Haemodynamic response at double lumen bronchial tube placement Airtraq vs. MacIntosh laryngoscope, a randomised controlled trial

被引:0
|
作者
Hamp, Thomas [1 ]
Stumpner, Thomas [1 ]
Grubhofer, Georg [1 ]
Ruetzler, Kurt [1 ]
Thell, Rainer [1 ]
Hager, Helmut [1 ]
机构
[1] Med Univ Vienna, Dept Cardiothorac & Vasc Anaesthesia & Intens Car, Waehringer Guertel 18-20, A-1090 Vienna, Austria
关键词
stress response; intubation; double-lumen-tube; haemodynamics;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Tracheal intubation causes a haemodynamic response that might be harmful for patients. The Airtraq (R) laryngoscope has been shown to decrease the haemodynamic response to single-lumen tube intubation. We hypothesised that double-lumen bronchial tube placement with the Double-lumen Airtraq (R) laryngoscope would cause a reduced haemodynamic response and decreased catecholamine release compared with the MacIntosh laryngoscope. Methods: Forty adult patients were randomly assigned to the Airtraq (R) group or to the MacIntosh group. Intubation with either the Airtraq (R) or the MacIntosh laryngoscope was performed two minutes after standardised induction of anaesthesia. Arterial blood pressure, heart rate, catecholamine levels, bispectral index and duration of the intubation procedure were measured. Results: Mean (standard deviation [95% confidence interval]) systolic arterial blood pressure at laryngoscopy with the Airtraq (R) laryngoscope was 124 (34 [106 to 141]) mmHg and, with the MacIntosh laryngoscope, it was 110 (25 [99 to 122]) mmHg (p = 1.0). Heart rate at laryngoscopy with the Airtraq (R) laryngoscope was 75 beats min-1 (16 [67 to 83]) and, with the MacIntosh laryngoscope, it was 64 beats . min-1 (14 [58 to 71]) (p = 0.71). Adrenaline levels post-intubation were 54.3 ng . l-1 (41.5) [29.3 to 79.4] in the Airtraq r group and 30.5 ng . l-1 (25.6) [15.1 to 46.0] in the MacIntosh group (p = 0.016). The duration of intubation with the Airtraq r laryngoscope was 88 s (31 [72-104]) while, with the MacIntosh laryngoscope, the duration was 75 s (35 [59-92]) (p = 0.26). Conclusions: The use of the Double-lumen Airtraq (R) laryngoscope provides no benefit regarding stress response compared to the MacIntosh laryngoscope.
引用
收藏
页码:54 / 63
页数:10
相关论文
共 50 条
  • [1] Comparison of the Airtraq and the Macintosh laryngoscope for double-lumen tube intubation A randomised clinical trial
    Wasem, Simone
    Lazarus, Marc
    Hain, Johannes
    Festl, Jasmin
    Kranke, Peter
    Roewer, Norbert
    Lange, Markus
    Smul, Thorsten M.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2013, 30 (04) : 180 - 186
  • [2] Comparison of Airtraq DL™ and Macintosh laryngoscope for double-lumen tube placement in simulated difficult airway: A randomised study
    Mounika, K.
    Kar, Prachi
    Padhy, Shibani
    Pathy, Archana
    Durga, Padmaja
    INDIAN JOURNAL OF ANAESTHESIA, 2022, 66 (06) : 442 - 448
  • [3] The Airtraq® laryngoscope for placement of double-lumen endobronchial tube
    Hirabayashi, Yoshihiro
    Sco, Norimasa
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2007, 54 (11): : 955 - 957
  • [4] The Airtraq® laryngoscope for placement of double-lumen endobronchial tube
    Yoshihiro Hirabayashi
    Norimasa Seo
    Canadian Journal of Anesthesia, 2007, 54 : 955 - 957
  • [5] Use of the Macintosh laryngoscope for double-lumen tracheal tube placement
    Pieters, B. M. A.
    van Zundert, A. A. J.
    ANAESTHESIA, 2015, 70 (09) : 1094 - 1095
  • [6] A randomised controlled trial comparing the GlideScope® and the Macintosh laryngoscope for double-lumen endobronchial intubation
    Russell, T.
    Slinger, P.
    Roscoe, A.
    McRae, K.
    Van Rensburg, A.
    ANAESTHESIA, 2013, 68 (12) : 1253 - 1258
  • [7] Comparison of Airtraq with Macintosh Laryngoscope for Endotracheal Intubation in Paediatric Patients: A Randomised Controlled Trial
    Dwivedi, Yogita
    Jain, Ankit
    Yadav, Vijay Pratap
    Agarwal, Atiharsh Mohan
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2022, 16 (03) : UC16 - UC18
  • [8] A randomised comparative study of the effect of Airtraq optical laryngoscope vs. Macintosh laryngoscope on intraocular pressure in non-ophthalmic surgery
    Das, Bikramjit
    Samal, Rajiv Kumar
    Ghosh, Arup
    Kundu, Ratul
    REVISTA BRASILEIRA DE ANESTESIOLOGIA, 2016, 66 (01): : 19 - 23
  • [9] HEMODYNAMIC RESPONSES TO TRACHEAL INTUBATION USING DOUBLE-LUMEN TUBES: A RANDOMIZED TRIAL COMPARING THE AIRTRAQ™ AND THE MACINTOSH LARYNGOSCOPE
    Stumpner, T.
    Hager, H.
    Grubhofer, G.
    Kamp, T.
    INTENSIVE CARE MEDICINE, 2011, 37 : S88 - S88
  • [10] A comparison of tracheal intubation using the Airtraq® or the Macintosh laryngoscope in routine airway management:: a randomised, controlled clinical trial
    Maharaj, C. H.
    O'Croinin, D.
    Curley, G.
    Harte, B. H.
    Laffey, J. G.
    ANAESTHESIA, 2006, 61 (11) : 1093 - 1099