The Use of CR-39 Detectors in LENR Experiments

被引:0
|
作者
Mosier-Boss, P. A. [1 ]
Forsley, L. P. G. [2 ]
McDaniel, P. J. [3 ]
机构
[1] MIT, Elect Res Lab, Cambridge, MA 02139 USA
[2] JWK Int Corp, Annandale, VA 22003 USA
[3] Univ New Mexico, Albuquerque, NM 87131 USA
来源
JOURNAL OF CONDENSED MATTER NUCLEAR SCIENCE | 2014年 / 14卷
关键词
Charged particles; CR-39; Neutrons; Real-time electronic detectors;
D O I
暂无
中图分类号
O469 [凝聚态物理学];
学科分类号
070205 ;
摘要
In this communication, the use of CR-39 detectors to detect energetic charged particles and neutrons in LENR experiments is discussed. The main advantages of these detectors over real-time electronic detectors are its integration capability and its ability to speciate energetic particles. Unlike real-time detectors, CR-39 can be placed in close proximity to the cathode and can be used for both electrolysis experiments and gas loading. These advantages of CR-39 detectors over real time, electronic detectors are particularly important when energetic particle emissions occur either sporadically in bursts or at a low flux. (C) 2014 ISCMNS. All rights reserved.
引用
收藏
页码:29 / 49
页数:21
相关论文
共 50 条
  • [21] A PROTON SHADOW CAMERA USING CR-39 TRACK DETECTORS
    STONE, GF
    CEGLIO, NM
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1984, 8 (1-4): : 605 - 608
  • [22] The possibility of using plastic detectors CR-39 as UV dosimeters
    Shweikani, R
    Raja, G
    Sawaf, AA
    RADIATION MEASUREMENTS, 2002, 35 (04) : 281 - 285
  • [23] LET calibration for CR-39 detectors in different oxygen environments
    Zhou, D.
    Semones, E.
    Weyland, M.
    Benton, E. R.
    RADIATION MEASUREMENTS, 2007, 42 (09) : 1499 - 1506
  • [24] FURTHER INVESTIGATIONS ON NEUTRON ENERGY RESPONSE OF CR-39 DETECTORS
    ALNAJJAR, SAR
    PIESCH, E
    RADIATION PROTECTION DOSIMETRY, 1987, 20 (1-2) : 57 - 61
  • [25] Individual neutron monitoring with CR-39 detectors at an accelerator centre
    Fiechtner, A
    Wernli, C
    RADIATION PROTECTION DOSIMETRY, 1999, 85 (1-4) : 35 - 38
  • [26] XE-136 AND AU-197 ION TRACK REGISTRATION RESPONSE IN CR-39 AND CR-39 (DOP) DETECTORS
    KUMAR, A
    PRASAD, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1994, 93 (03): : 277 - 281
  • [27] Thickness measurements on cell monolayers using CR-39 detectors
    Dörschel, B
    Hermsdorf, D
    Pieck, S
    Starke, S
    Thiele, H
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2002, 187 (04): : 525 - 534
  • [28] Measurements of radon concentration in soil gas by CR-39 detectors
    Mazur, D
    Janik, M
    Loskiewicz, J
    Olko, P
    Swakon, J
    RADIATION MEASUREMENTS, 1999, 31 (1-6) : 295 - 300
  • [29] FURTHER INVESTIGATION ON ELECTROCHEMICALLY ETCHED CR-39 NEUTRON DETECTORS
    AZIMIGARAKANI, D
    TOMMASINO, L
    TORRI, G
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1988, 15 (1-4): : 309 - 312
  • [30] α-Spectroscopy on CR-39 track detectors for the dosimetry of radon daughters
    Mozzo, P.
    Trotti, F.
    Temporin, A.
    Lanciai, M.
    Predicatori, F.
    Righetti, F.
    Tacconi, A.
    Environment International, 1997, 22 (SUPPL. 1):