The Use of CR-39 Detectors in LENR Experiments

被引:0
|
作者
Mosier-Boss, P. A. [1 ]
Forsley, L. P. G. [2 ]
McDaniel, P. J. [3 ]
机构
[1] MIT, Elect Res Lab, Cambridge, MA 02139 USA
[2] JWK Int Corp, Annandale, VA 22003 USA
[3] Univ New Mexico, Albuquerque, NM 87131 USA
来源
JOURNAL OF CONDENSED MATTER NUCLEAR SCIENCE | 2014年 / 14卷
关键词
Charged particles; CR-39; Neutrons; Real-time electronic detectors;
D O I
暂无
中图分类号
O469 [凝聚态物理学];
学科分类号
070205 ;
摘要
In this communication, the use of CR-39 detectors to detect energetic charged particles and neutrons in LENR experiments is discussed. The main advantages of these detectors over real-time electronic detectors are its integration capability and its ability to speciate energetic particles. Unlike real-time detectors, CR-39 can be placed in close proximity to the cathode and can be used for both electrolysis experiments and gas loading. These advantages of CR-39 detectors over real time, electronic detectors are particularly important when energetic particle emissions occur either sporadically in bursts or at a low flux. (C) 2014 ISCMNS. All rights reserved.
引用
收藏
页码:29 / 49
页数:21
相关论文
共 50 条
  • [31] MEASUREMENTS OF RADON IN DWELLINGS WITH CR-39 TRACK DETECTORS.
    Majborn, B.
    Nuclear tracks, 1985, 12 (1-6): : 763 - 766
  • [32] Application of CR-39 detectors in spent reactor fuel assay
    Tam, NC
    Baricza, K
    Lakosi, L
    RADIATION MEASUREMENTS, 1997, 28 (1-6) : 781 - 784
  • [33] Neutron spectrometry using CR-39 track etch detectors
    Phillips, Gary W.
    Spann, Jerrette E.
    Bogard, James S.
    VoDinh, Tuan
    Emfietzoglou, Dimitris
    Devine, Robert T.
    Moscovitch, Marko
    RADIATION PROTECTION DOSIMETRY, 2006, 120 (1-4) : 457 - 460
  • [34] Particularization of alpha contamination using CR-39 track detectors
    M. F. Zaki
    Y. H. El-Shaer
    Pramana, 2007, 69 : 567 - 574
  • [35] STUDIES ON NITROGEN MAPPING BY VARIOUS CR-39 TRACK DETECTORS
    SOMOGYI, G
    VARGA, Z
    HUNYADI, I
    FREYER, K
    TREUTLER, HC
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1986, 12 (1-6): : 949 - 952
  • [36] ERROR ANALYSIS FOR PARTICLE IDENTIFICATION IN CR-39 TRACK DETECTORS
    YADAV, JS
    SINGH, RK
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1990, 51 (01): : 69 - 75
  • [37] Particularization of alpha contamination using CR-39 track detectors
    Zaki, M. F.
    El-Shaer, Y. H.
    PRAMANA-JOURNAL OF PHYSICS, 2007, 69 (04): : 567 - 574
  • [38] Calibration and application of CR-39 type nuclear track detectors in plasma focus and other plasma experiments
    Szydlowski, A
    Banaszak, A
    Sadowski, MJ
    Scholz, M
    HIGH TEMPERATURE MATERIAL PROCESSES, 2003, 7 (04): : 569 - 578
  • [39] Fast neutron spectroscopy using CR-39 track detectors
    El-Sersy, AR
    Eman, SA
    Khaled, NE
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2004, 226 (03): : 345 - 350
  • [40] Radon surveys in Ajloun city using CR-39 detectors
    Rabadi, Douha R.
    Abumurad, Khalid M.
    RADIATION MEASUREMENTS, 2008, 43 : S449 - S451