CLINICAL COMPARISON OF TECHNETIUM-99M-EC, TECHNETIUM-99M-MAG3 AND IODINE-131-OIH IN RENAL DISORDERS

被引:0
|
作者
KABASAKAL, L [1 ]
TUROGLU, HT [1 ]
ONSEL, C [1 ]
OZKER, K [1 ]
USLU, I [1 ]
ATAY, S [1 ]
CANSIZ, T [1 ]
SONMEZOGLU, K [1 ]
ALTIOK, E [1 ]
ISITMAN, AT [1 ]
KAPICIOGLU, T [1 ]
URGANCIOGLU, I [1 ]
机构
[1] UNIV ISTANBUL,CERRAHPASA MED FAC,DEPT NUCL MED,ISTANBUL,TURKEY
关键词
IODINE-131-OIH; TECHNETIUM-99M-MAG3; TECHNETIUM-99M-EC; RENAL FUNCTION; RENAL IMAGING;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Technetium-99m-ethylenedicysteine has recently been developed for renal function studies. The pharmacokinetics of Tc-99m-EC were studied by constant infusion technique and compared with Tc-99m-MAG3 and I-131-OIH in, 11 patients with various renal disorders. Methods: After giving a 7.4 MBq I-131-OIH and 90-110 MBq Tc-99m-EC or Tc-99m-MAG3 bolus, a constant infusion (1 MBq/ml Tc-99m-agent and 0.07 MBq/m I-131-OIH was started. Sixteen blood and five urine samples were obtained over three hr. Results: The renal clearance of Tc-99m-EC was higher than that of Tc-99m-MAG3. The Tc-99m-EC/OIH and (99m)TcMAG3/OIH ratios were 0.75 +/- 0.05 and 0.55 +/- 0.10 (p = 0.00087), respectively. The distribution volume of Tc-99m-EC was also higher than that of Tc-99m-MAG3 (15722 +/- 4644 and 9509 +/- 2788 m1/1.73m(2), respectively; p = 0.072). The Tc-99m-EC/OIH and Tc-99m-MAG3/OIH distribution volume ratios were 1.03 +/- 0.14 and 0.55 +/- 0.10, respectively (p = 0.0003). The 60-min excretion values of Tc-99m-EC and Tc-99m-MAG3 were compared to that of OIH. The Tc-99m-EC/OIH and Tc-99m-MAG3/OIH excretion ratios were 0.96 +/- 0.06 and 1.07 +/- 0.10, respectively (p = 0.162). The protein binding of Tc-99m-EC and OIH were found to be 34% +/- 4 and 66% +/- 5, respectively (p < 0.0001). The red cell binding of Tc-99m-EC was negligible (3% +/- 1.2) in comparison to OIH (27% +/- 3; p < 0.0001). Conclusion: This limited study demonstrates the pharmacokinetic and renal clearance properties of Tc-99m-EC. This agent has good potential for renal function evaluation.
引用
收藏
页码:224 / 228
页数:5
相关论文
共 50 条
  • [1] RADIATION-DOSIMETRY FOR TECHNETIUM-99M-MAG3, TECHNETIUM-99M-DTPA, AND IODINE-131-OIH BASED ON HUMAN BIODISTRIBUTION STUDIES
    STABIN, M
    TAYLOR, A
    ESHIMA, D
    WOOTER, W
    JOURNAL OF NUCLEAR MEDICINE, 1992, 33 (01) : 33 - 40
  • [2] TECHNETIUM-99M-N,N-ETHYLENEDICYSTEINE - A COMPARATIVE-STUDY OF RENAL SCINTIGRAPHY WITH TECHNETIUM-99M-MAG3 AND IODINE-131-OIH IN PATIENTS WITH OBSTRUCTIVE RENAL-DISEASE
    OZKER, K
    ONSEL, C
    KABASAKAL, L
    SAYMAN, HB
    USLU, I
    BOZLUOLCAY, S
    CANSIZ, T
    KAPICIOGLU, T
    URGANCIOGLU, I
    JOURNAL OF NUCLEAR MEDICINE, 1994, 35 (05) : 840 - 845
  • [3] EVALUATION OF TECHNETIUM-99M-L,L-EC IN RENAL-TRANSPLANT RECIPIENTS - A COMPARATIVE-STUDY WITH TECHNETIUM-99M-MAG3 AND IODINE-125-OIH
    STOFFEL, M
    JAMAR, F
    VANNEROM, C
    VERBRUGGEN, A
    MOURAD, M
    LENERS, N
    SQUIFFLET, JP
    BECKERS, C
    JOURNAL OF NUCLEAR MEDICINE, 1994, 35 (12) : 1951 - 1958
  • [4] PHARMACOKINETICS OF TECHNETIUM-99M-MAG3 IN HUMANS
    BUBECK, B
    BRANDAU, W
    WEBER, E
    KALBLE, T
    PAREKH, N
    GEORGI, P
    JOURNAL OF NUCLEAR MEDICINE, 1990, 31 (08) : 1285 - 1293
  • [5] RENAL CLEARANCE OF TECHNETIUM-99M-MAG3 - NORMAL VALUES
    RUSSELL, CD
    LI, Y
    KAHRAMAN, HN
    DUBOVSKY, EV
    JOURNAL OF NUCLEAR MEDICINE, 1995, 36 (04) : 706 - 708
  • [6] COMPARISON OF THE CLEARANCE OF TECHNETIUM-99M MAG3 AND I-131 OIH
    KIM, CK
    STRITZKE, P
    GOLDSMITH, SJ
    JOURNAL OF NUCLEAR MEDICINE, 1988, 29 (11) : 1878 - 1878
  • [7] Measurement of renal function with technetium-99m-MAG3 in children and adults
    Russell, CD
    Taylor, AT
    Dubovsky, EV
    JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (04) : 588 - 593
  • [8] Background subtraction in technetium-99m-MAG3 renography
    Taylor, A
    Thakore, K
    Folks, R
    Halkar, R
    Manatunga, A
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (01) : 74 - 79
  • [9] Prediction of urinary excretion of technetium-99m-MAG3
    Russell, CD
    Dubovsky, EV
    Taylor, AT
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (07) : 1257 - 1259
  • [10] Technetium-99m-MAG3 and technetium-99m-DTPA: Renal clearance measured by the constant infusion technique - Old news?
    Ostergaard, Ann Mai
    Langaa, Stine S.
    Vrist, Marie H.
    Mose, Frank H.
    Bech, Jesper N.
    Fynbo, Claire A.
    Theil, Jorn
    Ejlersen, June A.
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2021, 41 (06) : 488 - 496