] Further elucidation of nanofluid thermal conductivity measurement using a transient hot-wire method apparatus
    Yoo, Donghoon
    Lee, Joohyun
    Lee, Byeongchan
    Kwon, Suyong
    Koo, Junemo
    [J]. HEAT AND MASS TRANSFER, 2018, 54 (02) : 415 - 424
  • [25] Thermal conductivity measurements using the transient hot-wire method: a review
    Salim, S. G. R.
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2022, 33 (12)
  • [26] Inverse method applied to the measurement of the thermal conductivity of powders by a Hot-Wire technique
    Remy, B.
    Degiovanni, A.
    [J]. Thermal Conductivity 26: Thermal Expansion 14, 2005, 26 : 334 - 345
  • [27] Further elucidation of nanofluid thermal conductivity measurement using a transient hot-wire method apparatus
    Donghoon Yoo
    Joohyun Lee
    Byeongchan Lee
    Suyong Kwon
    Junemo Koo
    [J]. Heat and Mass Transfer, 2018, 54 : 415 - 424
  • [28] A hot-wire method based thermal conductivity measurement apparatus for teaching purposes
    Alvarado, S.
    Marin, E.
    Juarez, A. G.
    Calderon, A.
    Ivanov, R.
    [J]. EUROPEAN JOURNAL OF PHYSICS, 2012, 33 (04) : 897 - 906
  • [29] RAPID MEASUREMENT OF LIQUID THERMAL-CONDUCTIVITY BY TRANSIENT HOT-WIRE METHOD
    TRUMP, WN
    LUEBKE, HW
    FOWLER, L
    EMERY, EM
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1977, 48 (01): : 47 - 51
  • [30] Thermal Conductivity Measurement of Semitransparent Solids by Hot-Wire Technique1
    F. Yu
    X. Zhang
    G. Gao
    [J]. International Journal of Thermophysics, 2000, 21 : 465 - 478