IMAGE QUALITY OF DIGITAL CHEST RADIOGRAPHY - EVALUATION OF SUBTLE INTERSTITIAL LUNG ABNORMALITIES - (PRELIMINARY-STUDY)

被引:1
|
作者
IKEZOE, J
KIDO, S
TAKEUCHI, N
KONDOH, H
ARISAWA, J
KOZUKA, T
机构
[1] Department of Radiology, Osaka University Medical School, Suita City, Osaka
关键词
IMAGE QUALITY; DIGITAL RADIOGRAPHY; STORAGE PHOSPHOR RADIOGRAPHY; RECEIVER OPERATING CHARACTERISTIC ANALYSIS;
D O I
10.1016/0169-2607(94)90195-3
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
To evaluate the image quality of storage phosphor radiography (SR) for diagnosing subtle interstitial lung abnormalities, we studied the differences between conventional screen-film radiography (FR) and SR in 38 patients. Nineteen patients had subtle interstitial lung abnormalities and the others had normal chests. Two formats of hard copies were used for SR; a full-size SR (14 x 14 inches, 0.2-mm pixel size) and a minified SR (9 x 9 inches, 0.13-mm pixel size). Readings were carried out by 14 readers (7 chest radiologists and 7 residents). The area under the receiver operating characteristic curve was used to evaluate the results. For the 14 readers no significant differences in observer performance were observed among the three image sets (FR, full-size SR, minified SR), while for the seven chest radiologists significant differences were observed between FR and the two formats of SR. The best perceptual accuracy was obtained with FR as evaluated by the seven chest radiologists. In conclusion, while overall performance with digital and conventional radiographs was almost the same as far as diagnosing subtle interstitial lung abnormalities, significant differences between FR and SR were found by chest radiologists. Critically important information may be lost in commercially available SR.
引用
收藏
页码:107 / 114
页数:8
相关论文
共 50 条
  • [31] A Technique for Simulating the Effect of Dose Reduction on Image Quality in Digital Chest Radiography
    Wouter J.H. Veldkamp
    Lucia J.M. Kroft
    Jan Pieter A. van Delft
    Jacob Geleijns
    Journal of Digital Imaging, 2009, 22 : 114 - 125
  • [32] OPTIMIZING IMAGE QUALITY, RADIATION DOSAGE TO THE PATIENT AND TO THE DETECTOR IN PEDIATRIC CHEST RADIOGRAPHY: A PHANTOM STUDY OF A PORTABLE DIGITAL RADIOGRAPHY SYSTEM
    Shahgeldi, Kaveh
    Sjoberg, Tommy
    Nordstrom, Jonny
    Lesanu, Radu
    Svahn, Tony Martin
    RADIATION PROTECTION DOSIMETRY, 2019, 185 (04) : 414 - 420
  • [33] DIGITAL RADIOGRAPHY OF SUBTLE PULMONARY ABNORMALITIES - AN ROC STUDY OF THE EFFECT OF PIXEL SIZE ON OBSERVER PERFORMANCE
    MACMAHON, H
    VYBORNY, CJ
    METZ, CE
    DOI, K
    SABETI, V
    SOLOMON, SL
    RADIOLOGY, 1986, 158 (01) : 21 - 26
  • [34] Developing a novel phantom for image quality evaluation in digital radiography
    Yalcin, Asena
    Olgar, Turan
    RADIATION PHYSICS AND CHEMISTRY, 2024, 222
  • [35] Evaluation of Image Quality in Digital Radiography Based On Marginal Detectability
    Scott, A.
    Zhou, Y.
    Zhang, D.
    Binesh, N.
    Lee, C.
    Bosteder, W.
    MEDICAL PHYSICS, 2020, 47 (06) : E534 - E534
  • [36] Image Quality Evaluation of a Digital Radiography System Made in Thailand
    Techavipoo, Udomchai
    Sinsuebphon, Nattawut
    Prompalit, Sakunrat
    Thongvigitmanee, Saowapak
    Narkbuakaew, Walita
    Kiang-ia, Atthasak
    Srivongsa, Tanapon
    Thajchayapong, Pairash
    Chaumrattanakul, Utairat
    BIOMED RESEARCH INTERNATIONAL, 2021, 2021
  • [37] Chest radiography: A comparison of image quality and effective dose using four digital systems
    Pascoal, A
    Lawinski, CP
    Mackenzie, A
    Tabakov, S
    Lewis, CA
    RADIATION PROTECTION DOSIMETRY, 2005, 114 (1-3) : 273 - 277
  • [38] Digital chest radiography: an update on modern technology, dose containment and control of image quality
    Schaefer-Prokop, Cornelia
    Neitzel, Ulrich
    Venema, Henk W.
    Uffmann, Martin
    Prokop, Mathias
    EUROPEAN RADIOLOGY, 2008, 18 (09) : 1818 - 1830
  • [39] Digital chest radiography: an update on modern technology, dose containment and control of image quality
    Cornelia Schaefer-Prokop
    Ulrich Neitzel
    Henk W. Venema
    Martin Uffmann
    Mathias Prokop
    European Radiology, 2008, 18 : 1818 - 1830
  • [40] Correlation between physical measurements and observer evaluations of image quality in digital chest radiography
    Yalcin, Asena
    Olgar, Turan
    Sancak, Tanzer
    Atac, Gokce Kaan
    Akyar, Serdar
    MEDICAL PHYSICS, 2020, 47 (09) : 3935 - 3944