THORACOSCOPIC PLACEMENT OF IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR PATCH LEADS IN SHEEP

被引:0
|
作者
BIELEFELD, MR [1 ]
YANO, OJ [1 ]
CABRERIZA, SE [1 ]
TREAT, MR [1 ]
KIRBY, TJ [1 ]
SPOTNITZ, HM [1 ]
机构
[1] COLUMBIA UNIV COLL PHYS & SURG,DEPT SURG,630 W 168TH ST,NEW YORK,NY 10032
关键词
THORACOSCOPY; ASSIST DEVICES; LAPAROSCOPY;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. A thoracoscopic technique was developed for the placement of commercially available implantable cardioverter-defibrillator (ICD) patch leads in sheep. Methods and Results. Small ICD patch leads (13.5 cm2, A-67) were placed thoracoscopically in sheep (n=5) that had survived coronary artery ligation from a previous experiment. The technique used three small incisions in the left chest. After lysis of adhesions, the ICD patch lead was introduced through a mediastinoscope. The ICD patch lead was secured in the extrapericardial position with surgical clips placed in the four corners of the ICD patch lead. After 2 weeks, a median sternotomy was performed, and ICD patch leads were reexamined for positioning. Extensive fibrosis was noted to adhere the ICD patch lead to the pericardium. The surgical clips were found intact in all animals without noticeable migration of patch lead position. There was no mortality related to ICD patch lead placement, and estimated blood loss was less than 30 mL without use of cautery. Conclusions. Commercially available ICD patch leads may be reliably and safely placed with minimal patch migration in sheep using thoracoscopic techniques.
引用
收藏
页码:447 / 451
页数:5
相关论文
共 50 条
  • [1] LAPAROSCOPIC PLACEMENT OF IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR LEADS IN SHEEP
    BIELEFELD, MR
    YANO, OJ
    CABRERIZA, SE
    TREAT, MR
    KIRBY, TJ
    SPOTNITZ, HM
    CIRCULATION, 1992, 86 (04) : 569 - 569
  • [2] Intramural migration of implantable cardioverter-defibrillator patch
    Wolfhard, U
    Splittgerber, FH
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1996, 111 (03): : 681 - 681
  • [3] Extraction of endocardial implantable cardioverter-defibrillator leads
    Le Franc, P
    Klug, D
    Jarwe, M
    Lacroix, D
    Delfaut, P
    Kouakam, C
    Kacet, S
    AMERICAN JOURNAL OF CARDIOLOGY, 1999, 84 (02): : 187 - 191
  • [4] Migration of implantable cardioverter-defibrillator patch into the right atrium
    Mulero, E
    Karanam, RN
    Krol, R
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1997, 113 (05): : 951 - 952
  • [5] Risk of Failure of Transvenous Implantable Cardioverter-Defibrillator Leads
    Borleffs, C. Jan Willem
    van Erven, Lieselot
    van Bommel, Rutger J.
    van der Velde, Enno T.
    van der Wall, Ernst E.
    Bax, Jeroen J.
    Rosendaal, Frits R.
    Schalij, Martin J.
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2009, 2 (04): : 411 - 416
  • [6] Insulation Defects in Riata Implantable Cardioverter-defibrillator Leads
    Sato, Akinori
    Chinushi, Masaomi
    Iijima, Kenichi
    Izumi, Daisuke
    Furushima, Hiroshi
    INTERNAL MEDICINE, 2012, 51 (19) : 2689 - 2694
  • [7] IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR PATCH EROSION PRESENTING AS HEMOPTYSIS
    VERHEYDEN, CN
    PRICE, L
    LYNCH, DJ
    KNIGHT, WL
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1994, 5 (11) : 961 - 963
  • [8] Implantable Cardioverter-Defibrillator Leads Design, Diagnostics, and Management
    Swerdlow, Charles D.
    Ellenbogen, Kenneth A.
    CIRCULATION, 2013, 128 (18) : 2062 - 2071
  • [9] Effect of Left Ventricular Assist Device Placement on Preexisting Implantable Cardioverter-defibrillator Leads
    Ambardekar, Amrut V.
    Lowery, Christopher M.
    Allen, Larry A.
    Cannon, Anne P.
    Cleveland, Joseph C., Jr.
    Lindenfeld, Joann
    Brieke, Andreas
    Sauer, William H.
    JOURNAL OF CARDIAC FAILURE, 2010, 16 (04) : 327 - 331
  • [10] Learning From Implantable Cardioverter-Defibrillator Leads in Children
    Rottman, Jeff
    CIRCULATION, 2013, 127 (24) : 2370 - 2371