EVALUATION OF TECHNETIUM-99M-L,L-EC IN RENAL-TRANSPLANT RECIPIENTS - A COMPARATIVE-STUDY WITH TECHNETIUM-99M-MAG3 AND IODINE-125-OIH

被引:0
|
作者
STOFFEL, M
JAMAR, F
VANNEROM, C
VERBRUGGEN, A
MOURAD, M
LENERS, N
SQUIFFLET, JP
BECKERS, C
机构
[1] UNIV CATHOLIQUE LOUVAIN, SCH MED, DIV RENAL TRANSPLANTAT, B-1200 BRUSSELS, BELGIUM
[2] KATHOLIEKE UNIV LEUVEN, FFW, RADIOPHARMACEUT CHEM LAB, B-3001 LOUVAIN, BELGIUM
关键词
LLEC; MAG3; ERPF; TUBULAR TRACER; KIDNEY TRANSPLANT;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The clinical usefulness of kit-formulated (TC)-T-99m-L,L-EC, a new renal tubular tracer agent based on a diaminodithiol ligand was evaluated in a large population of renal transplant recipients. Methods: Fifty patients with transplants were studied. Five patients with renal insufficiency and five normal volunteers were also included to extend the range of renal function values. The labeling efficiency of Tc-99m-L,L-EC in routine conditions, i.e., without HPLC purification, and the safety of the tracer were evaluated. Results: The mean radiochemical purity of Tc-99m-L,L-EC determined by thin-layer chromatography was 97.4%. No side effects or significant biochemical changes were observed. The clearance of Tc-99m-L,L-EC and I-125-OIH ranged from 10.7 to 417.5 and from 27.6 to 602.7 ml/min/1.73 m(2), respectively The clearance of Tc-99m-L,L-EC and Tc-99m-MAG3 averaged respectively 71% and 52% of that of I-125-OIH. Conclusion: The labeling procedure of kit-formulated Tc-99m-L,L-EC is easy and efficient. This tracer is safe and suitable for both imaging and quantitative measurement of the renal tubular function. Technetium-99m-L,L-EC represents an excellent alternative to Tc-99m-MAG3.
引用
收藏
页码:1951 / 1958
页数:8
相关论文
共 40 条
  • [1] CLINICAL COMPARISON OF TECHNETIUM-99M-EC, TECHNETIUM-99M-MAG3 AND IODINE-131-OIH IN RENAL DISORDERS
    KABASAKAL, L
    TUROGLU, HT
    ONSEL, C
    OZKER, K
    USLU, I
    ATAY, S
    CANSIZ, T
    SONMEZOGLU, K
    ALTIOK, E
    ISITMAN, AT
    KAPICIOGLU, T
    URGANCIOGLU, I
    JOURNAL OF NUCLEAR MEDICINE, 1995, 36 (02) : 224 - 228
  • [2] TECHNETIUM-99M-N,N-ETHYLENEDICYSTEINE - A COMPARATIVE-STUDY OF RENAL SCINTIGRAPHY WITH TECHNETIUM-99M-MAG3 AND IODINE-131-OIH IN PATIENTS WITH OBSTRUCTIVE RENAL-DISEASE
    OZKER, K
    ONSEL, C
    KABASAKAL, L
    SAYMAN, HB
    USLU, I
    BOZLUOLCAY, S
    CANSIZ, T
    KAPICIOGLU, T
    URGANCIOGLU, I
    JOURNAL OF NUCLEAR MEDICINE, 1994, 35 (05) : 840 - 845
  • [3] RADIATION-DOSIMETRY FOR TECHNETIUM-99M-MAG3, TECHNETIUM-99M-DTPA, AND IODINE-131-OIH BASED ON HUMAN BIODISTRIBUTION STUDIES
    STABIN, M
    TAYLOR, A
    ESHIMA, D
    WOOTER, W
    JOURNAL OF NUCLEAR MEDICINE, 1992, 33 (01) : 33 - 40
  • [4] A COMPARATIVE-STUDY OF RENAL SCINTIGRAPHY AND CLEARANCE WITH TECHNETIUM-99M-MAG3 AND IODINE-123-HIPPURATE IN PATIENTS WITH RENAL DISORDERS
    MULLERSUUR, R
    BOISSVENSSON, I
    MESKO, L
    JOURNAL OF NUCLEAR MEDICINE, 1990, 31 (11) : 1811 - 1817
  • [5] RENAL CLEARANCE OF TECHNETIUM-99M-MAG3 - NORMAL VALUES
    RUSSELL, CD
    LI, Y
    KAHRAMAN, HN
    DUBOVSKY, EV
    JOURNAL OF NUCLEAR MEDICINE, 1995, 36 (04) : 706 - 708
  • [6] Measurement of renal function with technetium-99m-MAG3 in children and adults
    Russell, CD
    Taylor, AT
    Dubovsky, EV
    JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (04) : 588 - 593
  • [7] Technetium-99m-L,L-ethylenedicysteine renal scan as a single-modality investigation for the evaluation of renal morphology and function: a comparative study with technetium-99m-dimercaptosuccinic acid
    Narayana, C
    Tripathi, M
    Kumar, A
    Gowda, NK
    Phom, H
    Chandra, P
    Bandopadhyaya, G
    Bal, C
    NUCLEAR MEDICINE COMMUNICATIONS, 2004, 25 (07) : 743 - 747
  • [8] Preparation and biological evaluation of technetium-99m-L,L-propylenedicysteine
    Dezutter, NA
    de Groot, TJ
    Vanbilloen, HP
    Janssen, GA
    Verbruggen, AM
    JOURNAL OF LABELLED COMPOUNDS & RADIOPHARMACEUTICALS, 1999, 42 (06): : 553 - 565
  • [9] Technetium-99m-MAG3 and technetium-99m-DTPA: Renal clearance measured by the constant infusion technique - Old news?
    Ostergaard, Ann Mai
    Langaa, Stine S.
    Vrist, Marie H.
    Mose, Frank H.
    Bech, Jesper N.
    Fynbo, Claire A.
    Theil, Jorn
    Ejlersen, June A.
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2021, 41 (06) : 488 - 496
  • [10] TECHNETIUM-99M-MAG3 VERSUS IODINE-123-OIH - RENAL CLEARANCE AND DISTRIBUTION VOLUME AS MEASURED BY A CONSTANT INFUSION TECHNIQUE
    PRENEN, JAC
    DEKLERK, JMH
    SCHIP, ADV
    VANRIJK, PP
    JOURNAL OF NUCLEAR MEDICINE, 1991, 32 (11) : 2057 - 2060