HOT-ELECTRON MICROCALORIMETERS FOR X-RAY AND PHONON DETECTION

被引:26
|
作者
NAHUM, M [1 ]
MARTINIS, JM [1 ]
CASTLES, S [1 ]
机构
[1] NASA,GODDARD SPACE FLIGHT CTR,GREENBELT,MD 20771
关键词
D O I
10.1007/BF00693504
中图分类号
O59 [应用物理学];
学科分类号
摘要
We propose a novel hot-electron microcalorimeter for measurements of x-rays or phonons produced by the interaction of a high energy particle with the underlying substrate. This type of detector uses a normal metal film to absorb the incoming excitation which subsequently heats the electrons above the lattice temperature. The temperature of the electrons is measured from the current - voltage characteristics of a superconductor-insulator-normal metal tunnel junction, where part of the absorber forms the normal electrode. We present simple calculations of the energy sensitivity of the junction and of the ultimate performance of x-ray and phonon detectors. We also present preliminary measurements of prototype devices which were used to test the basic detector physics.
引用
收藏
页码:733 / 738
页数:6
相关论文
共 50 条
  • [31] Large area bismuth absorbers for X-ray microcalorimeters
    Vaillancourt, JE
    Allen, CA
    Brekosky, R
    Dosaj, A
    Galeazzi, M
    Kelley, R
    Liu, D
    McCammon, D
    Porter, FS
    Rocks, LE
    Sanders, WT
    Stahle, CK
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 520 (1-3): : 212 - 215
  • [32] Code-division multiplexing for x-ray microcalorimeters
    Stiehl, G. M.
    Doriese, W. B.
    Fowler, J. W.
    Hilton, G. C.
    Irwin, K. D.
    Reintsema, C. D.
    Schmidt, D. R.
    Swetz, D. S.
    Ullom, J. N.
    Vale, L. R.
    APPLIED PHYSICS LETTERS, 2012, 100 (07)
  • [33] NONEQUILIBRIUM PHONON EFFECTS ON HOT-ELECTRON TRANSPORT IN SEMICONDUCTOR HETEROJUNCTIONS
    CAI, W
    MARCHETTI, MC
    LAX, M
    PHYSICAL REVIEW B, 1988, 37 (05): : 2636 - 2644
  • [34] Development of the multi-pixel x-ray microcalorimeters
    Kudo, H
    Nakamura, T
    Arakawa, T
    Ohtsuka, S
    Izumi, T
    Shoji, S
    Sato, H
    Kobayashi, H
    Mori, K
    Homma, T
    Osaka, T
    Mitsuda, K
    Yamasaki, NY
    Fujimoto, R
    Iyomoto, N
    Oshima, T
    Futamoto, K
    Takei, Y
    Ichitsubo, T
    Fujimori, T
    Ishisaki, Y
    Morita, U
    Koga, T
    Sato, K
    Ohashi, T
    Kuroda, Y
    Onishi, M
    Otake, K
    NANOTECH 2003, VOL 1, 2003, : 436 - 439
  • [35] Intermediate states of superconducting thermometers for x-ray microcalorimeters
    Pressler, H
    Koike, M
    Ohkubo, M
    Fukuda, D
    Noguchi, Y
    Ohno, M
    Takahashi, H
    Nakazawa, M
    APPLIED PHYSICS LETTERS, 2002, 81 (02) : 331 - 333
  • [36] Bismuth X-ray absorber studies for TES microcalorimeters
    Sadleir, JE
    Bandler, SR
    Brekosky, RP
    Chervenak, J
    Figueroa-Feliciano, E
    Finkbeiner, F
    Iyomoto, N
    Kelley, RL
    Kilbourne, CA
    King, JM
    Porter, FS
    Robinson, IK
    Saab, T
    Talley, DJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 559 (02): : 447 - 449
  • [37] TES x-ray microcalorimeters with single element superconductors
    Fukuda, D
    Noguchi, Y
    Ohno, M
    Takahashi, H
    Ataka, M
    Pressler, H
    Hirayama, F
    Ukibe, M
    Ohkubo, M
    Shimizu, HM
    Nakazawa, M
    LOW TEMPERATURE DETECTORS, 2002, 605 : 263 - 266
  • [38] Electron-phonon relaxation in hot-electron detectors below 1 K
    Karasik, BS
    Sergeev, AV
    Gershenson, ME
    LOW TEMPERATURE DETECTORS, 2002, 605 : 75 - 78
  • [39] EFFECTS OF COMBINED X-RAY-IRRADIATION AND HOT-ELECTRON INJECTION ON NMOS TRANSISTORS
    BALASINSKI, A
    CHEN, WL
    MA, TP
    JOURNAL OF ELECTRONIC MATERIALS, 1992, 21 (07) : 737 - 743
  • [40] Large Area Transition Edge Sensor X-ray Microcalorimeters for Diffuse X-ray Background Studies
    K. M. Morgan
    S. E. Busch
    M. E. Eckart
    C. A. Kilbourne
    D. McCammon
    Journal of Low Temperature Physics, 2014, 176 : 331 - 336