An Anatomical Study to Demonstrate the Proximity of Kirschner Wires to Structures at Risk in Percutaneous Pinning of Distal Radius Fractures

被引:4
|
作者
Santoshi, John A. [1 ]
Chaware, Prashant N. [2 ]
Pakhare, Abhijit P. [3 ]
Rathinam, Bertha A. D. [2 ]
机构
[1] AIIMS, Dept Orthopaed, Bhopal 462020, MP, India
[2] AIIMS, Dept Anat, Bhopal 462020, MP, India
[3] AIIMS, Dept Community & Family Med, Bhopal 462020, MP, India
关键词
Distal radius; Percutaneous; Kirschnerwire; Complication; Superficial radial nerve; Lateral cutaneous nerve of forearm; Dorsal branch of ulnar nerve; Cephalic vein; Radial artery;
D O I
10.1007/s12593-015-0181-7
中图分类号
R61 [外科手术学];
学科分类号
摘要
Distal radius fractures are often treated using percutaneous Kirschner wires (K-wires). The sensory nerves in this area, extensor tendons, radial artery and cephalic vein are at risk of injury in this procedure. We undertook a cadaveric investigation to identify probability of damage to these 'at risk' structures by measuring their distances in relation to standard K-wire sites. Nine upper limbs from six formalinpreserved cadavers were studied. Four K-wires were placed percutaneously simulating fixation of a distal radius fracture. Careful dissectionwas done preserving the original position of neurovascular and tendinous structures. Distances to relevant soft-tissue structures from each K-wire were measured using an electronic digital caliper. Distance of superficial nerves from radial styloid and Lister's tubercle was measured to determine their 'safe distance' from these fixed landmarks. None of the superficial nerves were injured by a K-wire. Cephalic vein had been pierced on 4 occasions (4/18) and extensor tendons on 3 occasions (3/18). Wilcoxon signed-rank test was used to compare distance of the superficial nerves from radial styloid and Lister tubercle, and the latter was found to be the safer option. This study highlights the inherent danger in percutaneous K-wire fixation of wrist fractures. Limited size of the area, where K-wires can be positioned, and anatomic variations of neurovascular structures pose obstacles in developing guidelines for reducing risk of injury. We advocate use of mini-open approach and guiding devices to avert complications of inadvertent impalement and damage to these structures.
引用
收藏
页码:73 / 78
页数:6
相关论文
共 50 条
  • [41] PERCUTANEOUS KIRSCHNER-WIRE PINNING FOR SEVERELY DISPLACED DISTAL RADIAL FRACTURES IN CHILDREN - A REPORT OF 157 CASES
    CHOI, KY
    CHAN, WS
    LAM, TP
    CHENG, JCY
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1995, 77 (05): : 797 - 801
  • [42] Long-Term Outcomes of Closed Reduction and Percutaneous Pinning for the Treatment of Distal Radius Fractures
    van Aaken, Jan
    Beaulieu, Jean-Yves
    Fusetti, Cesare
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2009, 34A (05): : 963 - 963
  • [43] Is percutaneous pinning needed for the treatment of displaced distal radius metaphyseal fractures in children? A systematic review
    Zeng, Zhi-Kui
    Liang, Wei-Dong
    Sun, You-Qiang
    Jiang, Ping-Pin
    Li, Ding
    Shen, Zhen
    Yuan, Ling-Mei
    Huang, Feng
    MEDICINE, 2018, 97 (36)
  • [44] Long-Term Outcomes of Closed Reduction and Percutaneous Pinning for the Treatment of Distal Radius Fractures
    Glickel, Steven Z.
    Catalano, Louis W.
    Raia, Frank J.
    Barron, O. Alton
    Grabow, Ryan
    Chia, Benjamin
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2008, 33A (10): : 1700 - 1705
  • [45] SAFE PERCUTANEOUS PINNING FOR SUBCAPITAL FIFTH METACARPAL FRACTURES: AN ANATOMICAL STUDY
    Polat, Onur
    Comert, Ayhan
    Atalar, Hakan
    Acar, Halil Ibrahim
    Tuccar, Eray
    ACTA ORTOPEDICA BRASILEIRA, 2011, 19 (02): : 106 - 109
  • [46] RADIOLOGICAL OUTCOMES OF DISTAL RADIUS EXTRA-ARTICULAR FRAGILITY FRACTURES TREATED WITH EXTRA-FOCAL KIRSCHNER WIRES
    Kennedy, C.
    Kennedy, M. T.
    Niall, D.
    Devitt, A.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2010, 179 : 40 - 40
  • [47] The outcomes of displaced paediatric distal radius fractures treated with percutaneous Kirschner wire fixation: a review of 248 cases
    Ramoutar D.N.
    Shivji F.S.
    Rodrigues J.N.
    Hunter J.B.
    European Journal of Orthopaedic Surgery & Traumatology, 2015, 25 (3) : 471 - 476
  • [48] Radiological outcomes of distal radius extra-articular fragility fractures treated with extra-focal kirschner wires
    Kennedy, C.
    Kennedy, M. T.
    Niall, D.
    Devitt, A.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2010, 41 (06): : 639 - 642
  • [49] Displaced paediatric distal radius fractures-When should we use percutaneous wires?
    Jordan, R. W.
    Westacott, D. J.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2012, 43 (06): : 908 - 911
  • [50] Bioresorbable implants vs. Kirschner-wires in the treatment of severely displaced distal paediatric radius and forearm fractures - a retrospective multicentre study
    Varga, Marcell
    Jozsa, Gergo
    Hanna, Daniel
    Toth, Mate
    Hajnal, Bence
    Krupa, Zsofia
    Kassai, Tamas
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)