摘要
The clinical usefulness of kit-formulated (TC)-T-99m-L,L-EC, a new renal tubular tracer agent based on a diaminodithiol ligand was evaluated in a large population of renal transplant recipients. Methods: Fifty patients with transplants were studied. Five patients with renal insufficiency and five normal volunteers were also included to extend the range of renal function values. The labeling efficiency of Tc-99m-L,L-EC in routine conditions, i.e., without HPLC purification, and the safety of the tracer were evaluated. Results: The mean radiochemical purity of Tc-99m-L,L-EC determined by thin-layer chromatography was 97.4%. No side effects or significant biochemical changes were observed. The clearance of Tc-99m-L,L-EC and I-125-OIH ranged from 10.7 to 417.5 and from 27.6 to 602.7 ml/min/1.73 m(2), respectively The clearance of Tc-99m-L,L-EC and Tc-99m-MAG3 averaged respectively 71% and 52% of that of I-125-OIH. Conclusion: The labeling procedure of kit-formulated Tc-99m-L,L-EC is easy and efficient. This tracer is safe and suitable for both imaging and quantitative measurement of the renal tubular function. Technetium-99m-L,L-EC represents an excellent alternative to Tc-99m-MAG3.
引用
收藏
页码:1951 / 1958
页数:8
相关论文
共 40 条
  • [31] Technetium-99m-MAG3 renal studies in spinal cord injury patients: Normal range, reproducibility, and change as a function of duration and level of injury
    Klingensmith, WC
    Lammertse, DP
    Briggs, DE
    Smith, WI
    Roberts, JF
    Froelich, JW
    Sutherland, JD
    SPINAL CORD, 1996, 34 (06) : 338 - 345
  • [32] Evaluation of renal function after laparoscopic partial nephrectomy by using 99m technetium-mercaptoacetyltriglycine (99m Tc-MAG3) renography
    Terachi, Toshiro
    Kobayashi, Yasuyuki
    Usui, Yukio
    Shima, Masanori
    Hyochi, Nobuhiko
    Hanai, Tadashi
    Hoshi, Akio
    Hanai, Kazuya
    JOURNAL OF ENDOUROLOGY, 2006, 20 : A209 - A209
  • [33] TC-99M MAG3 AS AN ALTERNATIVE TO TC-99M DTPA AND I-131 HIPPURAN FOR RENAL-TRANSPLANT EVALUATION
    OMALLEY, JP
    ZIESSMAN, HA
    CHANTARAPITAK, N
    CLINICAL NUCLEAR MEDICINE, 1993, 18 (01) : 22 - 29
  • [34] EFFECTS OF ALTERED PHYSIOLOGIC STATES ON CLEARANCE AND BIODISTRIBUTION OF TECHNETIUM-99M MAG3, I-131 OIH, AND I-125 IOTHALAMATE
    TAYLOR, A
    ESHIMA, D
    JOURNAL OF NUCLEAR MEDICINE, 1988, 29 (05) : 669 - 675
  • [35] TECHNETIUM-99M LABELED RENAL-FUNCTION AND IMAGING AGENTS .2. CLINICAL-EVALUATION OF TC-99M MAG3 (TC-99M MERCAPTOACETYLGLYCYLGLYCYLGLYCINE)
    BUBECK, B
    BRANDAU, W
    STEINBACHER, M
    REINBOLD, F
    DREIKORN, K
    EISENHUT, M
    GEORGI, P
    NUCLEAR MEDICINE AND BIOLOGY, 1988, 15 (01): : 109 - 118
  • [36] Clearance and renal extraction of technetium-99m-L,L-ethylenedicysteine, I-131-ortho-iodohippurate and I-125-iothalamate in pigs (vol 19, pg 338, 1999)
    Nielsen, SS
    Poulsen, EU
    Marqversen, J
    Nielsen, LE
    Bacher, T
    Rehling, M
    CLINICAL PHYSIOLOGY, 1999, 19 (06): : 527 - 527
  • [37] The value of different washout parameters in the evaluation of renal transplants by technetium-99m-ethylene-l-l-dicysteine (vol 13, pg 127, 2010)
    Kanmaz, Bedii
    HELLENIC JOURNAL OF NUCLEAR MEDICINE, 2010, 13 (03): : 288 - 288
  • [38] COMPARATIVE-STUDY OF THE KINETICS OF THE RENAL TRACERS TC-99 M-MAG3 AND I-131 HIPPURAN
    PAVIA, J
    ROS, D
    PIERA, C
    PAVIA, A
    BASSA, P
    GIRALT, E
    SETOAIN, J
    NUCLEAR MEDICINE COMMUNICATIONS, 1991, 12 (06) : 529 - 537
  • [39] A COMPARATIVE-STUDY OF RENAL SCINTIGRAPHY AND CLEARANCE WITH TC-99M MAG-3 AND 123-I HIPPURATE IN PATIENTS WITH RENAL DISORDERS
    MULLERSUUR, R
    BOISSVENSSON, I
    MESKO, L
    JOURNAL OF NUCLEAR MEDICINE, 1989, 30 (04) : AB2 - AB2
  • [40] Optimizing input parameter of the randomized singular value decomposition algorithm for compressing technetium-99m L,L, ethylenedicysteine renal dynamic study in minimum time preserving clinical information
    Chaudhary, Jagrati
    Pandey, Anil Kumar
    Sharma, Param D.
    Patel, Chetan
    Kumar, Rakesh
    NUCLEAR MEDICINE COMMUNICATIONS, 2022, 43 (12) : 1171 - 1180