IMAGE QUALITY OF DIGITAL CHEST RADIOGRAPHY - EVALUATION OF SUBTLE INTERSTITIAL LUNG ABNORMALITIES - (PRELIMINARY-STUDY)

被引:1
|
作者
IKEZOE, J
KIDO, S
TAKEUCHI, N
KONDOH, H
ARISAWA, J
KOZUKA, T
机构
[1] Department of Radiology, Osaka University Medical School, Suita City, Osaka
关键词
IMAGE QUALITY; DIGITAL RADIOGRAPHY; STORAGE PHOSPHOR RADIOGRAPHY; RECEIVER OPERATING CHARACTERISTIC ANALYSIS;
D O I
10.1016/0169-2607(94)90195-3
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
To evaluate the image quality of storage phosphor radiography (SR) for diagnosing subtle interstitial lung abnormalities, we studied the differences between conventional screen-film radiography (FR) and SR in 38 patients. Nineteen patients had subtle interstitial lung abnormalities and the others had normal chests. Two formats of hard copies were used for SR; a full-size SR (14 x 14 inches, 0.2-mm pixel size) and a minified SR (9 x 9 inches, 0.13-mm pixel size). Readings were carried out by 14 readers (7 chest radiologists and 7 residents). The area under the receiver operating characteristic curve was used to evaluate the results. For the 14 readers no significant differences in observer performance were observed among the three image sets (FR, full-size SR, minified SR), while for the seven chest radiologists significant differences were observed between FR and the two formats of SR. The best perceptual accuracy was obtained with FR as evaluated by the seven chest radiologists. In conclusion, while overall performance with digital and conventional radiographs was almost the same as far as diagnosing subtle interstitial lung abnormalities, significant differences between FR and SR were found by chest radiologists. Critically important information may be lost in commercially available SR.
引用
收藏
页码:107 / 114
页数:8
相关论文
共 50 条
  • [41] The practice of chest radiography using different digital imaging systems: Dose and image quality
    Moey S.-F.
    Shazli Z.A.
    Sayed I.S.
    Iranian Journal of Medical Physics, 2018, 15 (02) : 101 - 107
  • [42] Preliminary study on a chest digital tomosynthesis: development and evaluation
    Lee, Y.
    Lee, S.
    JOURNAL OF INSTRUMENTATION, 2015, 10
  • [43] A case study into the effect of radiographic factors on image quality and dose for a selenium based digital chest radiography system
    Launders, JH
    Cowen, AR
    Bury, RF
    Hawkridge, P
    RADIATION PROTECTION DOSIMETRY, 1998, 80 (1-3) : 279 - 282
  • [44] DIGITAL CHEST RADIOGRAPHY WITH A LARGE IMAGE INTENSIFIER - AN ROC STUDY WITH AN ANTHROPOMORPHIC PHANTOM
    MANSSON, LG
    KHEDDACHE, S
    BORJESSON, J
    MATTSSON, S
    SCHLOSSMAN, D
    EUROPEAN JOURNAL OF RADIOLOGY, 1989, 9 (04) : 208 - 213
  • [45] DIGITAL CHEST RADIOGRAPHY WITH A LARGE IMAGE INTENSIFIER - EVALUATION OF DIAGNOSTIC PERFORMANCE AND PATIENT EXPOSURE
    MANSSON, LG
    KHEDDACHE, S
    SCHLOSSMAN, D
    BORJESSON, J
    HAKANSSON, E
    MATTSSON, S
    TYLEN, U
    ACTA RADIOLOGICA, 1989, 30 (04) : 337 - 342
  • [46] Evaluation of image-quality characteristics of four detectors for digital radiography
    Pooley, RA
    Morin, RL
    Fetterly, KA
    RADIOLOGY, 2001, 221 : 462 - 462
  • [47] Digital radiography image quality evaluation using various phantoms and software
    Tsalafoutas, Ioannis A.
    AlKhazzam, Shady
    Tsapaki, Virginia
    AlNaemi, Huda
    Kharita, Mohammed Hassan
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (12):
  • [48] IMPROVEMENT IN QUALITY-OF-LIFE AFTER LUNG TRANSPLANTATION - A PRELIMINARY-STUDY
    RAMSEY, SD
    PATRICK, DL
    LEWIS, S
    ALBERT, RK
    RAGHU, G
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 1995, 14 (05): : 870 - 877
  • [49] An Evaluation of Image Acquisition Techniques, Radiographic Practice, and Technical Quality in Neonatal Chest Radiography
    Pedersen, Christina Caroe Ejlskov
    Hardy, Maryann
    Blankholm, Anne Dorte
    JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2018, 49 (03) : 257 - 264
  • [50] Optimization of chest radiographic imaging parameters: a comparison of image quality and entrance skin dose for digital chest radiography systems
    Sun, Zhonghua
    Lin, Chenghsun
    Tyan, YeuSheng
    Ng, Kwan-Hoong
    CLINICAL IMAGING, 2012, 36 (04) : 279 - 286