Bioresorbable implants vs. Kirschner-wires in the treatment of severely displaced distal paediatric radius and forearm fractures - a retrospective multicentre study

被引:8
|
作者
Varga, Marcell [1 ]
Jozsa, Gergo [2 ]
Hanna, Daniel [2 ]
Toth, Mate [3 ]
Hajnal, Bence [4 ]
Krupa, Zsofia [4 ]
Kassai, Tamas [1 ]
机构
[1] Dr Manninger Jeno Baleseti Kozpont, Budapest, Hungary
[2] Univ Pecs, Med Sch, Pecs, Hungary
[3] Szegedi Tud Egyet Altalanos, Orvostud Kar, Szeged, Hungary
[4] Szent Janos Korhaz, Budapest, Hungary
关键词
INTERNAL-FIXATION; POLYGLYCOLIDE; COMPLICATIONS; CHILDREN; REMOVAL; TRIAL; NAILS;
D O I
10.1186/s12891-022-05305-w
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Distal radius fractures are very common in paediatric patients. Severely displaced fractures may require surgical intervention. The gold standard surgical method is percutaneous K-wire osteosynthesis followed by immobilisation. Metal implants can be removed with a second intervention; however, these extra procedures can cause further complications. Several studies confirm the benefits of bioabsorbable implants for paediatric patients. The aim of this retrospective study was to compare the complication rates of displaced distal metaphyseal radius (AO 23r-M/3.1) and forearm (AO 23-M/3.1) fractures in children operated on with K-wires versus a novel technique with bioresorbable implants. Methods: We retrospectively reviewed 94 patients in three paediatric trauma centres who underwent operations due to severely displaced distal forearm or metaphyseal radial fractures between January 2019 and January 2020. The mean age was 8.23 (ranging from 5-12). 30 patients (bioresorbable group, BR-group) were treated with biodegradable PLGA implants (Bioretec (R), ActivaPin (R)), 40 patients with one or two stainless steel Kirschner-wires (K-wires, Sanatmetal (R)) which were buried under the skin (KW I-group) and 24 children with K-wires left outside the skin. (KWII. Group). We examined the number of minor and major complications as well as the need for repeated interventions. Follow-up was at least one and half year. Results: There was no significant difference between the complication rates at the two KW groups (p = 0.241; Cramer's V = 0.211), while the complication rate of the BR group was significantly lower. (p = 0.049; Cramer's V = 0.293 and p = 0.002; Cramer's V = 0.418 respectively). No later than half a year after the injury, no difference was observed between the functional outcomes of the patients in each group. One and a half years after the injury, no signs of growth disturbance were found in any of the children. No second surgical intervention was required in the BR group. Conclusions: Surgeries with bioresorbable intramedullary implants may have fewer complications than K-wire osteosynthesis in the treatment of severely displaced distal forearm fractures. The benefits are most pronounced in the first six weeks after surgery, reducing the number of outpatient visits and increasing the child's sense of comfort. As no second intervention is required, this can lead to significant cost savings. After half a year, there is no difference in the outcomes between the different surgical treatment strategies.
引用
收藏
页数:9
相关论文
共 7 条
  • [1] Bioresorbable implants vs. Kirschner-wires in the treatment of severely displaced distal paediatric radius and forearm fractures – a retrospective multicentre study
    Marcell Varga
    Gergő Józsa
    Dániel Hanna
    Máté Tóth
    Bence Hajnal
    Zsófia Krupa
    Tamás Kassai
    BMC Musculoskeletal Disorders, 23
  • [2] Treatment of distal radius fractures Percutaneous Kirschner-wires or palmar locking plates?
    Meier, R.
    Krettek, C.
    Probst, C.
    UNFALLCHIRURG, 2012, 115 (07): : 598 - 605
  • [3] Nonoperative treatment of distal radius fractures and forearm rotation in elderly patients: a retrospective study
    Liao, Janice C. Y.
    Cheah, Andre E. J.
    Chong, Alphonsus K. S.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2020, 45 (07) : 761 - 763
  • [4] A comparative study of functional outcome of treatment of intra articular fractures of distal radius fixed with percutaneous Kirschner's wires vs T-plate
    Khan, Jahangir Iqbal
    Hussain, Faisal Nazeer
    Mehmood, Tahir
    Adil, Omer
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2017, 33 (03) : 709 - 713
  • [5] Predictors of limited forearm rotation following conservative treatment of distal radius fractures: a retrospective comparative study
    Li, Chenfei
    Ye, Jiaqing
    Lu, Jian
    Guo, Tianhao
    Kong, Lingde
    Zhang, Bing
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
  • [6] Is casting of displaced paediatric distal forearm fractures non-inferior to reduction under general anaesthesia? Study protocol for a pragmatic, randomized, controlled non-inferiority multicentre trial (the casting trial)
    Abildgaard, Katrine Ronn
    Buxbom, Peter
    Rahbek, Ole
    Gottliebsen, Martin
    Gundtoft, Per Hviid
    Viberg, Bjarke
    Brorson, Stig
    TRIALS, 2024, 25 (01)
  • [7] Does the AO/OTA fracture classification dictate the anesthesia modality for the surgical management of unstable distal radius fractures? - A retrospective cohort study in 127 patients managed by general vs. regional anesthesia
    Halvachizadeh, Sascha
    Dreifuss, Merav
    Rauer, Thomas
    Kaiser, Anne
    Ubmann, Dirk
    Pape, Hans-Christoph
    Allemann, Florin
    PATIENT SAFETY IN SURGERY, 2025, 19 (01):